background image

2 Installation

 

❒ Run the bus cable through the large grommet
❒ Fit the holding frame as shown at the desired position in the room using the

anchors and screws provided

➥ The large grommet must be on the right!
➥ It is recommended to install the device above a flush-mounted socket so that

there is plenty of space to stow away the bus cable.

 

2.1 Initial start-up

 

NOTICE

You should have the initial startup carried out by the authorised heating engineer
from Froling customer services.

 

2.1.1 Connecting the bus cable

For the bus connections between the individual modules, cable type 
LIYCY paired 2x2x0.5 should be used. The connection to the 5-pin plugs should be
carried out according to the following diagram:
 

+U

BUS

CAN H

CAN L

+U

BUS

CAN H

CAN L

Braided shield

White

Green

Yellow
Brown

Braided shield

White

Green
Yellow
Brown

 

 

 

Installation

2

Initial start-up

Operating Instructions RBG 3200 Touch | B0780115_en

5

Summary of Contents for RBG 3200 Touch

Page 1: ...iginal German operating instructions for the operator Read and follow the instructions and safety information Technical changes typographical errors and omissions reserved B0780115_en Edition 08 06 2015 Froling GesmbH A 4710 Grieskirchen Industriestraße 12 www froeling com ...

Page 2: ... 4 4 Setting times 13 4 5 Setting the room temperature setpoints 15 4 6 Set the heating circuit mode 15 4 6 1 OFF mode 16 4 6 2 Auto mode 16 4 6 3 Party mode 16 4 6 4 Setback mode 16 5 Menu overview and parameters 17 5 1 Heating 17 5 1 1 Heating Status 17 5 1 2 Heating Temperatures 18 5 1 3 Heating Times 19 5 2 Water 20 5 2 1 Water Status 20 5 2 2 Water Temperatures 21 5 2 3 Water Times 21 5 3 Sol...

Page 3: ...tem Current values 32 5 8 2 System Display operating rights 33 Froling Connect 33 5 9 Diagnostics 34 5 9 1 Diagnostics Error display 34 5 10 Display settings 34 5 10 1 Display settings General 34 Network settings 35 5 10 2 Display settings Date Time 35 6 Troubleshooting 36 6 1 Procedure for fault messages 36 7 FAQ 38 7 1 Updating the software of the touch control 38 7 2 Calibrating the touchscreen...

Page 4: ...pictures and content If you discover any errors please let us know doku froeling com Subject to technical change Froling s RBG 3200 Touch room console is a multifunctional device for convenient operation of the boiler from your living room 1 2 Safety information DANGER When working on electrical components Risk of electrocution When work is carried out on electrical components Only have work carri...

Page 5: ...rt up NOTICE You should have the initial startup carried out by the authorised heating engineer from Froling customer services 2 1 1 Connecting the bus cable For the bus connections between the individual modules cable type LIYCY paired 2x2x0 5 should be used The connection to the 5 pin plugs should be carried out according to the following diagram UBUS CAN H CAN L UBUS CAN H CAN L Braided shield ...

Page 6: ...calibrate the touchscreen you much press five points indicated by a crosshair in the order shown NOTICE Inaccurate calibration If you do not tap the indicated points accurately the control may stop working properly and a software update may be required 2 1 4 Setting the module address Once the display has been calibrated the module address must be set If it is the first RBG 3200 Touch in the bus s...

Page 7: ...will then be loaded into the RBG 3200 Touch This process can be time consuming The following screen appears after the RBG 3200 Touch s first system start The basic screen displays only the external temperature as no components have been assigned to the RBG 3200 Touch yet Installation 2 Initial start up Operating Instructions RBG 3200 Touch B0780115_en 7 ...

Page 8: ...r the room G Up arrow to increase the desired temperature setpoint for the room H Info menu icon for viewing all system information I System menu icon for opening the system settings All parameters can be displayed edited depending on the user level J Favourites menu icon for viewing the available quick functions K Mode icon for setting the mode of the allocated heating circuit 3 1 1 Status LED Th...

Page 9: ... left arrow Quick menu icon Opens the quick menu Various functions are available depending on the user level system configuration and current status Pen icon If a parameter has the pen symbol beside it it means that the parameter can be adjusted If you open the parameter either the numeric keypad or a list box for changing the value of the parameter will appear Confirm icon Confirms any values ent...

Page 10: ...the corresponding menu item The system menu is structured in a circular buffer which can be navigated using the right and left arrows The next time you open the system menu the last page viewed will be displayed 4 2 1 Navigating the menus After you open a menu item the corresponding status display with current values will appear If for example several heating circuits are installed you can use the...

Page 11: ...ill appear The parameter list shows three parameters The up and down arrows can be used to scroll through longer lists of parameters If you have reached the start or end of the parameter list the relevant arrow symbol will become inactive Operation 4 Navigation within the system menu Operating Instructions RBG 3200 Touch B0780115_en 11 ...

Page 12: ...n icon beside it Depending on the type of parameter either the numeric keypad or a list box will appear In both cases you need to tap the confirm icon to save the entry 4 Operation Adjusting parameters 12 Froling GesmbH A 4710 Grieskirchen Industriestraße 12 www froeling com ...

Page 13: ...ft or right arrow to navigate to the desired day of the week Tap the symbol under the day of the week The edit window will appear You can specify up to four time windows per component and day Tap the desired time window The time window will open for editing Set the start and end time for the time window using the up and down arrows Save the time window setting by tapping on the confirm icon Operat...

Page 14: ...minute displays are replaced by two dashes If you want to apply the time window setting to another day in addition you can do this by activating the relevant day 4 Operation Setting times 14 Froling GesmbH A 4710 Grieskirchen Industriestraße 12 www froeling com ...

Page 15: ...down arrows NOTICE The room temperature can only be changed in automatic mode when the heating circuit control is active and in party mode 4 6 Set the heating circuit mode The current mode for the allocated heating circuit is displayed in the basic display to the left of the mode icon Operation 4 Setting the room temperature setpoints Operating Instructions RBG 3200 Touch B0780115_en 15 ...

Page 16: ...3 Party mode The allocated heating circuit is set to heating mode until the end of the next heating phase or until a different mode is activated 4 6 4 Setback mode The allocated heating circuit is set to setback mode until the start of the next heating phase or until a different mode is activated The temperature setpoint displayed in setback mode on the basic screen is for display purposes only an...

Page 17: ...Room temperature 20 C Prerequisite Heating circuit used in conjunction with remote control Shows the current room temperature Override switch Auto Prerequisite Heating circuit used in conjunction with remote control Shows the current heating circuit mode Party party mode the current or next setback program is ignored Setback setback mode the heating phases are ignored Auto automatic mode heating p...

Page 18: ...at external temperature of 10 C 40 C First setting point for definition of heating curve Flow temperature SP at external temperature of 10 C 60 C Second setting point for definition of heating curve Reduction of flow temperature in setback mode 15 C The flow temperature is reduced by this value during setback mode External temperature below which the heating circuit pump switches on in heating mod...

Page 19: ...ted Frost protection temperature 10 C If the room temperature or the flow temperature is lower than the set value the heating circuit pump will be switched on and the heating circuit mixer keeps to the maximum heating circuit flow temperature that is set 5 1 3 Heating Times System menu Heating See Setting times page 13 Menu overview and parameters 5 Heating Operating Instructions RBG 3200 Touch B0...

Page 20: ...oading of the DHW tank takes place when either the time window has elapsed or the temperature value which is set under Set DHW temperature is reached DHW tank bottom temperature 55 C Prerequisite Solar panel system is regulated by Froling Current temperature in the area of the reference sensor of the solar panel system DHW tank pump control 0 Specifies the speed of the DHW tank pump as a percentag...

Page 21: ...is below 45 C If the DHW tank temperature falls below the value set here the time window is active and the loading source boiler or buffer tank indicates the set loading increase and the DHW tank loading is started 5 2 3 Water Times System menu Water See Setting times page 13 Menu overview and parameters 5 Water Operating Instructions RBG 3200 Touch B0780115_en 21 ...

Page 22: ...d In order to perform the calculation more precisely the use of a collector return feed sensor is recommended Flow through l h 0l Prerequisite External volume pulse transmitter installed Display of the water quantity currently being pumped through the solar collector Todays yield kWh 0 Display of the heat quantity that has been supplied by the solar panel system today Total yield kWh 0 Display of ...

Page 23: ...ger and buffer tank 100 Prerequisite Hydraulic System 12 or Hydraulic System 13 Display of the current speed of the pump between heat exchanger and buffer tank Pump between heat exchanger and DHW tank 0 Prerequisite Hydraulic System 12 Display of the current speed of the pump between heat exchanger and DHW tank Diverter valve for top bottom coils 100 Prerequisite Hydraulic System 12 or Hydraulic S...

Page 24: ... the reference temperature in the DHW tank or buffer tank by this value Temp difference to stop collector pump 5 C The collector pump switches off when the difference between the collector temperature and reference temper ature in the DHW tank or buffer tank is lower than this value Maximum buffer tank bottom temperature during solar charging 85 C If the sensor for the solar reference temperature ...

Page 25: ...is used In order to perform the calculation more precisely the use of a collector return feed sensor is recommended Flow through l h 0l Prerequisite External volume pulse transmitter installed Display of the water quantity currently being pumped through the solar collector Todays yield kWh 0 Display of the heat quantity that has been supplied by the solar panel system today Total yield kWh 0 Displ...

Page 26: ...ite Master boiler in the cascade or hydraulic system 4 or fuel amount calculation Shows the current temperature in the lower part of the buffer tank Buffer tank bottom temperature 40 C Shows the current temperature in the lower part of the buffer tank Buffer tank pump control 40 Display of the current speed of the buffer loading pump Buffer tank charge 65 Prerequisite Master boiler in the cascade ...

Page 27: ... all available heating circuits Buffer tank fully loaded if temperature difference between boiler and bottom buffer tank 10 C From this difference between the boiler temperature setpoint that has been set and the current temperature in the lower part of the buffer tank buffer tank loading is stopped 5 4 3 Buffer tank Times System menu Buffer tank See Setting times page 13 Menu overview and paramet...

Page 28: ... of the burner relay 0 Secondary boiler not active 1 Secondary boiler active Manual start of secondary boiler only when ID fan is switched off OFF OFF Secondary boiler is controlled according to the program that is set ON Secondary boiler is activated immediately NOTICE Burner blockage noted 5 Menu overview and parameters Boiler 2 28 Froling GesmbH A 4710 Grieskirchen Industriestraße 12 www froeli...

Page 29: ... secondary boiler reaches the specified temperature the loading pump is started and switches the isolating valve Temperature difference between secondary boiler and buffer tank 10 C Temperature difference between secondary boiler and upper temperature in layered tank to activate the load ing pump of the secondary boiler Secondary boiler delivery temperature 95 C Prerequisite Hydraulic system 3 in ...

Page 30: ...al controller e g tiled stove with water pock et Heat sink sensor 40 C Display of the current temperature of the heat sink for the differential controller e g layered tank Pump speed 0 Specifies the current speed of the differential controller pump 5 Menu overview and parameters Difference regulator 30 Froling GesmbH A 4710 Grieskirchen Industriestraße 12 www froeling com ...

Page 31: ...s flow rate Speed of the circulation pump 100 Specifies the current speed of the circulation pump 5 7 2 Circulation pump Temperatures System menu Circ pump Switch off the pump at what return temperature in the circulation line 35 C If the set temperature at the return circulation line is reached the circulation pump will be deactivated NOTICE Parameter only relevant when using a return feed sensor...

Page 32: ...nd on the boiler config uration Boiler temperature 25 C Flue gas temperature 28 C ID fan control 0 Residual oxygen content 1 9 Outside air temperature 2 C Service hours 15h Hours since last maintenance 15h Software version Version 50 04 Build 05 10 5 Menu overview and parameters System 32 Froling GesmbH A 4710 Grieskirchen Industriestraße 12 www froeling com ...

Page 33: ...via the froeling connect com online platform using a touch display the issue of a password is required NOTICE The same password can be assigned for each touch display Password for boiler display 1 Password for Touch display with address 1 1 Password for touch display with address 7 1 Menu overview and parameters 5 System Operating Instructions RBG 3200 Touch B0780115_en 33 ...

Page 34: ... the room for adjusting the backlight Maximum backlight 80 The brighter it is in the room the more the background of the touch display is illuminated This is where you can limit the maximum backlight Minimum backlight 20 The darker it is in the room the less the background of the touch display is illuminated This is where you can set the minimum backlight Delay for screensaver 0 disables the scree...

Page 35: ...NS server can be manually set IP address 127 0 0 0 Subnet mask 255 255 0 0 Default gateway 0 0 0 0 DNS server 0 0 0 0 5 10 2 Display settings Date Time System menu Display settings Date Time Date 08 01 2015 Display and setting of current date Time 14 40 15 Display and setting the current time Menu overview and parameters 5 Display settings Operating Instructions RBG 3200 Touch B0780115_en 35 ...

Page 36: ...op The status LED flashes red the boiler switches off immediately and the heating circuit controller and pumps remain active A window with the corresponding fault text will also appear Pressing the Cancel icon takes you back to the basic display If the quick select icon and the warning triangle flash alternately there is still a fault The Error display button will now appear in the quick menu 6 1 ...

Page 37: ...problem If there are several options available these will be listed one below the other Once the fault has been resolved tap the Cancel icon to return to the basic display Troubleshooting 6 Procedure for fault messages Operating Instructions RBG 3200 Touch B0780115_en 37 ...

Page 38: ...inux bin rootfs img update into the USB port Display settings menu Software update Service Set Restart control Update parameter to Yes Update will begin Display during the update 7 FAQ Updating the software of the touch control 38 Froling GesmbH A 4710 Grieskirchen Industriestraße 12 www froeling com ...

Page 39: ...ng the display will start calibrating Once the calibration is complete it will restart again to finish The touch control software is now up to date NOTICE Inaccurate calibration If you do not tap the indicated points accurately the control may stop working properly and a software update may be required FAQ 7 Updating the software of the touch control Operating Instructions RBG 3200 Touch B0780115_...

Page 40: ... Display settings menu Scroll down with the down arrow until the Software update Service submenu appears and open the submenu In the Software update Service menu open the Recalibrate touch control parameter 7 FAQ Calibrating the touchscreen 40 Froling GesmbH A 4710 Grieskirchen Industriestraße 12 www froeling com ...

Page 41: ... press five points indicated by a crosshair in the order shown The control will restart after calibration NOTICE Inaccurate calibration If you do not tap the indicated points accurately the control may stop working properly and a software update may be required FAQ 7 Calibrating the touchscreen Operating Instructions RBG 3200 Touch B0780115_en 41 ...

Reviews: