5.1.2 Heating - Temperatures
System menu
Heating
Desired room temperature during heating mode
20°C
Prerequisite: Heating circuit used in conjunction with remote control
Room temperature which is regulated during the set heating times
Desired room temperature during setback mode
16°C
Prerequisite: Heating circuit used in conjunction with remote control
Room temperature which is regulated outside of the set heating times
Flow temperature SP at external temperature of +10°C
40°C
First setting point for definition of heating curve
Flow temperature SP at external temperature of -10°C
60°C
Second setting point for definition of heating curve
Reduction of flow temperature in setback mode
15°C
The flow temperature is reduced by this value during setback mode.
External temperature below which the heating circuit pump switches on in heating mode
18°C
If the external temperature exceeds this value during heating, the heating circuit pumps and mixing valve are
deactivated.