3.6 Use with storage tank
NOTICE
In principle it is not necessary to use a storage tank for the system to run
smoothly. However, we recommend that you use the system with a storage tank,
as this ensures a continuous supply of fuel in the ideal output range of the boiler.
For the correct dimensions of the storage tank and the line insulation (in accordance
with ÖNORM M 7510 or guideline UZ37) please consult your installer or Froling.
3.7 Chimney connection/chimney system
EN 303-5 specifies that the entire flue gas system must be designed to prevent,
wherever possible, damage caused by seepage, insufficient feed pressure and
condensation. Please note in this respect that flue gas temperatures lower than 160K
above room temperature can occur in the permitted operating range of the boiler.
NOTICE! Please see the technical data contained in the assembly instructions for
further information about standards and regulations as well as the flue gas
temperatures when clean and the other flue gas values!
Notes for operating a heating system
3
Use with storage tank
Operating Instructions T4e | B1560520_en
23