OPERATION 
LCD Control 

Please take note LCD Display and control is inoperable when the unit is connected to DMX. 
LCD display has 4 buttons., see below: 

 

MENU: Enters/changes setting mode  
UP/TIMER: Increase value; Timer mode 

  

DOWN/VOLUME: Decrease value; haze output 
ENTER/STOP: Enter or exit setting mode; STOP 
 

Press ENTER button, there are ten pages in total, as following: 

1.“READY to Haze” Machine finishes heating.  
2.Interval Set: 5

200s 

3.Duration Set: 5

200s 

4.Timer out: 1%

100% haze output under “TIMER” mode  

5.Volume out:  1%

100% haze output under Volume mode (Rotary Knob Function) 

6.Fan speed: 1%

100% (Rotary Knob Function) 

7. Fluid Sensor: ON or OFF 
8. DMX 512 ADD: 1

512 

9.Direct timer: Direct timer on/off after power on 
 
Under any setting pages, press “STOP” to exit or return to the page one. 
When the unit is working, press “STOP” to stop running and return to the page one.  
After enter into different setting pages, press “UP” and “DOWN” to change the value.  
When it is in the page one, press “TIMER” button to enter into timer mode.  
 

DMX Control 

When the unit is connected to DMX, LCD display will show the address value. In such case, press “UP” and 
“DOWN” button to change the address.  
There are two DMX channels. 
Channel 1: Fan output. 0~5 OFF; 6~255 increase  
Channel 2: Haze output. 0~5 OFF; 6~255 increase  
 