OPERATION
LCD Control
Please take note LCD Display and control is inoperable when the unit is connected to DMX.
LCD display has 4 buttons., see below:
MENU: Enters/changes setting mode
UP/TIMER: Increase value; Timer mode
DOWN/VOLUME: Decrease value; haze output
ENTER/STOP: Enter or exit setting mode; STOP
Press ENTER button, there are ten pages in total, as following:
1.“READY to Haze” Machine finishes heating.
2.Interval Set: 5
~
200s
3.Duration Set: 5
~
200s
4.Timer out: 1%
~
100% haze output under “TIMER” mode
5.Volume out: 1%
~
100% haze output under Volume mode (Rotary Knob Function)
6.Fan speed: 1%
~
100% (Rotary Knob Function)
7. Fluid Sensor: ON or OFF
8. DMX 512 ADD: 1
~
512
9.Direct timer: Direct timer on/off after power on
Under any setting pages, press “STOP” to exit or return to the page one.
When the unit is working, press “STOP” to stop running and return to the page one.
After enter into different setting pages, press “UP” and “DOWN” to change the value.
When it is in the page one, press “TIMER” button to enter into timer mode.
DMX Control
When the unit is connected to DMX, LCD display will show the address value. In such case, press “UP” and
“DOWN” button to change the address.
There are two DMX channels.
Channel 1: Fan output. 0~5 OFF; 6~255 increase
Channel 2: Haze output. 0~5 OFF; 6~255 increase