2
OPERATION
Plug the power cord into a grounded electrical outlet and switch the main power on.
Starting Operation
o
After switching on via the On/Off switch the controllers LCD screen will display “WARMING UP”. When
the unit has reached the correct temperature, the LCD display will show “READY” and the unit is now
ready for operation
Manual Output
o
For manual output, simply press the “MANUAL” button and hold until the desired amount of output is
emitted.
Constant Burst Operation
o
To set unit for constant output, press the “LOCK” button. To stop the output, simply press the “LOCK”
button again. During this operation, you can change the volume output by pressing the “UP” and
“DOWN” buttons.
Timer Mode
o
Press the timer button to start timer functionality according to the LCD display settings.
DMX Control Mode
o
Operating in a DMX control mode gives the user the greatest flexibility when it comes to customizing or
creating a show. When DMX is plugged in, the LCD screen will show the DMX Address Menu and allow
adjustment of the address. When the unit is low on fluid, the LCD screen will show the Reset Fluid Sensor
Menu and after resetting the fluid sensor back to the DMX Address Menu. When DMX cables are
unplugged, the LCD screen will show the home menu.
MAINTENANCE
Cleaning your fog bubble machine regularly will help reduce costly parts replacement and repair charges.
Please follow these instructions for safely cleaning after 40 hours of operation or before storing the fog bubble
machine, to ensure long lifespan. Tools: Clean lint free cloth, coffee filter or similar fine mesh filter cloth, plastic
or glass container larger than the reservoir size (do not use metal), distilled water and Froggys Fog fluid.
1.
Allow the machine to cool down before handling.
2.
Drain any fog solution that remains in the tank into a container through the filter mesh for reuse.
3.
Dispose of any bubble solutions and wipe tray/wands
4.
Add distilled water to fill the fog fluid reservoir approximately 1/3.
5.
Run machine for 10 minutes. Fog will come out the first few cycles, followed by distilled water vapor.
6.
Turn off the machine and allow to cool down, then drain the distilled water from the reservoir.
7.
Refill the reservoir approximately 1/3 with good quality fog solution.
8.
Turn fog machine on, run for 10‐15 minutes. Water vapor steam will come out the first few cycles,
followed by fog. Continue steaming the machine for 5‐10 cycles.
9.
Turn off the machine and allow to cool, then wipe machine clean with clean lint free cloth.
10.
Leave the fog solution in the reservoir. The fog solution acts a lubricant and conditioner for the plastic and
rubber parts in the fluid pump.
11.
Store the fog machine in a cool, dry place when not in use. Avoid freezing temperatures, high heat
above 120 degrees and humid/damp locations which may cause control board failure.
12.
If possible, remove from storage after 6 months and operate the fog machine for 15 minutes or more,
then repeat step 8 – 10.