- 6 -
There are two DMX control channels, as follows:
Channel 1: Control the fan speed, DMX value 0-5 No Function (OFF), 6-255 Fan speed 1-100%.
Channel 2: Control the snow output, DMX value 0-5 No Function (OFF), 6-255 snow output 1-100%.
Notes: Under DMX control, if channel 1 is “OFF” while channel 2 is “ON”, then the fan speed would be the minimum speed.
3.3
W
IRELESS REMOTE
F
UNCTION
Wireless remote control can work over 164 feet. This function is available once the machine is connected, powered on and the DMX
control is shut off. Remote controller has two buttons, the left one for starting snowflake output, the right one for stopping
snowflake output. The same machine can be matched with up to five controllers with different frequency channels. By doing so,
each machine can be controlled independently without effects from other remote controllers. Instruction as follows:
3.3.1
The pairing of the wireless remote
After the machine is powered on when the wireless remote function is on (Page “Wireless Set” shows “ON”), the LCD displays
“Wireless Setup” (wireless remote paring) page, then the remote control can be paired. Press any button of wireless remote (last for
1s at least), the display page will flash twice showing the paring of remote controller is done successfully. The same machine can be
paired with five controllers with different frequency channels at most. If user pair the sixth one, then the memory for the first one
will be erased.
If the machine has been paired with five controllers during the last use, and user pair it with another new remote in next time’s use,
it would only recognize the new remote rather than the previous five.
For example:
If one machine matches three remote controllers. During 15s after the machine is powered on, the LCD display shows “Wireless
Set”, press any buttons on the three remotes respectively within 15s. The display page will flash twice showing the match of
remote controller being matched successfully, or it needs to rematch.
If one wireless remote controls two or more machines. Power on two machines simultaneously, LCD display screens will show
“Wireless Set”, press any button on the remote till the display pages flash twice.
3.3.2
Operation under remote control
Press ON button to run the unit or OFF button to stop it. Under remote control, the snowflake volume output is based on the value
of “Manual Volume Snow Out” setting. For example, if the volume setting is 1% set under “Manual Volume Snow Out” page, then it
will be 1% when controlled by wireless remote. If it is 100 % volume output under “Manual Volume Snow Out” page, it will be 100%
accordingly under remote control
Note:
When paring the wireless remote, keep pressing the “ON” button till the display page flashes twice. By doing this, remotes are
matched successfully.
If the wireless remote is under OFF status, when the machine is powered on again. The LCD display will not show “wireless set” or
Paring page.
Wireless remote-control function is unavailable under DMX control.
3.4
F
LUID
S
ENSOR
This machine use fluid-test PCB to detect whether there is fluid going through or not, hence to protect the pump from being
damaged when there is no fluid.
3.4.1
How to activate “no-fluid protection”
When this function is set to “ON” and the internal detector check out there is no fluid inside the tube for over 10s, no-fluid
protection activates. The LCD display shows
“
NO Fluid” and keeps flashing. The machine stops working.