Froggy's Fog BOREAS C6 User Manual Download Page 7

- 6 - 

 

There are two DMX control channels, as follows: 

ž

 

Channel 1: Control the fan speed, DMX value 0-5 No Function (OFF), 6-255 Fan speed 1-100%. 

ž

 

Channel 2: Control the snow output, DMX value 0-5 No Function (OFF), 6-255 snow output 1-100%. 

Notes: Under DMX control, if channel 1 is “OFF” while channel 2 is “ON”, then the fan speed would be the minimum speed. 

3.3

 

W

IRELESS REMOTE 

F

UNCTION

 

Wireless remote control can work over 164 feet. This function is available once the machine is connected, powered on and the DMX 
control is shut off. Remote controller has two buttons, the left one for starting snowflake output, the right one for stopping 
snowflake output. The same machine can be matched with up to five controllers with different frequency channels. By doing so, 
each machine can be controlled independently without effects from other remote controllers. Instruction as follows: 

3.3.1

 

The pairing of the wireless remote 

After the machine is powered on when the wireless remote function is on (Page “Wireless Set” shows “ON”), the LCD displays 
“Wireless Setup” (wireless remote paring) page, then the remote control can be paired. Press any button of wireless remote (last for 
1s at least), the display page will flash twice showing the paring of remote controller is done successfully. The same machine can be 
paired with five controllers with different frequency channels at most. If user pair the sixth one, then the memory for the first one 
will be erased. 

If the machine has been paired with five controllers during the last use, and user pair it with another new remote in next time’s use, 
it would only recognize the new remote rather than the previous five.  

For example: 

ž

 

If one machine matches three remote controllers. During 15s after the machine is powered on, the LCD display shows “Wireless 
Set”, press any buttons on the three remotes respectively within 15s. The display page will flash twice showing the match of 
remote controller being matched successfully, or it needs to rematch. 

ž

 

If one wireless remote controls two or more machines. Power on two machines simultaneously, LCD display screens will show 
“Wireless Set”, press any button on the remote till the display pages flash twice.  

3.3.2

 

Operation under remote control  

Press ON button to run the unit or OFF button to stop it. Under remote control, the snowflake volume output is based on the value 
of “Manual Volume Snow Out” setting. For example, if the volume setting is 1% set under “Manual Volume Snow Out” page, then it 
will be 1% when controlled by wireless remote. If it is 100 % volume output under “Manual Volume Snow Out” page, it will be 100% 
accordingly under remote control 

Note: 

ž

 

When paring the wireless remote, keep pressing the “ON” button till the display page flashes twice. By doing this, remotes are 
matched successfully. 

ž

 

If the wireless remote is under OFF status, when the machine is powered on again. The LCD display will not show “wireless set” or 
Paring page. 

ž

 

Wireless remote-control function is unavailable under DMX control. 

3.4

 

F

LUID 

S

ENSOR

 

This machine use fluid-test PCB to detect whether there is fluid going through or not, hence to protect the pump from being 
damaged when there is no fluid.  

3.4.1

 

How to activate “no-fluid protection” 

When this function is set to “ON” and the internal detector check out there is no fluid inside the tube for over 10s, no-fluid 
protection activates. The LCD display shows

 “

NO Fluid” and keeps flashing. The machine stops working.

 

Summary of Contents for BOREAS C6

Page 1: ...USER MANUAL...

Page 2: ...k Start Guide 3 2 3 BOREAS C6 CUBE Storage 3 2 4 Product Overview 4 2 5 Specifications 4 3 Operation 5 3 1 LCD Control Panel 5 3 2 DMX Control 5 3 3 Wireless remote Function 6 3 3 1 The pairing of the...

Page 3: ...ication otherwise it might cause damage to the unit or danger of fire Doing so will void any warranty For adult use only Machine must be installed out of the reach of children Never leave the unit run...

Page 4: ...Turn the Power Switch On Wait for Wireless setup to complete LCD read out will say Ready to Make Snow On remote push the on button to start If no fluid is flowing through the machine the pump may nee...

Page 5: ...Power Switch Power Socket Fluid Inlet Junction 5 pin DMX Socket 5L Fluid Container Rubber Feet 2 5 SPECIFICATIONS Voltage AC 120V Rate 50 60Hz Power 550W Current limited device 8A 250V Tank capacity 5...

Page 6: ...om 1 to 100 DMX512 Address Setting of DMX channel Fluid Sensor Setting of no fluid protection press ENTER button to save after choosing ON OFF setting Wireless Set Setting of the wireless remote contr...

Page 7: ...te rather than the previous five For example If one machine matches three remote controllers During 15s after the machine is powered on the LCD display shows Wireless Set press any buttons on the thre...

Page 8: ...output OFF then push the slider up to value above 5 Snow output ON In this case the pump also works at the maximum output until the tube is filled with fluid and the unit exits no fluid protection mod...

Reviews: