/ / FKL PUMP SERIES / / /
12
Fig. 12
Air pocket in pipe
Fig. 13
Dip in pipe
►
Run pipe connections in accordance with:
pressure, temperature and type of pumping medium.
►
Lay and connect the pipes to ensure that no stresses are ap-
plied to the pump.
►
Secure pipes to ceilings, walls, or floor using pipe clamps.
►
Align pipes flush with pump connections using a bracket.
6.6
Electrical Connection
WARNING
Electrostatic Charge Buildup
Electric shock.
►
Ground pipes and pump to dissipate electric charge.
Electrical connection may only be performed by a qualified elec-
trician.
Procedure
1. Heed the connection values on the motor's rating plate. En-
sure that the specified current and voltage values are not ex-
ceeded.
2. Only connect the motor to fuse-protected circuits to prevent
excessive current consumption.
3. Connect the motor according to the circuit diagram in the
terminal box of the motor.
4. Turn on the motor for 2 to 3 seconds. Check the direction of
rotation of the pump and the motor fan wheel, see
"Direction of rotation left," page 12
. Ensure that the pump is filled with me-
dium to prevent dry running of the shaft seal.
Fig. 14
Direction of rotation left
Fig. 15
Direction of rotation right
5. Reverse the polarity if the direction of rotation is incorrect.
6.7
Connection of Sealing or Quenching Liquid
(Optional)
For versions with double shaft seals, the shaft seal chamber
must be flushed with sealing or quenching liquid.
►
Use a suitable medium as a sealing or quenching liquid.
►
Depending on pump size, approx. 10-30 liters per hour at 0.1
to 0.2 bar.
6.7.1
Installation of Pipes
1. Install and seal the supplied flushing tubes.
2a. Provide water connections:
►
Install the inlet line on the
bottom
of the shaft seal.
►
Install the drain line on the
top
of the shaft seal.
2b. Provide vapor connections:
►
Install the inlet line on the
top
of the shaft seal.
►
Install the drain line on the
bottom
of the shaft seal.
3. Install the following fittings in the pipes:
– Throttle valve in inlet line
– Flowmeter (pressure gauge) in drain line
Pressure
side
Inlet
Suction side
Outlet
Pressure side
Outlet
Suction side
Inlet