12
3.1.3.2 Temperature limits of pump type FC
Depending on the design, different maximum pumping media temperatures are
permissible for pumps of the FC series.
If the pumping media temperatures are not specified in the documentation, the
lower value is permissible.
Temperature class;
Temperature limit
value
Max. permissible
surface temperature [°C]
Max. permissible
pumping media
temperature [°C]
T1
450
≤ 90/110
T2
300
≤ 90/110
T3
200
≤ 90/110
T4
135
≤ 80/80
Table 2: Max. permissible pumping media temperatures in [°C] for pump type FC
3.1.3.3 Temperature limits of pump type FPC
Depending on the design, different maximum pumping media temperatures are
permissible for pumps of the FC series.
If the pumping media temperatures are not specified in the documentation, the
lower value is permissible.
Temperature class;
Temperature limit
value
Max. permissible
surface temperature [°C]
Max. permissible
pumping media
temperature [°C]
T1
450
≤ 150
T2
300
≤ 150
T3
200
≤ 150
T4
135
≤ 100
Table 3: Max. permissible pumping media temperature in [°C] for FPC
Temperature limit of pump type FPC (Ex-Inside) Zones 1 & 2
FPC pumps in which an occasional occurrence of explosive gas
atmospheres within the pump is permissible (category 2; IIB; EPL Gb /
Gc; additional marking on rating plate X), the following must be
observed:
- Explosive atmospheres within the pump with the temperature
class assignment T4, T5 and T6 are not permitted.
- The max. permissible pumping media temperature for the EPL
Gb / Gc; T1-T3 is T
Pumping medium
≤ 100 °C.