background image

Key

1. 

Armset Pivot Screw

2. Armset

3. Nut

4. 

Adjustment Valves

5. 

Threaded Arm (Bolt)

6. 

Parallel Bracket

7. 

Door Closer Body

8. 

Dust Cap

9. 

Washer Screw

10. 

Assembling Screw

1

2

3

4

5

6

7

8

9

10

45˚ Preload

73 Series Door Closer Installation

Parallel Arm Installation (Push Side) - Fig 66

Door Closer Body

Adjustment Valves

2 - Latching Speed

1 - Closing Speed

Parallel

Arm Bracket

To Increase Closing Speed:

Adjust screw valve (1) anti-clockwise by quarter turns until desired speed has been achieved

To Reduce Closing Speed:

Adjust screw valve (1) clockwise by quarter turns until desired speed has been achieved

To Increase Latching Speed:

Adjust screw valve (2) anti-clockwise by quarter turns until desired speed has been achieved

To Reduce Latching Speed:

Adjust screw valve (2) clockwise by quarter turns until desired speed has been achieved

CAUTION

Adjusting valves more than 2 full turns anti-clockwise from 

factory settings will result in oil leakage damaging the door closer.

acceleration

deceleration

Hinge knuckle

is 

not

 visable

Door Frame

Door

Unit 14 Pindar Road, Hoddesdon, Hertfordshire, EN11 0DE

Tel: +44 (0)1992 443 010 | Fax: +44 (0)1992 443 020

EN1154:1997 + A1:2002 

*Fig 1 application only

EN1634-1:2000 FD60 timber FD240 steel

CE 1121-CPD-AD1069 (2007)

Certifire CF600

3 8 3 1 1 3

Step by Step Installation Guide

Use the appropriate template for your installation and place

the template on the door and frame. Pilot drill all fixing holes

as per the template.

1. 

Position the door closer with the adjustment valves facing

 

away from the hinge side of the door. Secure the door closer

 

and bracket using the screws provided into the pre-drilled 

 

pilot positioning holes.

2. 

Remove the shoe from the door closer arm.

3. 

Attach the armset to the pivot on the door closer body parallel

 

to the door/frame and secure using the washer screw.

4. 

Tension the door closer arm and adjust the arm length

 

accordingly. Secure the arm to the figure 66 bracket and tighten

 

the arm set nut.

5. 

Add the dust cap to the unused pivot.

6. 

Adjust the closing and latching speeds as required -

 

refer to adjustment instructions.

 

NB after the first month of operation the closing and latching

 

speed valves may require minor adjustment.