FAULT
POSSIBLE REASONS
HANDLING
not cool enough.
The products
are warm.
The ICM has recently been reloaded with
warm products. It takes 8-16 hours to
cool them down.
Preferably, reload the ICM before night
closing.
The ICM is loaded in such a way that the
air circulation in the interior is getting
blocked.
Load the ICM according to the
standards you have been provided
with by the company.
The door does not seal properly.
Repair the doors for proper closing
(this type of repair should be
performed by an authorized
technician).
Leakage in the cooling system.
Repair the leakage (this type of repair
should be performed by an authorized
technician).
The ICM
sometimes
makes noise.
For this particular ice cold
merchandiser, a powerful mechanism is
needed and consequently a certain
amount of noise cannot be avoided.
Ice Cold Merchandisers are of
dynamic type, according to the
specifications that the company is
offering.
Intense metallic noise.
Call a service technician.
Inclined or curved floor.
Level the ICM properly by adjusting its
feet. Placing a spirit level on the top of
the ICM will assist you in leveling it.
There is water
on the floor.
The drainage hole for the condensate
water is blocked.
Unblock the drainage hole.
There is a leakage in the tray.
Call a service technician.
The lights don’t
work.
The fluorescent tubes or ballast or starter
are out of order.
Call a service technician.
If after all the above-mentioned checks the problem with your ICM remains, contact the customer
service department of your supplier and provide the following information:
•
Type of ICM
•
Serial number of the ICM
•
Brief description of the problem / observation
11. First aid
In case of accident, it is recommended:
ACCIDENT
IMMEDIATE ACTION
Inhalation of refrigerant
Take deep breaths of clean air. If irritation persists, contact a
doctor.
Contact with eyes
Wash your eyes thoroughly with plenty of water for at least 15 minutes
and then consult a doctor.
Contact with skin
Wash immediately with water.