30" Electric Slide-In Range
Professional
Slide-In Range
FPES3085K F
30" Electric
Countertop Preparation
For detailed preparation instructions, refer to installation guide
on the web.
•
Flat square-finish (flat) countertop requires no preparation since
rangetop flange lays directly on countertop edge.
•
Formed front-edged countertops require front molded edge to
be shaved flat 3/4" from each front corner of opening.
•
Tile countertops may need cut back 3/4" from each front corner
of opening and /or rounded edge flattened.
•
For existing cutout width greater than 30-1/16" reduce the 3/4"
overlap dimension or for cutout width of 29", replace actual side
trim panels with smaller side trim panels, available with optional
Side Trim Kit
(refer to detailed kit installation instructions).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
Rear Filler Kit: Black – (PN # 901193-9010).
•
Side Panel Kit: Black – (PN # 903074-9010).
•
Backguard Kit: Black – (PN # 903046-9010).
•
Side Trim Kit: Black – (PN # 903075-9010).
Slide-In Range Specifications
•
Product Shipping Weight (approx.) – 240 Lbs.
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt,
60 Hertz, fused on both sides of line with ground.
(If local code
permits, range may be connected by hard-wiring or by means
of power supply cord kit.)
•
Connected Load (kW Rating) @ 240 / 208 Volts = 15.5 / 11.6 kW
•
Amps @ 240 / 208 Volts = 64.6 / 55.8 Amps
•
Recommended Circuit Breaker – 50 Amps (40 Amps minimum)
•
Always consult local and national electric codes.
•
Make sure wall coverings around range can withstand heat generated
by range.
•
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
•
Countertop MUST be level in all directions and adjustable range
height at least 1/16" greater than tallest cabinet height, to ensure
metal rangetop flange will fit properly on countertop edge.
•
When installing optional Backguard Kit, cutout depth of 21-3/4"
minimum / 22-1/8" maximum needs increased to 24".
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
•
Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than
1/4" flame-retardant millboard covered with not less than No. 28 MGS
sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
Allow 30" minimum clearance when cabinet is unprotected.
•
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
FPES3085K 02/11
© 2011 Electrolux Home Products, Inc.
Printed in the U.S.A.
Specifications
subject to change.
Accessories information available
on the web at
frigidaire.com