background image

9

INSTALLATION

1. GAS CONNECTION 

(Gas dryers only)

a. Remove the shipping cap from gas pipe at the rear of

the dryer.

NOTE: DO NOT

 connect the dryer to L.P. gas service without

converting the gas valve. An L.P. conversion kit  must
be installed by a qualified gas technician.

b. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved

pipe from gas supply line to the 3/8 inch (0.96 cm) pipe
located on the back of the dryer. Use a 1/2 inch to 3/8
inch (1.27 cm to 0.96 cm) reducer for a connection.
Apply an approved thread sealer that is resistant to the
corrosive action of liquefied gases on all pipe connections.

c. Open the shutoff valve in the gas supply line.

d. Test all connections by brushing on a soapy water solution.

NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME.

2. Connect the exhaust duct to outside exhaust system. Use

duct tape to seal all joints.

3. With the dryer in its final position, adjust one or more of the

legs until the dryer is resting solid on all four legs. Place a
level on top of the dryer.

 THE DRYER MUST BE LEVEL

AND RESTING SOLID ON ALL FOUR LEGS.

4. Plug the power cord into a grounded outlet. NOTE: Check

to ensure the power is off at circuit breaker/fuse box before
plugging the power cord into the outlet.

5. Turn on the power at the circuit breaker/fuse box.

 Before operating the dryer, make sure the dryer

area is clear and free from combustible materials, gasoline,
and other flammable vapors. Also see that nothing (such as
boxes, clothing, etc.) obstructs the flow of combustion and
ventilation air.

6. Run the dryer through a cycle check for proper operation.

NOTE:

 On gas dryers, before the burner will light, it is

necessary for the gas line to be bled of air. If the burner
does not light within 45 seconds the first time the dryer is
turned on, the safety switch will shut the burner off. If this
happens, turn the timer to "OFF" and wait 5 minutes before
making another attempt to light.

7. If your dryer does not operate, please review the "Avoid

Service Checklist" located in your Owner's Guide before
calling for service.

8. Place these instructions in a location near the dryer for future

reference.

NOTE:

A wiring diagram is located inside the dryer console or
under the top panel.

REPLACEMENT PARTS

If replacement parts are needed for your dryer, contact the
source where you purchased your dryer.

 Label all wires prior to disconnection when

servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.

 Destroy the carton and plastic bags after the

dryer is unpacked. Children might use them for play. Cartons
covered with rugs, bedspreads, or plastic sheets can become
airtight chambers causing suffocation. Place all materials in a
garbage container or make materials inaccessible to children.

 The instructions in this manual and all other

literature included with this dryer are not meant to cover every
possible condition and situation that may occur. Good safe
practice and caution 

MUST

 be applied when installing, operating

and maintaining any appliance.

Summary of Contents for P/N 134296400A (0404)

Page 1: ...of Your Dryer 4 Mobile Home Installation 5 Rough In Dimensions 5 6 Unpacking 6 Reversing Door Swing 6 Electrical Installation 7 Grounding Requirements 7 Electrical Connections 3 wire 8 Electrical Connections 4 wire 8 Installation 9 Replacement Parts 9 Printed in U S A P N 134296400A 0404 Installation Instructions Gas Electric Dryer Before beginning installation carefully read these instructions Th...

Page 2: ...contact with exhaust system The dryer MUST NOT be exhausted into a chimney a wall a ceiling or any concealed space of a building which can accumulate lint resulting in a fire hazard Exceeding the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulation of lint in the exhaust system Plugging the system could create a fire hazard as well as increase dryi...

Page 3: ...temperature to air fluff cool down and start the dryer 3 Read the measurement on the manometer 4 The system back pressure MUST NOT be higher than 0 75 inches of water column If the system back pressure is less than 0 75 inches of water column the system is acceptable If the manometer reading is higher than 0 75 inches of water column the system is too restrictive and the installation is unacceptab...

Page 4: ... centimeters 3 inches 7 6 cm from bottom and top of door THIS DRYER MUST BE EXHAUSTED OUTDOORS 5 The following illustrations show minimum clearance dimensions for proper operation in a recess or closet installation 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INST UNDER COUNTER INSTALLA ALLA ALLA ALLA A...

Page 5: ...OPTIONAL OPTIONAL OPTIONAL OPTIONAL OPTIONAL VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT VENT KNOCKOUT 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm MOBILE HOME INSTALLATION 1 Dryer MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter with no obstruction...

Page 6: ...counter model clothes dryers the top panel may be removed for installation 2 Return the dryer to an upright position PACKING FOAM SHIPPING REMOVE 4 SCREWS ONE FROM EACH HINGEFIRST ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS ROUGH IN DIMENSIONS TOP CONSOLE MODELS 68 6 cm 68 6 cm 68 6 cm 68 6 cm 68 6 cm SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW SIDE VIEW OPTIONAL OP...

Page 7: ...plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances If in doubt call a licensed electrician ALL GAS Dryers This dryer is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong fr...

Page 8: ...UTRAL GROUND WIRE ELECTRICAL CONNECTIONS FOR 3 WIRE SYSTEM Non Canadian ELECTRIC Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp p...

Page 9: ...so see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happen...