CHECK FILTER FEATURE, YOU WILL SEE:

2009 Electrolux Home Products, Inc.

All rights reserved.

DO THIS:

PRESS FILTER 

RESET BUTTON

TIMER: DELAY STOP / START FEATURE

YOU WILL SEE HOW MUCH TIME IS CHOSEN:

FIRST

DO THIS:

PRESS

TIMER BUTTON

THEN

DO THIS:

PRESS

UP/DOWN BUTTONS

Note: This feature is a reminder to clean the Air Filter (See 
Care and Cleaning) for more efficient operation. The LED 
(light) will illuminate after 250 hours of operation. To reset 
after cleaning the filter, press the "Filter Reset" button and 
the light will go off.

If the display reads "AS" , a sensor has failed. Contact your 
Authorized Frigidaire Service Center.

FAULT CODES:

Note: For Delay Stop, the unit must be in the On position

Note: For Delay Start, the unit must be in the Off position.
First, Press TIMER button, then adjust timer setting, tap or hold the UP arrow (     ) or the DOWN arrow (     ) to change delay 
timer at 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time 
remaining until start (8, 7.5, 7, etc.). The Delay Start Operation automatically selects cooling with maximum Fan speed (if Cool, 
Energy Saver, or Fan Only was the last mode selected) . The temperature maintained will be the same as previously set. To change 
the set temperature, press "COOL" then Up or Down arrows until the desired temperature is indicated on the display. After 5 
seconds, the control will automatically change the display back to the hours remaining until the unit will start/stop. Pressing the 
unit On/Off button at any time will cancel the Delay Start/Stop function. The Delay Start/Stop Feature will work until the unit either 
starts or stops. Once that happens the above steps have to be repeated again. 

Summary of Contents for LRA074AT7

Page 1: ...about the Use Care Care and Cleaning 10 Energy Saving Ideas 10 2020211A1825 June 2009 Product Registration 4 Packaging 4 Normal Sounds 4 Air Conditioner Features 5 Important Safety Instructions 2 3 Operating Instructions 5 10 of your Room Air Conditioner Before You Call 11 Major Appliance Warranty 12 ...

Page 2: ...o use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric sho...

Page 3: ...nic equipment is one yard away from the unit Do not use or store flammable gases near the unit CAUTION Avoid Injury or damage to the unit or other property The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following Plug in the Air Conditioner The power supply cord will have TWO buttons on the plug head Press the TEST button ...

Page 4: ...nd make noise because of poor wall or window construction or incorrect installation Vibration Pinging or Swishing Droplets of water hitting condenser during normal operation may cause pinging or swishing sounds Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing thro...

Page 5: ...tab and pull to remove battery tray Place battery in tray with POSITIVE side facing UP according to diagram Re insert battery tray Battery Size CR2025 TO REPLACE BATTERY TAB REMOTE CONTROL Operating Instructions NOTE The following instructions represent the Touch Pad the same instructions can be used for the Remote Control TO TURN UNIT ON YOU WILL SEE PRESS ON OFF BUTTON DO THIS Air Conditioner Fe...

Page 6: ...rns to the original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually 2009 Electrolux Home Products Inc All rights reserved YOU WILL SEE TO USE AUTO FAN FEATURE PRESS FAN BUTTON CHOOSE AUTO DO THIS YOU WILL SEE DO THIS PRESS TO SELECT Operating Instructions continued PRESS TO RAISE PRESS TO LOWER DO THIS Note Tap or hold either up or down button unti...

Page 7: ...p mode program can be cancelled at any time during operation by again pressing the Sleep button SLEEP FEATURE DO THIS PRESS SLEEP BUTTON YOU WILL SEE Note Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but keep it closed during cooling for maximum cooling efficiency You can ch...

Page 8: ... must be in the Off position First Press TIMER button then adjust timer setting tap or hold the UP arrow or the DOWN arrow to change delay timer at 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start Operation automatically selects cooling with maximum Fan speed if Cool Energy Saver or Fa...

Page 9: ... Fahrenheit between 60F and 90F degrees There is a 2 Second delay for the compressor shutting down when selecting FAN ONLY This is to cover the possibility of having to roll through to select another mode After a power outage the unit will memorize the last setting and return the unit to the same setting once power is restored Fresh Air Vent Control on some models The Fresh Air Vent allows the air...

Page 10: ...the front panel Air Directional Louvers Air directional louvers control air flow direction Your air conditioner has the louver type described below Auger Type The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed Rotate the Auger Wheels until the desired Left Right direction is obtained Pivot horizontal louvers until the desired Up Down direct...

Page 11: ...front Outdoor temperature below 60 F 16 C To defrost the coil set FAN ONLY mode O O Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Temperature is set too low for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a higher setting 11 Room temperature below 60 F 16 C Cooling may not occur until room temperature...

Page 12: ...nies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN CLAIMS BASED ON IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITE...

Reviews: