PRE-INSTALLATION REQUIREMENTS

Tools Required for Installation:

1.

3/8 in. socket with ratchet.

2.

Channel-lock adjustable pliers.

3.

Carpenter’s level.

ELECTRICAL REQUIREMENTS

CIRCUIT

 - Individual, properly polarized and grounded 15 amp.

branch circuit fused with 15 amp. time delay fuse or circuit breaker.

POWER SUPPLY

 - 2 wire, with ground, 120 volt, single phase, 60

Hz, Alternating Current.

OUTLET RECEPTACLE

 - Properly grounded 3-prong receptacle to

be located so the power supply cord is accessible when the washer is
in an installed position.

GROUNDING REQUIREMENTS

   

Improper connection of the equipment grounding

conductor can result in a risk of electrical shock. Check with a licensed
electrician if you are in doubt as to whether the appliance is properly
grounded.
1.

The washer 

MUST

 be grounded. In the event of a malfunction

or breakdown, grounding will reduce the risk of electrical shock
by a path of least resistance for electrical current.

2.

Since your washer is equipped with a power supply cord having

DRAIN REQUIREMENTS

1.

Drain capable of eliminating 17 gallons (64.3 L) per minute.

2.

A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.

3.

The standpipe height above the floor should be:

Minimum  height:

33 in. (61 cm)

Maximum  height:

96 in. (244 cm)

NOTE:

For installations requiring a longer drain hose, have a
qualified technician install a longer drain hose according
to your model number. For drain systems in the floor,
install a syphon break kit, P/N 5377678100. Both parts
are available from an authorized parts distributor.

an equipment-grounding conductor and a grounding plug, the
plug 

MUST

 be plugged into an appropriate, copper wired

receptacle that is properly installed and grounded in accordance
with all local codes and ordinances or in the absence of local
codes, with the National Electrical Codes,
ANSI/NFPA 70 (latest edition). If in
doubt, call a licensed electrician.

DO NOT

 cut off or alter the

grounding prong on the power
supply cord. In situations where a
two-slot receptacle is present, it is
the owner’s responsi-
bility to have a licensed electrician
replace it with a 

properly grounded

 three prong grounding type receptacle.

3.

For added personal safety, connect a separate ground wire (No.
18 minimum) from a top panel hinge screw on the rear of the
washer to a grounded cold water pipe. 

DO NOT

 ground to a gas

supply pipe or hot water pipe.

4.

Grounded cold water pipe 

MUST

 have metal continuity to

electrical ground and 

MUST

 register no more than 25 ohms

resistance. It 

MUST

 not be interrupted by plastic, rubber, or

other electrical insulating connectors such as hoses, fittings,
washers, gaskets (including water meter or pump). Any electrically
insulated connector should be jumped with a length of No. 4
copper wire securely clamped to bare metal at both ends with a
UL approved ground clamp.

5.

If a grounded water pipe is not available, a ground rod

 MUST

be used and register no more than 25 ohms resistance when in
the ground. Drive the rod into the ground outside the dwelling
and connect a grounding wire (12 AWG or heavier) between the
grounding screw and the grounding rod. It may take more than
one ground rod to not exceed 25 ohms resistance to ground.

WATER SUPPLY REQUIREMENTS

Hot and cold water faucets 

MUST

 be installed within 42 inches (107

cm) of your washer’s water inlet. The faucets 

MUST

 be 3/4 inch (1.9

cm) garden hose type so inlet hoses can be connected. Water pressure

MUST

 be between 10 and 120 pounds per square inch (maximum

unbalance pressure, hot vs. cold, 10 psi.) Your water department can
advise you of your water pressure. The hot water temperature should
be about 140 degrees F (60 degrees C).

ROUGH-IN DIMENSIONS

LID OPEN 90°

FRONT VIEW

SIDE VIEW

DRAIN
O U T L E T

DRAIN
O U T L E T
( R E A R )

WAT E R
I N L E T S
( R E A R )

27"

27"

3-3/4"

(129.54

cm)

(9.53 cm)

(68.58 cm)

(68.58 cm)

(74.77 cm)

29-7/16" (111.76

 cm)

44"

51"

11-7/16"

96" Max.
(244 cm)

33" Min.
(61 cm)

LOCATION OF YOUR WASHER

DO NOT INSTALL YOUR WASHER:

1.

In an area exposed to dripping water or outside weather
conditions. The ambient temperature should never be below
60 degrees F (15.6 degrees C) for proper washer operation.

2.

In an area where it will come in contact with curtains or drapes.

3.

In an area (garage or garage-type building) where gasoline of
other flammables are kept or stored (including automobiles).

4.

On carpet. Floor 

MUST BE SOLID

 with a maximum slope of 1 in.

(2.54 cm). To ensure vibration or movement does not occur,

REINFORCEMENT

 of the floor may be necessary.

IMPORTANT   MINIMUM INSTALLATION CLEARANCES

When installed in alcove:

Sides = 0" (0 cm),

Rear = 0" (0 cm), Top = 20" (50.8 cm).
When installed in closet:

Sides = 0" (0 cm),

Rear = 0" (0 cm), Top = 20" (50.8 cm), Front = 1"
(2.54 cm).
Closet door ventilation openings required:  2 louvers each 60 square
inches (387 cm

2

) — 3 inches (7.6 cm) from bottom and top of door.

(29.05 cm)

                                 UNPACKING

1.

Using the four shipping carton corner posts (two on each side),
carefully lay the washer on its left side and remove foam shipping
base.

2.

Using a ratchet with 3/8" socket, remove the mechanism shipping
bolt and plastic spacer block from the center of the base.

Summary of Contents for GLWS1749AS4

Page 1: ...installed correctly and safely Leave these instructions near the washer after installation for future reference NOTE The electrical service to the washer must conform with local codes and ordinances and the latest edition of the National Electrical Code ANSI NFPA 70 or in Canada CSA 22 1 Canadian Electrical Code Part 1 Avant de commencer lisez soigneusement cette notice pour simplifier l installat...

Page 2: ... to electrical ground and MUST register no more than 25 ohms resistance It MUST not be interrupted by plastic rubber or other electrical insulating connectors such as hoses fittings washers gaskets including water meter or pump Any electrically insulated connector should be jumped with a length of No 4 copper wire securely clamped to bare metal at both ends with a UL approved ground clamp 5 If a g...

Page 3: ...extension at a minimum to prevent excessive vibration The farther out the legs are extended the more the washer will vibrate 7 Form a U shape on the end of the drain hose with the hose pointed toward the drain On some models a wire retainer needs to be assembled on the hose in that position Place the formed end in a laundry tub or a standpipe and secure with a cable tie provided in the enclosure p...

Page 4: ... pression maximale eau chaude par rapport à eau froide 10 lb po2 Le service des eaux vous indiquera quelle est votre pression d eau La température de l eau chaude doit être supérieure à 60 degrés C 140 degrés F VIDANGES 1 La vidange doit pouvoir écouler 64 3 litres 17 gallons à la minute 2 Diamètre du tuyau de vidange 3 18 cm 1 1 4 po minimum 3 La hauteur du tuyau de vidange au dessus du sol doit ...

Page 5: ... ne doit pas être inférieure à 15 6 degrés C 60 degrés F pour que la laveuse fonctionne correctement 2 dans un lieu où elle viendrait en contact avec les rideaux 3 dans un lieu garage ou bâtiment de même type où essence ou autres produits inflammables sont conservés y compris les voitures 4 sur de la moquette Le sol DOIT ÊTRE SOLIDE avec une pente maximale de 2 54 cm 1 po Pour qu aucune vibration ...

Page 6: ...Pour s assurer que la laveuse est de niveau et bien stable sur ses quatre pieds ouvrez le couvercle saisissez le panneau supérieur et basculez la laveuse vers l avant pour que les pieds arrière quittent le sol Remettez doucement la laveuse en arrière pour que les pieds arrière se règlent d eux mêmes Placez un niveau sur le dessus de la laveuse Vérifiez d un côté à l autre puis de l avant à l arriè...

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Reviews: