Frigidaire GLGR341AS4 Installation Instructions Manual Download Page 5

5

ROUGH-IN DIMENSIONS

UNDER COUNTER & STACK MODELS

(2.54 cm)

REAR VIEW

36"

(91.5 cm)

(6.5 cm)

(9.5 cm)

ELECTRIC CONNECTION

13 1/2"

(34.4 cm)

(68.3 cm)

UNDER

COUNTER

34 5/8"

(87.9 cm)

3/8" (0.96 cm) DIA.

GAS PIPE

(68.6 cm)

3/4"

(1.9 cm)

SIDE VIEW

4 3/8"

(11.1 cm)

47 1/2"

(120.7 cm)

OPTIONAL

VENT KNOCKOUT

3 3/4"

(9.5 cm)

MOBILE HOME INSTALLATION

1. Dryer 

MUST

 be exhausted outside (outdoors, not beneath

the mobile home) using metal ducting that will not support
combustion. Metal ducting must be 4 inches (10.16 cm) in
diameter with no obstructions. Rigid metal duct is preferred.

2. If dryer is exhausted through the floor and area beneath

the mobile home is enclosed, the exhaust system 

MUST

terminate outside the enclosure with the termination
securely fastened to the mobile home structure.

3. When installing a gas dryer into a mobile home, a provision

must be made for outside make up air. This provision is to
be not less than twice the area of the dryer exhaust outlet.

4. This dryer 

MUST

 be fastened to the floor. Mobile Home

Installation Kit No. 169840 is available from your dealer.

5. Refer to pages 2 and 3 for other important venting

requirements.

6. Installation 

MUST

 conform to current Manufactured Home

Construction & Safety Standard (which is a Federal
Regulation Title 24 CFR-Part 32-80) or when such standard
is not applicable, with American National Standard for
Mobile Homes. In Canada, the CSA Z240 is applicable.

 The dryer is designed under ANSI Z 21.5.1 for

HOME USE

 only.

Summary of Contents for GLGR341AS4

Page 1: ...of Your Dryer 4 Mobile Home Installation 5 Rough In Dimensions 5 6 Unpacking 6 Reversing Door Swing 6 Electrical Installation 7 Grounding Requirements 7 Electrical Connections 3 wire 8 Electrical Connections 4 wire 8 Installation 9 Replacement Parts 9 Printed in U S A P N 134296400 0308 Installation Instructions Gas Electric Dryer Before beginning installation carefully read these instructions Thi...

Page 2: ...g the length of duct pipe or number of elbows allowed in the MAXIMUM LENGTH charts can cause an accumulation of lint in the exhaust system Plugging the system could create a fire hazard as well as increase drying times Do not screen the exhaust ends of the vent system nor use any screws or rivets to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging t...

Page 3: ... following method must be used to determine if the exhaust system is acceptable 1 Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer 2 Set the dryer timer and temperature to air fluff cool down and start the dryer 3 Read the measurement on the manometer 4 The system back pressure MUST NOT be higher than 0 75 inches of water column If the syst...

Page 4: ...es 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length of the door is acceptable MINIMUM INSTALLATION CLEARANCES Inches FRONT SIDES REAR TOP Alcove or Under counter 0 0 cm 0 0 cm 0 0 cm 15 38 1 cm Closet 1 2 54 cm 0 0 cm 0 0 cm ...

Page 5: ...enclosed the exhaust system MUST terminate outside the enclosure with the termination securely fastened to the mobile home structure 3 When installing a gas dryer into a mobile home a provision must be made for outside make up air This provision is to be not less than twice the area of the dryer exhaust outlet 4 This dryer MUST be fastened to the floor Mobile Home Installation Kit No 169840 is ava...

Page 6: ...screws 3 Rotate the door 180 and reinstall the door hinges to the dryer front panel with the four screws 4 Install the four hinge hole plugs in the open screw holes on the right side of the door opening UNPACKING 1 Using the four shipping carton corner posts two on each side carefully lay the dryer on its left side and remove foam shipping base To prevent damage do not use the control panel as a m...

Page 7: ... the equipment grounding terminal or lead on the appliance Canadian ELECTRIC Dryer DANGER Improper connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded For a grounded cord connected dryer 1 The dryer must be grounded In the event of a malfunction or breakdown g...

Page 8: ...dian ELECTRIC Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp power cord NEMA 10 30 Type SRDT through the strain relief 4 Attach t...

Page 9: ...so see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE On gas dryers before the burner will light it is necessary for the gas line to be bled of air If the burner does not light within 45 seconds the first time the dryer is turned on the safety switch will shut the burner off If this happen...