09/03
14
Publication No.
GLET1031CS0
5995396370
WIRING DIAGRAM
WHT
LID LOCK
CAUTION: DISCONNECT ELECTRIC CURRENT BEFORE SERVICING
ORG
8
DRYER TIMER
BRN
INDICATE CAM
CIRCLED NUMBERS
12
14
WASHER TIMER
T10
T13
T21
T24
CONNECTOR
TO NEUTRAL
GRAY
RED
M6
M2
M5
LOW
MOTOR
START
HIGH
11
6
LID SWITCH
RED/WHT
WHT/RED
WHT/BLK
WHT/PURP
BLK/RED
BLK/RED
4
TIMER
MOTOR
2
6
0
T3
T6
T11
T15
T14
PURP
BLUE
BLUE
T9
T22
T2
T4
T5
PINK
P.S. BYPASS
AGITATE DIR
AGITATE DIR
ADV. SOAK-WASH
HIGH SPEED MOTOR
P.S. BYPASS
LOW SPEED MOTOR
14
17
14 8
12 8
10
8
22
24
22
21
T
B
T
B
12
16
18
12
10
B
T
B
B
T
0°
T7
T20
T17
10
TAN/
BLK
BLK
SPIN DIR
BLK
EMPTY
YEL
CAPACITOR
TEMP SWITCH
F
FF
H
C
1
2
C
ORG
WATER
VALVE
H
PUMP
MOTOR
1
BLK/
RED
BLK/
RED
SWITCH
PRESSURE
35.25°
TAN/
3
FULL
111
°
98.25°
WHT
2
(16 MIN.)
WATER TEMP.
SI SPRAY
WASH FILL
RINSE FILL
LID SW BYPASS
O
C
A
V
T
2
E
8
4
2 1
0
M
C
A
I
7
9
10
4
3
B
T
B
T
T
1
3
X
E
F
I
D T
T
B
T
A
C
N
TERM. C
SPIN DIR
PUMP
CIRCUIT
WASH
REGULAR CYCLE
SPIN
PUMP
A
P
*
P
RINSE
P
PUMP
SPIN
OFF
HOT WASH/COLD RINSE, AND
PRESSURE SWITCH FULL.
A PULSER CAM, LOCATED NEXT TO THE BUZZER
CAM AND ROTATING AT 12 REVELUTIONS PER
HOUR, ALLOWS CURCUIT "X-H" TO CLOSE FOR
A
1 OR 2 TIMES IN THIS AREA
B
6 TO 8 TIMES IN THIS AREA
START
SWITCH
CONNECTOR
BUZZER X-H
TIMER X-TM
HEATER B-A
MOTOR B-C
CIRCUIT
M7
M1
M3
TO L1
X=CLOSED
5 SECONDS (±3 SECONDS)
0= OPEN
SOAK
SOAK CYCLE
(12 MIN.)
SELECTOR SWITCH AT HIGH HEAT.
ELECTRICAL CODES.
BRANCH CIRCUIT.
1. ALL WIRING MUST CONFORM TO LOCAL
2. CONNECT DRYER TO 30 AMP INDIVIDUAL
AN THERMOSTAT CLOSED. AND FABRIC
TEMPERATURE SELECTOR SWITCH AT
DOOR SWITCH CLOSED, MOTOR AT REST,
WASHER TIMER SHOWN IN ON POSITION
3. DRYER TIMER SHOWN IN OFF POSITION
CHASSIS (CABINET) GROUND
MOTOR PROTECTOR
MOTOR SWITCH
NO CONNECTION
SCREW TERMINAL
QUICK DISCONNECT TERMINAL
PLUG IN TIMER TERMINAL
WIRING CODES
CONNECTION
SPLICE
INSULATED TERMINAL
HARNESS CONNECTOR TERMINAL
TIMER PLUG-MALE
(END VIEW)
18
17
16
23
22
20
19
24
21
14
13
11
10
15
12
8
7
5
2
4
1
9
3
6
SUBINTERVAL SPRAY DETAIL
SPRAY TO OCCUR DURING
THE INDICATED INTERVAL
TEMPERATURE SWITCH CIRCUIT
CONNECTION
TO DRYER L1
CONNECTOR
BLK
WASH/RINSE
COLD/COLD
HOT/COLD
WARM/COLD
WARM/WARM (OPT)
TO DRYER NEUTRAL
139.75°
WHT
204.75°
191.75°
NOTES;
30±2 SEC
10±2 SEC
222°
120 SEC
285.75°
291.255°
273.5°
(6 MIN.)
RINSE
PERM. PRESS CYCLE
WASH
(12 MIN.)
SPIN
PUMP
P
P
PUMP
SPIN
P
*
OFF
DELICATE CYCLE
SPIN
PUMP
WASH
A
P
P
RINSE
P
OFF
PUMP
SPIN
W
ASH
344.75°
360°
OFF
P
R
E
I
N
S
SPIN
PUMP
START
RUN
THERMOSTAT
HIGH LIMIT
WHT
IN ALL MODELS.
CIRCUITS THAT ARE NOT
DASHED LINES INDICATE
NOTE:
4
HEATER, 10K
THERMOSTAT
FABRIC
SWITCH
SELECTOR
RED
BLUE
5
3
3K
3
1
LAMP
DRUM
BUZZER
B
X
YEL
R
A
1
4.4K
TM
H
BLK
C
L2
BLK
120 VAC
LIMITER
THERMAL
TIMER
MOTOR
2
ORG
ORG
BRN
WHT
THERMOSTAT
CONTROL
PURP
TAN
TAN
ORG/BLK
BRN
WHT
GRN
WHT
N
240 VAC
WHT
X=CLOSED 0=OPEN
FABRIC SELECTOR SWITCH
4500 WATTS
HEATER
BLK
SWITCH
MOTOR
M4
NC
DOOR
M6
M5
GRAY
NO
RED
GRN
M2
M1
GRAY
CRADLE
MOTOR
C
120 VAC
RED/BLK
RED
RED
POSITION
HIGH HEAT
MEDIUM HEAT
NO HEAT
LOW HEAT
X
X
1-2
X
O
L1
O
X
O
O
3-4
O
O
4-5
O
X
FF-H
F-H
O
X
O
X
O
O
O
X
X
X
FF-C
O
X
THE BAR CHART ABOVE REPRESENTS ONE
A
A
B
COMPLETE REVOLUTION OF TIMER SHAFT.
SHADED PORTION OF BAR CHART INDICATES
THE PROPORTIONAL TIMES THAT INTERNAL
TIMER CONTACTS ARE CLOSED.
AUTO DRY
20
30
OFF
CYCLES
TIMED DRY (MIN)
OFF
0
10
60
74
40
0
20
30
WRINKLE RID
AUTO DRY
45
OFF
15
0
WIRING DIAGRAM
134134500
Summary of Contents for GLET1031C
Page 2: ...09 03 2 Publication No GLET1031CS0 5995396370 UPPER CABINET DRUM HEATER ...
Page 4: ...09 03 4 Publication No GLET1031CS0 5995396370 MOTOR BLOWER BELT ...
Page 8: ...09 03 8 Publication No GLET1031CS0 5995396370 LOWER CABINET TOP ...
Page 12: ...09 03 12 Publication No GLET1031CS0 5995396370 TRANSMISSION ...