ROUGH-IN DIMENSIONS

ROUGH-IN DIMENSIONS

ROUGH-IN DIMENSIONS

ROUGH-IN DIMENSIONS

ROUGH-IN DIMENSIONS

UNDER COUNTER & STACK MODELS

(2.54 cm)

(2.54 cm)

(2.54 cm)

(2.54 cm)

(2.54 cm)

REAR VIEW

REAR VIEW

REAR VIEW

REAR VIEW

REAR VIEW

36"

36"

36"

36"

36"

(91.5 cm)

(91.5 cm)

(91.5 cm)

(91.5 cm)

(91.5 cm)

(6.5 cm)

(6.5 cm)

(6.5 cm)

(6.5 cm)

(6.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

ELECTRIC CONNECTION

ELECTRIC CONNECTION

ELECTRIC CONNECTION

ELECTRIC CONNECTION

ELECTRIC CONNECTION

13 1/2"

13 1/2"

13 1/2"

13 1/2"

13 1/2"

(34.4 cm)

(34.4 cm)

(34.4 cm)

(34.4 cm)

(34.4 cm)

(68.3 cm)

(68.3 cm)

(68.3 cm)

(68.3 cm)

(68.3 cm)

UNDER

UNDER

UNDER

UNDER

UNDER

COUNTER

COUNTER

COUNTER

COUNTER

COUNTER

34 5/8"

34 5/8"

34 5/8"

34 5/8"

34 5/8"

(87.9 cm)

(87.9 cm)

(87.9 cm)

(87.9 cm)

(87.9 cm)

3/8" (0.96 cm) DIA.

3/8" (0.96 cm) DIA.

3/8" (0.96 cm) DIA.

3/8" (0.96 cm) DIA.

3/8" (0.96 cm) DIA.

GAS PIPE

GAS PIPE

GAS PIPE

GAS PIPE

GAS PIPE

(68.6 cm)

(68.6 cm)

(68.6 cm)

(68.6 cm)

(68.6 cm)

3/4"

3/4"

3/4"

3/4"

3/4"

(1.9 cm)

(1.9 cm)

(1.9 cm)

(1.9 cm)

(1.9 cm)

SIDE VIEW

SIDE VIEW

SIDE VIEW

SIDE VIEW

SIDE VIEW

4 3/8"

4 3/8"

4 3/8"

4 3/8"

4 3/8"

(11.1 cm)

(11.1 cm)

(11.1 cm)

(11.1 cm)

(11.1 cm)

47 1/2"

47 1/2"

47 1/2"

47 1/2"

47 1/2"

(120.7 cm)

(120.7 cm)

(120.7 cm)

(120.7 cm)

(120.7 cm)

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

VENT KNOCKOUT

VENT KNOCKOUT

VENT KNOCKOUT

VENT KNOCKOUT

VENT KNOCKOUT

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

MOBILE HOME INST

MOBILE HOME INST

MOBILE HOME INST

MOBILE HOME INST

MOBILE HOME INSTALLA

ALLA

ALLA

ALLA

ALLATION

TION

TION

TION

TION

1. Dryer MUST

MUST

MUST

MUST

MUST be exhausted outside (outdoors, not beneath

the mobile home) using metal ducting that will not support
combustion. Metal ducting must be 4 inches (10.16 cm) in
diameter with no obstructions. Rigid metal duct is preferred.

2. If dryer is exhausted through the floor and area beneath

the mobile home is enclosed, the exhaust system MUST

MUST

MUST

MUST

MUST

terminate outside the enclosure with the termination
securely fastened to the mobile home structure.

3. When installing a gas dryer into a mobile home, a provision

must be made for outside make up air. This provision is to
be not less than twice the area of the dryer exhaust outlet.

4. This dryer MUST

MUST

MUST

MUST

MUST be fastened to the floor. Mobile Home

Installation Kit No. 169840 is available from your dealer.

5. Refer to pages 2 and 3 for other important venting

requirements.

6. Installation MUST

MUST

MUST

MUST

MUST conform to current Manufactured Home

Construction & Safety Standard (which is a Federal
Regulation Title 24 CFR-Part 32-80) or when such standard
is not applicable, with American National Standard for
Mobile Homes. In Canada, the CSA Z240 is applicable.

 The dryer is designed under ANSI Z 21.5.1 for

HOME USE

HOME USE

HOME USE

HOME USE

HOME USE only.

Summary of Contents for GLER642CAS2

Page 1: ...vice to the Dryer must conform with local codes and ordinances and the latest edition of the The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the The electrical service to the Dryer must conform with local codes and ordinances and ...

Page 2: ... the outside dryer exhaust system MUST be exhausted to the outside dryer exhaust system MUST be exhausted to the outside of the dwelling of the dwelling of the dwelling of the dwelling of the dwelling Do not allow combustible materials for example clothing draperies curtains paper to come in contact with exhaust system The dryer MUST NOT MUST NOT MUST NOT MUST NOT MUST NOT be exhausted into a chim...

Page 3: ...st pressures equal to or less than 1 2 psig 3 45 kPa INSTALL MALE FITTINGS IN CORRECT DIRECTION In installations where the exhaust system is not described in the charts the following method must be used to determine if the exhaust system is acceptable 1 Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer 2 Set the dryer timer and temperature t...

Page 4: ...ION CLEARANCES Inches TION CLEARANCES Inches TION CLEARANCES Inches TION CLEARANCES Inches TION CLEARANCES Inches FRONT SIDES REAR TOP Alcove or Under counter 0 0 cm 0 0 cm 0 0 cm 15 38 1 cm Closet 1 2 54 cm 0 0 cm 0 0 cm 15 38 1 cm Closet door ventilation required 2 louvered openings each 60 square inches 387 square centimeters 3 inches 7 6 cm from bottom and top of door THIS DRYER MUST BE EXHAUS...

Page 5: ...UT 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 9 5 cm 9 5 cm 9 5 cm 9 5 cm 9 5 cm MOBILE HOME INST MOBILE HOME INST MOBILE HOME INST MOBILE HOME INST MOBILE HOME INSTALLA ALLA ALLA ALLA ALLATION TION TION TION TION 1 Dryer MUST MUST MUST MUST MUST be exhausted outside outdoors not beneath the mobile home using metal ducting that will not support combustion Metal ducting must be 4 inches 10 16 cm in diameter wit...

Page 6: ...lly lay the dryer on its left side and remove foam shipping base To prevent damage do not use the control panel as a means to pick up or move the dryer NOTE NOTE NOTE NOTE NOTE On under counter model clothes dryers the top panel may be removed for installation 2 Return the dryer to an upright position PACKING FOAM SHIPPING REMOVE 4 SCREWS ONE FROM EACH HINGE FIRST ROUGH IN DIMENSIONS ROUGH IN DIME...

Page 7: ...ower cord with a copper wired receptacle power cord with a copper wired receptacle power cord with a copper wired receptacle NOTE NOTE NOTE NOTE NOTE Dryers operating on 208 volt power supply will have longer drying times than operating on 240 volt power supply For a permanently connected dryer 1 The dryer MUST MUST MUST MUST MUST be connected to a grounded metal permanent wiring system or an equi...

Page 8: ...Non Canadian ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC Dryer Dryer Dryer Dryer Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L approved strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a U L approved 30 amp ...

Page 9: ...ircuit breaker fuse box before plugging the power cord into the outlet 5 Turn on the power at the circuit breaker fuse box Before operating the dryer make sure the dryer area is clear and free from combustible materials gasoline and other flammable vapors Also see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for ...

Reviews: