background image

Summary of Contents for GLEQ2170KE0

Page 1: ...Installation instructions Instrucciones de Instalaci6n www frigidaire com P N 137111500B 0903 ...

Page 2: ...l code C22 1 part 1 The gas service to the dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas Code ANSI Z223 1 or in Canada CAN ACG B149 1 2000 The dryer is designed under ANSI Z 21 5 1 or ANSI UL 2158 CAN CSA C22 2 No 112 latest editions for HOME USE only This dryer is not recommended for commercial applications such as restaurants beauty salons etc...

Page 3: ...d 3 wire receptacle NEMA type 10 30R The dryer MUST employ a 3 conductor power supply cord NEMA 10 30 type SRDTrated at 240 volt AC minimum 30 amp with 3 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers For 3 wire cord connection instructions see ELECTRICALCONNECTIONS FORA 3 WIRE SYSTEM 4 WIRE POWER SUPPLY CORD KIT not supplied 4 wir...

Page 4: ... pressures equal to or lessthan 1 2 psig 3 45 kPa 8 Connections for the gas supply must comply with the Standard for Connectors for Gas Appliances ANSI Z21 24 Exhaust system requirements Use only 4 inch 10 2 cm diameter minimum rigid or flexible metal duct and approved vent hood which has a swing out damper s that open when the dryer is in operation When the dryer stops the dampers automatically c...

Page 5: ...st ends of the vent system or use any screws rivets or other fasteners that extend into the duct to assemble the exhaust system Lint can become caught in the screen on the screws or rivets clogging the duct work and creating a fire hazard as well as increasing drying times Use an approved vent hood to terminate the duct outdoors and seal all joints with duct tape All male duct pipe fittings MUST b...

Page 6: ...bow directly to exhaust outlet of dryer Dryer vent elbows are available through your local parts distributor or hardware store See also CLEARANCE REQUIREMENTS on the next page Use of 90 quick turn elbow required to meet mini mum installation depth of free standing dryer Straight back venting allows for 0 0 cm installation Venting right with 90 elbow allows for 0 75 2 cm installation Venting downwa...

Page 7: ...dryer in a closet with a solid door 4 Closet door ventilation required A minimum of 120 square inches 774 2 cm2 of opening equally divided at the top and bottom of the door is required Openings should be located 3 inches 7 6 cm from bottom and top of door Openings are required to be unobstructed when a door is installed A Iouvered door with equivalent air openings for the full length of the door i...

Page 8: ...ward venting of exhaust on pedestal mounted dryer adds approximately 2 25 in 5 7 cm to installation depth _ _ 48 25 122 5cm to clear open door 27 0 68 5cm 0 electrical supply on rear of unit c_ _enterline height for rear vent 19 0 48cm 3 75 _ _l 9 5cm _ 13 50 _ 34 5cm to center of rear vent gas supply pipe on of gas unit l 27 0 68 5cm 0 0 electrical supply on rear of unit centerline height for rea...

Page 9: ...ck Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded For a grounded cord connected dryer 1 The dryer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical current 2 After you purchase and install a 3 wire or 4 wire power supply cord having an eq...

Page 10: ...e to the 3 8 inch 0 96 cm pipe located on the back of the dryer Use a 1 2 inch to 3 8 inch 1 27 cm to 0 96 cm reducer for the connection Apply an approved thread sealer that is resistant to the corrosive action of liquefied gases on all pipe connections Manual GAS FLOW Shutoff Flare _ Flare Valve Union Union 1 1 los R Nipple Flexible Inlet Plpeon Open Connector Back of Dryer All connections must b...

Page 11: ...VER colored center terminal on the terminal block Tighten the screw securely 6 Attach the remaining two power cord outer conductors to the outer BRASScolored terminals on the terminal block Tighten both screws securely ELECTRICAL SHOCK HAZARD Do not make a sharp bend or crimp wiring conductor at connections 7 Follow manufacturer s guidelines for firmly securing the strain relief and power cord 8 R...

Page 12: ...ove the internal dryer harness ground BLACK wire to the terminal block and attach it along with the neutral WHITE power cord wire conductor to the center SILVER colored terminal on the terminal block Tighten the screw securely 8 Attach the REDand BLACK power cord conductors to the outer BRASScolored terminals on the terminal block Tighten both screws securely ELECTRICAL SHOCK HAZARD Do not make a ...

Page 13: ... and discard door tape Be sure the power is off at a circuit breaker fuse box before plugging the power cord into an outlet 3 Plug the power cord into a grounded outlet 4 Turn on the power at the circuit breaker fuse box 5 Read the Use Care Guide provided with the dryer It contains valuable and helpful information that will save you time and money 6 If you have any questions during initial operati...

Page 14: ...nt panel Figure 2 For best results start by only removing one screw per hinge Then only loosen the two remaining screwswhile firmly holding door to prevent damage to hinge front panel or door_After the remaining screwsare loosened continue to remove all Figure 3 Figure 5 6 Pull handle away from door assembley Figure 5 Figure 6 7 Separatethe outer door from the inner door assemblywith a putty knife...

Page 15: ...install in hole striker was just removed 17 Install striker included in literature bag into hole square plug was previously installed Figure 9 Figure 10 10 Remove two 2 transition ring plugs and reinstall on previous handle side Figures 9 and 1O Figure 12 18 Reinstall door handle by placing the handle mounting bosses through holes in lens and transition ring and installing screws through inner doo...

Page 16: ...installation MOBILE HOME iNSTALLATiON KiT P N137067200 Installations in mobile homes require use of MOBILE HOME INSTALLATIONKIT S 00 DRYING RACK P N137067300 Depending on the model you purchased a drying rack may have been included in the initial purchase of your dryer If your model did not include a drying rack or you desire another drying rack you may order one UNIVERSAL APPLIANCE WRENCH P N1370...

Page 17: ...rvicio de gas de la secadora debe cumplir con los codigos y las ordenanzas locales y la ultima edicion del Codigo de Gas Nacional National Fuel Gas Code el ANSI Z223 1 o bien en Canada1 el CAN CGA B149 1 2000 La secadora se diseflo conforme a los codigos ANSI Z 21 5 1 o ANSI UL 2158 CAN CSA C22 2 N 112 ultimas edicio nes solo para USO DOMESTICO No se recomienda esta secadora para uso comercial com...

Page 18: ...lectrica de 3 conductores tipo NEMA 10 30 SRDT calificado para CA minima de 240 voltios 30 amp con 3 conectores de terminal horquilla con extremos doblados hacia arriba o de bucle cerrado y calificados para uso en secadoras de ropa Paraobtener instrucciones sobre a conexi0n trifilar consulte CONEXIONESELECTRICASPARA UN SISTEMATRIFILAR CABLE DE ALIMENTAClON ELECTRICA TETRAFILAR no incluido Receptac...

Page 19: ...s ANSI Z21 24 Requisitos del sistema de escape Utilice solo un conducto de metal flexible o rigido de 10 2 cm 4 pulgadas de diametro minimo y una capucha de ventilaci0n aprobada que tenga uno o mas reguladores de tiro que se abran cuando a secadora este en funcionamiento Cuando la secaclora se detiene el regulador de tiro se cierra automaticamente para evitar a corriente de aire y el ingreso de in...

Page 20: ...teniendo en cuenta el flujo de aire PELIGRO DE INCENDIO No permita que materiales combustibles pot ejemp o ropa tapiceria cortinas pape entren en contacto con el sistema de escape La secadora NO DEBEtenet escape a una chimenea una pared un techo ni ningun espacio cerrado de un edificio que pueda acumular pelusa y cons tituir un peligro de incendio No bloquee los extremos de escape de sistema de ve...

Page 21: ...buidor de repuestos o ferreteria local Consulte tambien los REQUISITOSDE DESPEJE en la siguiente p_figina Utilice un codo de giro r_ipido de 90 para cumplir con la profundidad minima de instalacion de la secadora independiente Laventilacion derecho hacia atr_is permite la instalacion de la secadora a 0 0 cm de la pared Laventilacion hacia la derecha con un codo de 90 permite la instalacion de la s...

Page 22: ...4 Ventilacion requerida en la puerta del armario Se necesita un minimo de 774 2 cm2 120 pulgadas 2 de abertura dividido en partes iguales en la parte superior e inferior de la puerta Las aberturas de ventilaci0n deben estar ubicadas a 7 6 cm 3 pulgadas de la parte superior e inferior de la puerta Esnecesario que las aberturas de aire no esten obstruidas al instalar una puerta Se acepta una puerta ...

Page 23: ...rox madamente en 2 25 5 7 cm _ 27 0 _ _ 68 5cm 0 _ _p _P 13 50 _ 34 5cm hac a e centro de _a ventHac _n trasera surn n stro e _ctrico en la parte trasera de a unidad a tura de a nea centra ara ventHaci6n trasera 3 7 _i 19 5cm1 19 0 48cm _ 48 25 122 5cm para destapar abra _a puerta _ 30 5 77 5cm a frente de _a puerta cerrada m _ m m _ m _ m B m _ m _ m _ _ 71 5 182cm tuber a de suministro de gas en...

Page 24: ...igro de descargaelectrica Si no est 1seguro de haber realizado correctamente la conexiOna tierra del artefacto consulte a un electricista autorizado Para una secadora conectada a tierra 1 La secadora DEBEtenet conexion a tierra En el caso de que la secadora no funcione correctamente o se descomponga la conexion a tierra reduce el riesgo de descarga electrica porque ofrece una trayectoria de menor ...

Page 25: ... traves de la tuberia Espere unos minutos a que el gas fluya a traves de la linea de suministro de gas Conecte un tubo aprobado o uno semi rigido de 1 27 cm 1 2 pulgada de dbimetro interior desde la linea de suministro de gas al tubo de 0 96 cm 3 8 pulgada ubicado en la parte trasera de la secadora Utilice un reductor de 1 27 cm a 0 96 cm 1 2 pulgada a 3 8 pulgada para realizar la conexion Aplique...

Page 26: ... Ajuste el tornillo con firmeza Conecte los dos conductores externos restantes del cable de alimentacion a los terminales externos de color LATON del bloque terminal Ajuste los dos tornillos con firmeza PELIGRODE DESCARGA ELE CTRICA No forme un _ingulo agudo con el cableado conductor ni los doble en el punto de conexion 7 Siga las pautas del fabricante para sujetar firmemente el dispositivo de lib...

Page 27: ...eva el cable interno NEGRO de conexi6n a tierra que integra el enchufe preformado de la secadora al bloque terminal y conectelo junto con el conductor neutro BLANCO del cable de alimentacion al terminal PLATEADOdel centro del bloque terminal Ajuste el tornillo con firmeza Conecte los conductores ROJOy NEGROdel cable de alimentacion a los terminales externos de color LATON del bloque terminal Ajust...

Page 28: ...ja del interruptor autom_itico fusibles para asegurarse de que la electricidad este desconec tada antes de conectar el cable de alimentacion al tomaco rriente 3 Conecte el cable de alimentacion a un tomacorriente con conexion a tierra 4 Conecte la electricidad desde la caja del interruptor autom_itico fusi hies s Consulte laGu a de uso ycuidado que se proporciona con la secadora Dicha guia contien...

Page 29: ... Figura 2 Para mejores resultados quite solo uno de los tomillos Luego quite los dos restantes mientras sujeta la puerta firmemente para evitar que caiga y cause un dan o a la bisagra a Panel o a la Puerta Despues de aflojar los tornil os restantes proceda a quitarlos completamente Figure 3 Figure 5 6 Retire la manija lejos de ensamble de la puerta Figura 5 3 Coloque la Puerta con el lado de la bi...

Page 30: ...en el agujero donde estaba la contra 17 Instale la contra mismo que se proporciona en la bolsa de la Literatura en el agujero cuadrado en donde quito el tapon Figure 9 Figure 10 10 Quite dos 2 tapones del anillo de transici6n y reinst_lese en lado anterior de la manija Figuras 9 y 10 Figure 12 18 Re instale la manija de la Puerta haciendo pasar los pernos de montaje de la misma a traves de los agu...

Page 31: ...bricante puede ocasionar lesiones perso nales daflos a la propiedad o daflos a la secadora 00 S 00 REJILLA DE SECADO PiezaNo 1370067300 Dependiendo del modelo que haya comprado es posible que esta secadora incluya una rejilla de secado Si el modelo que adquirio no incluye una rejilla de secado o desea una rejilla adicional puede pedir una LLAVE UNIVERSAL PARA ELECTRODOMESTICOS PiezaNo 137019200 Ta...