background image

CANADA

 

 5855 Terry Fox Way 

 Mississauga, ON L5V 3E4 

 1-800-265-8352 

 

frigidaire.ca

CGBM185KF  10/11 

© 2011 Electrolux Major Appliances, NA 

Printed in Canada

Microwaves

CGBM185KF    

30" Over-The-Range

Microwave Specifications

 Product Shipping Weight (approx.) – 69 Lbs.

 Voltage Rating – 120V / 60 Hz / 15 Amps

 Connected Load (kW Rating) @ 120 Volts = 1.65 kW 

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

 Amps @ 120 Volts = 14.3 Amps

 Always consult local and national electric codes.

 Grounded outlet should be located in cabinet above, with hole in base 

to route power cord. Carefully follow top template instructions for 

power cord clearance when installing beneath smooth, flat cabinets.

 Microwave’s exhaust ventilation system is preset to recirculate air 

inside with no ducting system required. Exhausting air outside is 

optional, using either vertical or horizontal ducting system. 

(Refer to 

Ducted Option Specifications for outside ventilation.)

 For safe and proper installation, microwave MUST be mounted to 

BOTH a top cabinet AND a wall, and connected to at least one wall 

stud. Can NOT be installed in island or peninsula cabinet arrangements.

 Cabinet bottom MUST be level to insure proper installation.

 Cabinet MUST be capable of supporting a total load of 110 lbs.

 Filler blocks recommended for installation when cabinet front hangs 

below recessed bottom shelf.

 Minimum distance of 30" required from cooking surface to bottom 

edge of top cabinet.

 Minimum distance of 66" required from floor to top of microwave.

 Opening between cabinets MUST be 30" wide and free of obstructions. 

For openings up to 36" wide, order optional 36" Filler Panel Kit to fill  

in gap between unit and cabinets.

 Allow 26" minimum clearance for 90° door swing.

Ducted Option Specifications

 For outside ventilation.

 Exhaust duct adapter will be needed for outside ventilation, to mate 

with standard 3-1/4" x 10" rectangular duct. If round duct required, 

rectangular-to-round transition adapter will be needed with no less 

than 6" diameter.

 For most efficient airflow exhaust, use a straight run or as few elbows 

as possible with a maximum duct length of 3-1/4" x 10" rectangular or 

6" diameter round duct, not to exceed 140 equivalent feet.

 For horizontal installation, be sure to allow enough space between 

wall studs to accommodate exhaust.

 Refer to installation instructions on web for detailed duct 

preparation and converting exhaust vent blower system for exterior 

exhaust ventilation.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.ca for detailed instructions.

30" Over-the-Range Microwave Oven w/Bottom Controls

Gallery (1.8 Cu. Ft.)

16 ¾"

13

Specificationssubjecttochange.

Accessoriesinformationavailable

onthewebat

frigidaire.ca 

Reviews: