background image

Summary of Contents for FSC09CH7M

Page 1: ...SPLIT TYPE ROOM AIR CONDITIONER OWNER S MANUAL utions carefully and thoroughly before From the Electrolux Group ...

Page 2: ...conditioner is for domestic use only It is not reccomended for commercial or industrial use The air conditioner you have may carry a different plug than the one illustrated in this manual The plug that comes with the product follows the electrical specification of the country where it is sold Contents Safety precaution 03 Installation 07 Part list 09 Indoor unit installation 11 Outdoor unit instal...

Page 3: ...ay cause electric shock 8 Do not allow water to run into electric parts It may cause failure of machine or electric shock 9 Do not drink water drained from air conditioner It contains contaminants and could make you sick 10 Do not use the power cord close to heating appliances It may cause fire and electric shock 11 Do not damage or use an unspecified power cord It may cause electric shock or fire...

Page 4: ...ehold furniture 25 Donotplace obstacles around air inlets orinside ofair outlet Itmaycause failure ofappliance oraccident 26 Turn offthemain power switch when notusing theunitforalong time Itmaycause failure ofproduct or fire 27 Donotusestrong detergent such aswaxorthinner Usea softcloth forcleaning Appearance maybedeteriorated duetochange ofproduct color or scratching ofitssurface 28 Ensure thatt...

Page 5: ...al that the unit be installed at the center of the environment 6 It must be far from fire smoke or flammable gases 7 The indoor unit must be at least 2 3 meters 7 5 feet from the ground 8 The site must allow for the easy removal of the connector pipe and drain hose 9 The unit must be installed at a site protected from direct sunlight More than 12cm More than 15cm More than 230cm More than 12cm Out...

Page 6: ...30cm A More than 60cm B C More than 200cm Outdoor Unit The indoor unit should be installed no lower than 2 3 m The pipe needs the minimun of 4 or 5 meters this distance will contribute to avoid vibration or noise Two of the three direction above A B C should be not be blocker The copper pipe can be isolated independent ...

Page 7: ...ly to outdoor side 2 Always use wal hole conduit when drilling metal grid metal plate or the like Wall Indoorunit _ I Outd r unit l Connective pipe and drainage installation Drainage 1 Run the drain hose sloping downward Do not install the drain hose as illustrated beside 2 When connection extension drain hose insulate the connecting part of extension drain hose with a shield pipe Connection pipe ...

Page 8: ...lowest side of the bundle Locating at the upper side can cause drain pan to overflow inside the unit 6 Never intercross nor intertwist the power wire with any other wiring 7 Run the drain hose sloped downward to drain out the condensed water smoothly 13 Outdoor unit installation 1 Install the outdoor unit on a rigid base to prevent increasing noise level and vibration 2 Determine the air outlet di...

Page 9: ... the flaring work Carry out correct flaring work sing the following procedure 1 2 3 Cut the pipes and the cable A Use the piping kit accessory or pipes purchased locally B Measure the distance between the indoor and the outdoor unit C Cut the pipes a little longer than the measured distance D Cut the cable 1 5m longer than the pipe length Burr removal A Completely remove all burrs from the cut cro...

Page 10: ...client until the problem is solved 2 Power voltage should be in the range of 90 110 of rated voltage 3 The creepage protector and main power switch with a 1 5 times capacity of Max Current of the unit should be installed in power circuit 4 Ensure the air conditioner is grounded well 5 According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect the wi...

Page 11: ...ric parts cover from the outdoor unit 2 Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units 3 To prevent the ingress of water from a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units 4 Insulate unused cords conductors with PVC tape Process them so they ...

Page 12: ...and moisture that remain in the refrigeration system have undesirable effects as detailed below 1 Pressure in the system rises 2 IOperating current rises 3 Cooling or heating efficiency drops 4 TMoisture in the refrigerant circuit may freeze and block capillary tubing 5 VVater may lead to corrosion of parts in the refrigeration system 6 Therefore the indoor unit and tubing between the indoor and o...

Page 13: ...e 8 Fully open the packed valve stems B and A 9 Securely tighten the cap of the packed valve Indoor unit Outdoor unit Manifold valve 76cm Hg Charge hose Hancle Io handle hi _ Charge hose Vacuum pump Electricel sefety Check the electrical safety before finalizing the installation 1 The insulation resistance must be higher than 2Q 2 Grounding After completing this step measure its resistance with a ...

Page 14: ...ioned safety norms 3 Before operating the air conditioner ensure that the air filter is installed correctly 4 If the unit has been out of use for a long period of time it is recommended that the air filter be cleaned before use During continuous use clean the air filter every two weeks 5 This air conditioner was designed for use under the following conditions The button for the manuaI control of t...

Page 15: ...et Air inlet Air outlet Indoor unit Outdoor unit Display panel indoor unit infrared signal receptor Auto When you set the air conditioner to AUTO mode the indicator starts flashing Defrost only heating model This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation Fan only When you set the air conditi...

Page 16: ...rfections 4 Keeps the remote control far from EMI electromagnetic interferences produced by other machines Install replace batteries The remote controller uses two alkaline dry batteries R03 LR03X2 1 To install batteries slide back the cover of the battery compartment and install the batteries according to the directions and show on the remote controller 2 To replace the old batteries use the same...

Page 17: ...ver swings for a certain angle for each press If keep pressing the button for more than 2 seconds the Auto swing feature will be activated Press it again the louver stops moving When the louver swing at a position which would affect the cooling and heating effect of the air conditioner it would automatically change the swing direction Not applicable to units without this function LED DISPLAY Press...

Page 18: ...ir conditioner works AUTOMATIC OPERATION Switch on the power and the OPERATION indication lamp on the display panel of the indoor unit starts flashing and turns off after flashes for 6 times 1 Use the MODE button to select AUTO 2 Push the TEMP button to set the desired room temperature The most comfortable temperature settings are between 21C o to 28C 3 Push the ON OFF button to start the air cond...

Page 19: ... the remote controller shows TIMER ON the last set time for the starting operation and the signal h will be shown on the DIGITAL DISPLAY area You are now ready to reset the time to START the operation 2 Push the TIMER ON button again to set desired unit start time 3 After setting the TIMER ON there will be a one half second delay before the remote controller transmits the signal to the air conditi...

Page 20: ...select a time you want to start your air conditioner 5 Do not put any object near air inletx or air outlet as the efficiency of the air conditioner may be reduced and the air conditioner may stop running 6 Clean the air filter periodically otherwise cooling or heating performance may be reduced 7 Do not operate unit with horizontal louvre in closed position f 37 Adjust the air flow direction prope...

Page 21: ...ximately 10 seconds Open angle of the horizontal louver should not be set too small as COOLING or HEATING performance may be impaired due to too restricted air flow area Do not operate unit with horizontal louver in closed position When the air conditioner is connected to power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation Manual operation Manua...

Page 22: ... 2 A cloth dampened with cold water may be used on the indoor unit if it is very dirty 3 The front panel of the indoor unit can be removed and cleaned with water Then wipe it with a dry cloth 4 Do not use a chemically treated cloth or duster to clean the unit 6 Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform If you...

Page 23: ...from the indoor unit This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off smells permeated from building material from furniture or smoke Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity...

Page 24: ...cal and Electronic Equipment guidelines waste from electrical and electronic devices should be collected separately If you need to dispose of this appliance in the future do NOT throw it away with the rest of your domestic garbage Instead please take the appliance to the nearest WEEE collection point where available If the trouble has not been corrected please contact a local dealer or the nearest...

Page 25: ... 20000 220 230 6O 275 928 198 10 540 780 250 35 Cool heat 24000 28000 220 230 60 3 3 1030 221 14 5 695 845 335 57 Cooling only type Cycle Cooling power Btu h Rated Voltage V Frequency Hz Indoor unit high mm Indoor unit width ram Indoor unit depth ram indoor unit net weight kg Outdoor unit high mm Outoor unit width mm Outdoor unit depth mm Outdoor unit net weight kg Cool 9000 220 240 50 190 790 275...

Page 26: ...78O 25O 34 Cool 24000 220 230 6O 3 3 1030 221 14 5 695 845 335 56 Heating cooling type Cycle Cooling power Btu h Heating power Btu h Rated Voltage V Frequency Hz Indoor unit high mm Indoor unit width mm Indoor unit depth mm Indoor unit net weight kg Outdoor unit high mm Outdoor unit width mm Outdoor unit depth mm Outdoor unit net weight kg Cool heat 9000 9000 220 230 6O 275 79O 190 8 5 43O 685 26O...

Page 27: ......

Reviews: