SS-FRS093LS1-07/10-1
POWER
Circuit Amps
Maximum Fuse Size
CAPACITIES
Cooling
Amps
Watts
Min/Max Cooling
SEER
EER
Low Ambient Temperature
Voltage/Frequency/Phase
Dehumidification
INDOOR UNIT
Sound Rating
Net Weight
Shipping Weight
Dimensions (H x W x D)
Full Loaded Amps
Number of Fan Speeds
Fan Type
Motor Watts
Full Loaded Amps
COMPRESSOR
Type
Amps
Locked Rotor Amps
13.6 A
15 A
9,000 Btu
7.3 A
780 W
n/a
13.0
14.8422
17° C-43° C (62° F~109° F)
115V/60Hz/1P
2.0 PT/H
42/36/29 dB (A)
17 lb
22 lb
10.43" x 31.1" x 7.68"
0.7 A
3
cross flow
20 W
0.7 A
EA108X1C-1FZDU1
rotary
7.46 A
40.3 A
Job: ______________________________
Location: __________________________
Engineer: __________________________
Submitted to: ______________________
Reference: _________________________
Approval: _________________________
Date: _____________________________
Submitted by: ______________________
Construction: ______________________
Unit Number: ______________________
Drawing Number: ___________________
A
B
C
FRS093LC1 Outdoor
B
A
C
FRS093LW1 Indoor
OUTDOOR UNIT
Sound Rating
Net Weight
Shipping Weight
Dimensions (H x W x D)
Recommended Fuse
Minimum Amps
Running Current
Drive Type
Motor Watts
CFM (high)
FEATURES
Controls
Remote Control
Temperature control
Timer
Air Louvers
Horizontal
Vertical
Low Voltage Restart
Self-Diagnosis
Quiet Operation
Air Filter
REFRIGERANT SYSTEM
Refrigerant
Ounces
Lineset
Maximum Height
Maximum Line length
Discharge Vapor Line (od)
Suction (od)
£
55 dB (A)
67 lb
72 lb
21.26" x 30.71" x 9.84"
15 A
0.7 A
7.3 A
asynchronous
77 W
1058
electronic
lcd wireless
17-30° C
24 hr
1 pieces
manual
swing
yes
yes
yes
washable, anti-mold
R410A
37.04
16.4 ft
26 ft
65.6 ft
F
8 mm (5/16")
F
12.7 mm (1/2")
Ductless Mini-Split System Air Conditioners
Submittal Sheet
FRS093LS1
PRODUCT DIMENSIONS
Indoor –
A - Height
B - Width
C - Depth
Max. Wall Thickness
Outdoor –
A - Height
B - Width
C - Depth
10-7/16"
31-1/8"
7-11/16"
18"
21-1/4"
30-3/4"
9-7/8"