PROBLEM
POSSIBLE CAUSE
SOLUTION
Temperature is set incor-
rectly.
Refer to "Operation" .
Water flows on the rear
plate of the refrigerator.
During the automatic de-
frosting process, frost
melts on the rear plate.
This is correct.
Water flows inside the re-
frigerator.
The water outlet is clog-
ged.
Clean the water outlet.
Food products prevent
that water flows into the
water collector.
Make sure that food products
do not touch the rear plate.
Water flows on the floor.
The melting water outlet is
not connected to the evap-
orative tray above the
compressor.
Attach the melting water out-
let to the evaporative tray.
The temperature in the ap-
pliance is too low/too high.
The temperature regulator
is not set correctly.
Set a higher/lower tempera-
ture.
The door is not closed cor-
rectly.
Refer to "Closing the door".
The food products' tem-
perature is too high.
Let the food products temper-
ature decrease to room tem-
perature before storage.
Many food products are
stored at the same time.
Store less food products at the
same time.
The thickness of the frost
is greater than 4-5 mm.
Defrost the appliance.
The door has been opened
often.
Open the door only if necessa-
ry.
There is no cold air circula-
tion in the appliance.
Make sure that there is cold
air circulation in the appliance.
If the advice does not lead to the
desired result, contact the nearest
Authorised Service Centre.
Replacing the lamp
CAUTION!
Disconnect the plug from the mains
socket.
14
TROUBLESHOOTING
Summary of Contents for FRBIFF701
Page 20: ...222372914 A 162016 ...