12
OPERATING INSTRUCTIONS
YOU WILL SEE:
DO THIS:
PRESS
ON/OFF BUTTON
TO TURN UNIT OFF:
TO CHANGE TEMPERATURE DISPLAY:
DO THIS:
PRESS AND HOLD THE UP/DOWN
BUTTONS SIMULTANEOUSLY
FOR 3 SECONDS
YOU WILL SEE:
Note: The control is capable of displaying
temperature in degrees Fahrenheit or
degrees Celsius.
If the display reads "HS", ”AS”, ”ES”, ”CS” or
”OS”, a sensor has failed. Contact your
Authorized Frigidaire Service Center.
FAULT CODES:
Now that you have mastered the operating
procedure, here are more features in your
control that you should become familiar
with.
ADDITIONAL THINGS YOU SHOULD KNOW
NOTE
The "Cool" circuit has an automatic 3
minute time delayed start if the unit is
turned off and on quickly. This prevents
overheating of the compressor and possible
circuit breaker tripping. The fan will
continue to run during this time.
•
There is a 2-Second delay for the
compressor shutting down when selecting
FAN ONLY. This is to cover the possibility
of having to roll through to select another
mode.
•
The control will maintain the set
temperature within 2 degrees Fahrenheit,
between 60°F and 90°F degrees.
•
After a power outage, the unit will
memorize the last setting and return the
unit to the same setting once power is
restored.
• The unit should be operated in a
temperature range of indoor side 60°F -
90°F (16°C - 32°C), outdoor side 64°F -
109°F (18°C - 43°C). Performance may be
reduced outside of these operating
temperatures.