background image

6

GB

Installing the hood 

  IMPORTANT

We recommend that two people carry 
out the installation. Pay attention to the 
procedure described in the assembly 
instructions.



Preparation

•  Determine the exact location of the range hood.
•  Plan the route for venting exhaust to the outdoors 

(fig.  ).

•  Plan the power connection prior to installation so 

that electrical wiring will not be visible afterwards.

• 

House  wiring  location: 

The  junction  box  is 

located on the top right side of the hood. Wiring 
should  enter  the  back  wall  at  least  20”  above 
the bottom of the installation height, and within 
3-3/8” to 4-3/4” of the right side of the centerline 
(fig.  / ). 

fig.

•  Use  the  shortest  and  straightest  duct  route 

possible.

•  The  wall  breakthrough  must  be  carried 

out  by  a  professional  prior  to  installing  the 
range  hood.  Pay  attention  to  the  length  of 
the  exhaust  hose  when  planning  the  wall 
breakthrough.  The  exhaust  hose  must  reach 
the  outer  edge  of  the  wall  without  any  kinks.   

Important! 

If the exhaust hose leads through an 

outer wall,  install a wall cap with damper or roof 
cap at the exterior opening (not delivered). This 
can be installed by the professional that performs 
the wall breakthrough.

•  Flexible metal round ducts should only be used 

when  no  other  duct  fitting  exists.  Limit  use  to 
short  lengths  and  do  not  crush  when  making 
corners.

Examples of possible ducting or air 
recirculation

Pipe

Collar

fig.

Installing range hood to the wall 
(Exhaust operation)

Install framing for hood support

•  If  drywall  is  present,  mark  the  screw  hole 

locations.

•  Cut  away  enough  drywall  to  expose  2  vertical 

studs  at  the  holes  location  indicated  by  the 
template. Install two horizontal supports at least 
1” x 6” between two wall studs at the bottom and 
top mounting holes installation location (fig.  ).

•  The  horizontal  support  must  be  flush  with  the 

room side of the studs. Use cleats behind both 
sides of the support to secure to wall studs.

•  Reinstall drywall and refinish.

•  If open fireplaces are operated in the same room, 

ask your local chimney sweeper about the local 
regulations prior to installation.

•  If you are renting, then approval must be obtained 

from the owner of the property.

•  Attention!

 In order for the range hood to reach 

optimal performance, install it over the middle of 
the cooking area.

•  The following accessories are required to mount 

the range hood (not included):

 

  Exhaust duct

 

  Power drill with 3/16” and 1/8” bits

 

  Screwdriver

 

  Level

 

  Cable detector

 

  Measuring tape

 

  Duct tape

fig.

Installation

height

8 to 9

ft

Center line

36”

Ducting installation guidelines

•  For safety reasons, ducting should vent directly 

outdoors (not into an attic, underneath the house, 
into the garage or into any enclosed space).

•  Keep duct runs as short and straight as possible.
•  Duct fittings (elbows and transitions) reduce air 

flow efficiency.

•  Back to back elbow and “S” turns give very poor 

delivery and are not recommended.

•  A short straight length of duct at the inlet of the 

remote blower gives the best delivery.

•  Transition  to  duct  from  the  integral  blower  or 

remote duct transition as close to the downdraft 
as is possible.

•  Use a suitable 6” round duct.
 

Installing the hood 

Installing the hood

00-Elux FHWC3060LSA-Range hood-Book-01.indd   6

12/8/10   12:43 PM

Summary of Contents for FHWC3060LS

Page 1: ...Use care guide Guia de uso y cuidado Guide d utilisation et d entretien 30 and 36 Range Hood 316902443 December 2010 FHWC3060LSA FHWC3660LSA ...

Page 2: ...o serve you You can register online at www frigidaire com or by dropping your Product Registration Card in the mail Questions For toll free telephone support in the U S 1 800 944 4044 or Canada 1 800 265 8352 For online support and Internet production information visit http www frigidaire com Important safety instructions Do not attempt to install or operate this appliance until you have read the ...

Page 3: ...manner intended by the manufacturer If you have questions contact the manufacturer Installation work and electrical wiring must bedonebyqualifiedperson s inaccordance with a ll applicable codes standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heat...

Page 4: ...er or the electric element Be careful to prevent burns If the flames do not go out immediately evacuate and call the fire department Never pick up a flaming pan you may be burned Do not use water including wet dishcloths or towels a violent steam explosion will result Use an extinguisher only if You know you have a class ABC extinguisher and you already know how to operate it The fire is small and...

Page 5: ...Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Power requirement 120V 60Hz 15 or 20A branch circuit Intended use Yourrangehoodisintendedforexhaustoperation only This range hood is not recommended to be used over indoor grills Do not use it to exhaust hazardous or explosive materials or vapors Parts...

Page 6: ...t delivered This can be installed by the professional that performs the wall breakthrough If open fireplaces are operated in the same room ask your local chimney sweeper about the local regulations prior to installation If you are renting then approval must be obtained from the owner of the property Attention In order for the range hood to reach optimal performance install it over the middle of th...

Page 7: ...izontal supports at least 1 x 6 between two wall studs at the bottom and top mounting holes installation location fig The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure to wall studs Reinstall drywall and refinish l d h f t y r r e r t fig IMPORTANT Framing must be capable of supporting 100 lbs Step 1 Make sure that no cables ...

Page 8: ...rews depending on the wall type Wall type Required screws Wood 4 wood screws 14 Brick Concrete 4 long screws 10 Insert 2 screws 10 or 14 in the top location but do not fully insert the screws fig Mount the range hood 1 to the wall and tighten the screws Insert and tighten the 2 remaining screws on the bottom location of the range hood fig Attach the collar 6 to the range hood 1 Secure with 2 short...

Page 9: ...Connect the incoming positive neutral and ground cables to the respective terminals The ground cable is already pre assembled onto the junction box to provide grounding fig fig L live Black ground Green N neutral White L N Mount the junction box onto the range hood using 2 short screws 15 fig fig Step 6 Insert the upper chimney 3 into the lower chimney 3 from top to bottom fig Mount upper and lowe...

Page 10: ... burning gas or other fuels not applicable to appliances that only discharge the air back into the room The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room Air recirculation operation Recirculated air Kitchen fumes are removed and after purification are fe...

Page 11: ...oke and dust so the filter is directly affecting the efficiency of the range hood If not cleaned the grease residue potential flammable will saturate on the filter Clean it with household cleaning detergent The filter is dishwasher safe Recirculator clean the ventilation openings on the top sides every 4 6 months Charcoal filters If the model is not vented to the outside the air will be recirculat...

Page 12: ...n but fan does not work The fan blade is jammed The motor is damaged Both light and fan do not work Light bulb broken Replace with a bulb with correct rating Problem with electrical connection Check the electrical connection with an electrician Suction performance is not good Distance between the appliance and the cooking place too large Readjust the distance page 7 fig and table below Metallic an...

Page 13: ...rsons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God Warranty information USA 1 800 944 9044 Electrolux Major Appliances North America 10200 David Taylor Drive Charlotte NC 28262 Canada 1 800 265 8352 Electrolux Canada Corp 5855 Terry Fox Way Mississauga Ontario Canada L5V 3E4 DISCLAIMER OF IMPLIED WARRANTIES L...

Reviews: