background image

Specifications  

subject to change.

Accessories information available  

on the web at 

frigidaire.com

Microwaves

FGMV175Q F/ W / B     

30" Over-The-Range

Ducted Option Specifications

• 

For outside ventilation.

• 

Exhaust duct adapter will be needed for outside ventilation, to mate 

with standard 3-1/4" x 10" rectangular duct. If round duct required, 

rectangular-to-round transition adapter will be needed with no less 

than 6" diameter.

• 

For most efficient airflow exhaust, use a straight run or as few elbows 

as possible with a maximum duct length of 3-1/4" x 10" rectangular or 

6" diameter round duct, not to exceed 140 equivalent feet.

• 

For horizontal installation, be sure to allow enough space between 

wall studs to accommodate exhaust.

• 

Refer to installation instructions on web for detailed duct  

preparation and converting exhaust vent blower system for exterior 

exhaust ventilation.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Optional Accessories

• 

36" Stainless Steel Filler Panel Kit – (PN # MWFILKTSS).

• 

36" Stainless Steel Filler Panel Kit – (PN # MWFILKTBK).

• 

36" Stainless Steel Filler Panel Kit – (PN # MWFILKTWH).

Microwave Specifications

• 

Product Shipping Weight (approx.) – 63 Lbs.

• 

Voltage Rating – 120V / 60 Hz / 15 Amps

• 

Connected Load (kW Rating) @ 120 Volts = 1.6 kW  

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

• 

Amps @ 120 Volts = 14.2 Amps

• 

Always consult local and national electric codes.

• 

Grounded outlet should be located in cabinet above, with hole in base 

to route power cord. Carefully follow top template instructions for 

power cord clearance when installing beneath smooth, flat cabinets.

• 

Microwave’s exhaust ventilation system is preset to recirculate air 

inside with no ducting system required. Exhausting air outside is 

optional, using either vertical or horizontal ducting system. 

(Refer to 

Ducted Option Specifications for outside ventilation.)

• 

For safe and proper installation, microwave MUST be mounted to 

BOTH a top cabinet AND a wall, and connected to at least one wall 

stud. Can NOT be installed in island or peninsula cabinet arrangements.

• 

Cabinet bottom MUST be level to insure proper installation.

• 

Cabinet MUST be capable of supporting a total load of 110 lbs.

• 

Filler blocks recommended for installation when cabinet front hangs 

below recessed bottom shelf.

• 

Minimum distance of 30" required from cooking surface to bottom 

edge of top cabinet.

• 

Minimum distance of 66" required from floor to top of microwave.

• 

Opening between cabinets MUST be 30" wide and free of obstructions. 

For openings up to 36" wide, order optional 36" Filler Panel Kit to fill  

in gap between unit and cabinets.

• 

Allow 26" minimum clearance for 90° door swing.

30" Over-the-Range Microwave Ovens

with Side Controls (FGMV175Q)

Gallery (1.7 Cu. Ft.)

USA

 • 

10200 David Taylor Drive

 • 

Charlotte, NC 28262

 • 

1-800-FRIGIDAIRE

 • 

frigidaire.com

CANADA

 

 5855 Terry Fox Way 

 Mississauga, ON L5V 3E4 

 1-800-265-8352 

 

frigidaire.ca

FGMV175Q 02/14 

© 2014 Electrolux Home Products, Inc.

Summary of Contents for FGMV175Q

Page 1: ...oof Stainless Steel1 Resists fingerprints and smudges so it s easy to clean Available in 1 Select models only Over 30 Options Versatile settings include Chicken nuggets and snacks Effortless Reheat Reheat almost anything with the touch of a button SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once Sensor Cooking Microwave automatically adjusts power levels ...

Page 2: ...ly Connection Location Voltage Rating Connected Load kW Rating 120 Volts1 Minimum Circuit Required Amps Shipping Weight Approx 1 For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation Express Select Smudge Proof Stainless Steel F Color Coord W B Stainless Steel F Color Coord W B 1 7 1 000 Yes White 13 Yes Y...

Page 3: ...ust be grounded for safe operation Amps 120 Volts 14 2 Amps Always consult local and national electric codes Grounded outlet should be located in cabinet above with hole in base to route power cord Carefully follow top template instructions for power cord clearance when installing beneath smooth flat cabinets Microwave s exhaust ventilation system is preset to recirculate air inside with no ductin...

Page 4: ...TGDLNS_SSR FR 04 13 2013 Electrolux Home Products Inc General Installation Guidelines with Side by Side Refrigerator Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Specifications subject to change ...

Page 5: ...4 1 800 265 8352 frigidaire ca INSTGDLNS_TMR FR 04 13 2013 Electrolux Home Products Inc Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Guidelines with Top Mount Refrigerator ...

Page 6: ... 1 800 265 8352 frigidaire ca INSTGDLNS_FDR FR 04 13 2013 Electrolux Home Products Inc Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front General Installation Guidelines with French Door Refrigerator ...

Page 7: ...00 265 8352 frigidaire ca INSTGDLNS_ARAF FR 04 13 2013 Electrolux Home Products Inc Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Guidelines with All Refrigerator or All Freezer ...

Reviews: