Accessories information available
on the web at
frigidaire.com
Slide-In Ranges
FGGS3065K F/ W/ B
30" Gas
30" Gas Slide-In Range
Gallery
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
FGGS3065K 10/13
© 2013 Electrolux Home Products, Inc.
Specifications
subject to change.
Slide-In Range Specifications
•
Product Shipping Weight (approx.) – 250 Lbs.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.2 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120V = 10 Amps
•
Always consult local and national electric and gas codes.
•
Make sure wall coverings around range can withstand heat generated
by range.
•
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
•
Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
•
Range ships with 3/4" factory regulator.
•
LP Gas Conversion Kit supplied.
•
Gas supply piping can be through back wall or floor. Optimum
location is between 1" and 8" from floor through back wall within
3" of center line; can also be through floor against back wall within
12" of center line. Supply line must be equipped with approved
manual shutoff valve, accessibly located in same room as range.
•
Countertop MUST be level in all directions and adjustable range
height at least 1/16" greater than tallest cabinet height, to ensure
metal rangetop flange will fit properly on countertop edge.
•
When installing optional Backguard Kit, cutout depth of 21-3/4"
minimum / 22-1/8" maximum needs increased to 24".
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
•
Allow 24" minimum clearance between rangetop and bottom of cabinet
when bottom of wood or metal cabinet is protected by not less than
1/4" flame-retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
Allow 30" minimum clearance when cabinet is unprotected.
•
Allow 5" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.
•
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
Countertop Preparation
Rangetop’s side flanges overlap countertop cutout edges – for detailed
preparation instructions, refer to product installation guide on the web.
•
Flat Square-Finish Countertops –
require no preparation since
rangetop’s flange lays directly on countertop edge.
•
Formed Front-Edged Countertops –
require front molded edge to
be shaved flat 3/4" from each front corner of opening.
•
Tile Countertops –
may need trim cut back 3/4" from each front
corner of opening and /or rounded edge flattened.
•
For existing cutout width greater than 30-1/16" reduce the 3/4"
overlap dimension; for cutout width of 29", replace actual side
trim panels with smaller side trim panels, available with optional
Side Trim Kit
(refer to detailed kit installation instructions).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
Rear Filler Kit: White – (PN # 901193-9011),
Black – (PN # 901193-9010).
•
Side Panel Kit: White – (PN # 903074-9011),
Black – (PN # 903074-9010).
•
Backguard Kit: White – (PN # 903046-9011),
Black – (PN # 903046-9010).
•
Side Trim Kit: White – (PN # 903075-9011),
Black – (PN # 903075-9010).