Specifications
subject to change.
USA
•
10200 David Taylor Drive
•
Charlotte, NC 28262
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
FGGF3032M 10/11
© 2011 Electrolux Home Products, Inc.
Freestanding Ranges
FGGF3032M F/ W/ B
30" Gas
30" Gas Freestanding Ranges
Gallery
Freestanding Range Specifications
•
Product Shipping Weight (approx.) – 215 Lbs.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.8 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 15 Amps
•
Always consult local and national electric and gas codes.
•
Make sure wall coverings around range can withstand heat generated
by range.
•
Linoleum or any other synthetic floor covering located beneath range,
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
•
Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
•
Do not install range beneath any downward-blowing, overhead vent
hood or air curtain.
•
Range ships with 3/4" factory regulator.
•
Range is LP Gas convertible.
(Optional LP Gas Conversion
Kit available.)
•
Floor beneath range MUST be solid and level.
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
•
Range can be installed flush to wall with 0" minimum rear clearance.
•
Minimum clearance required
(from edge of rangetop to nearest
combustible wall on either side of range above 36" height)
is based
on largest burner output rating on cooking surface.
•
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
•
Follow all dimension requirements provided to prevent property
damage, potential fire hazard, and incorrect countertop and
cabinet cuts.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
LP Gas Conversion Kit – (PN # GRLP3)