Frigidaire 27" Combination Installation –

24" Built-In Microwave (with 27" Trim Kit)

Electric Single Wall Oven (excluding model GLEB27Z7H)

Warmer Drawer

27" Combination Installation

Built-In Microwave / Single Wall Oven / Warmer Drawer

27" Combination Installation Specifications

 Always consult local and national electric codes.  

(Refer to product-specific electrical specifications on this page.)

 Minimum 23-5/8" deep cutout dimension is critical for proper 

combination installation, to ensure that each built-in product’s 

faceplate will fit flush against cabinet front.

 Bases must be level and cabinet front must be square.

 Minimum 4-1/2" required distance from bottom of Warmer Drawer 

cutout to floor.

 Respect critical dimensions as noted for proper installation of  

built-In products.

 Minimum 21" clearance needed for Wall Oven door depth when open.

27" Built-In Microwave Specifications

 For built-in installation, microwave MUST be installed with optional 

27" Trim Kit which includes Bottom Duct Assembly – shipped in 

separate box, ordered by individual part number. 

 Voltage Rating – 120V / 60 Hz / 15 or 20 Amps

 Connected Load (kW Rating) @ 120 Volts = 1.7 kW  

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

 Amps @ 120 Volts = 14.3 Amps

 Full oven base of solid plywood or similar material required, capable 

of supporting 100 Lbs.

 Minimum 2-7/8" clearance required from bottom of Built-In Microwave 

cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap 

between both product faceplates.  

27" Electric Single Wall Oven Specifications

 Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz 

AC only electrical supply with ground required on separate circuit 

fused on both sides of line.

 For detailed electrical requirements, refer to model-specific product 

page and installation guide on web.

 To support Wall Oven when using in combination with Warmer 

Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base, 

capable of supporting 200 Lbs. Do NOT use full base, since planks  

are necessary to allow for proper air displacement.

27" Warmer Drawer Specifications

• Voltage Rating – 120V / 450W / 60 Hz / 15 Amps
• Connected Load (kW Rating) @ 120 Volts = 0.5 kW 

 

(For use on adequately wired 120V, dedicated circuit having 2-wire 

service with a separate ground wire. Appliance must be grounded  

for safe operation.)

• Amps @ 120V = 3.8 Amps
• Full base of solid plywood or similar material required, capable of 

supporting 100 Lbs. 

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Summary of Contents for FGEW2765KB - Gallery 27" Convection Single Oven

Page 1: ...ded power means you can broil food more evenly One Touch Self Clean Start the self cleaning cycle with just the touch of a button A D A Compliant3 Sabbath Mode Star K Certified Available in 1 Based on single rack cooking performance not set temperature using Quick Preheat 2 Select models only 3 When properly installed meets the appliance standards in the Americans with Disabilities Act and the Arc...

Page 2: ...lf Clean Yes Variable 400 500 F Effortless Yes Yes Yes Quick Yes Yes Yes Yes Yes Yes Quick 2 3 4 Hours Yes Yes Yes Yes Yes 3 5 True Convection 2 Yes 1 Heavy Duty 1 SpaceWise Half Rack 1 Offset Rack Even Baking Technology Power Broil 1 450 3 400 Yes Yes 16 1 2 x 20 1 2 x 18 1 32 Left Bottom Rear 240V 208V 60Hz 4 1 3 1 17 1 14 9 20 Yes 155 Lbs 1 When properly installed meets the appliance standards ...

Page 3: ...lush against cabinet front To adapt oven to fit cutout height greater than 28 1 8 add one 2 wide wood shim of appropriate height to each side of opening under oven side rails Lifting oven will hide larger cutout opening at top and oven s 1 high bottom trim will hide shims at bottom Standard 1 High Bottom Trim included Full oven base of solid plywood or similar material required capable of supporti...

Page 4: ...lectric Single Wall Oven Specifications All Frigidaire Electric Single Wall Ovens are approved to be used beneath any approved Frigidaire Gas Cooktop This installation page excludes approved wall oven model GLEB27Z7H For model specific installation details refer to Gas Cooktop Installation Over 27 Electric Single Wall Oven GLEB27Z7H Specifications pages on web For detailed Gas Cooktop installation...

Page 5: ...ommodate the depth of approved electric cooktop models To route armored cable to junction box cut minimum 4 x 4 opening in right side filler panel Allow 4 1 2 maximum height from oven base to floor if cooktop is installed directly over wall oven Note For planning purposes only Refer to Product Installation Guide on the web at frigidaire com for detailed instructions excludes side swing wall oven C...

Page 6: ...ed Load kW Rating 120 Volts 1 7 kW For use on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation Amps 120 Volts 14 3 Amps Full oven base of solid plywood or similar material required capable of supporting 100 Lbs Minimum 2 7 8 clearance required from bottom of Built In Microwave cutout to top edge of Wall Oven s f...

Page 7: ... on adequately wired 120V dedicated circuit having 2 wire service with a separate ground wire Appliance must be grounded for safe operation Amps 120 Volts 14 3 Amps Full oven base of solid plywood or similar material required capable of supporting 100 Lbs Minimum 2 7 8 clearance required from bottom of Built In Microwave cutout to top edge of Wall Oven s faceplate leaving a 2 visible gap between b...

Page 8: ...8352 frigidaire ca INSTGDLNS_SSR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A General Installation Guidelines with Side by Side Refrigerator Top Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front ...

Page 9: ...5 8352 frigidaire ca INSTGDLNS_TMR FR 10 10 2010 Electrolux Home Products Inc Printed in the U S A Use these dimensions and clearance instructions for planning purposes only For detailed installation instructions refer to installation guide packed with product or on the web at frigidaire com Front Top Front Top General Installation Guidelines with Top Mount Refrigerator ...