4
ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
(with side-by-side and cooktop combination specialty installations)
In cold weather shipping and storage
FRQGLWLRQVPDNHVXUHWKDWRYHQLVLQ¿QDOORFDWLRQ
at least three (3) hours before switching on power.
Switching on power while oven is still cold may
damage the oven controls.
4. Electrical connection
It is the responsibility and obligation of the consumer to
FRQWDFWDTXDOL¿HGLQVWDOOHUWRDVVXUHWKDWWKHHOHFWULFDO
installation is adequate and is in conformance
with the National Electrical Code ANSI/NFPA No.
70-latest edition, or with CSA Standard C22.1,
Canadian Electrical Code, Part 1, and local codes and
ordinances.
Risk of electrical shock (Failure to
heed this warning may result in electrocution or
RWKHUVHULRXVLQMXU\7KLVDSSOLDQFHLVHTXLSSHGZLWK
copper lead wire. If connection is made to aluminum
house wiring, use only connectors that are approved
IRUMRLQLQJFRSSHUDQGDOXPLQXPZLUHLQDFFRUGDQFH
with the National Electrical Code and local code and
ordinances. When installing connectors having screws
which bear directly on the steel and/or aluminum
ÀH[LEOHFRQGXLWGRQRWLJKWHQVFUHZVVXႈFLHQWO\WR
GDPDJHWKHÀH[LEOHFRQGXLW'RQRWRYHUEHQGRU
H[FHVVLYHO\GLVWRUWÀH[LEOHFRQGXLWWRDYRLGVHSDUDWLRQ
of convolutions en exposure of internal wires.
DO NOT ground to a gas supply pipe. DO NOT
connect to electrical power supply until appliance
is permanently grounded. Connect the ground wire
before turning on the power.
(If your appliance is equipped with a
white neutral conductor.)
This appliance is manufactured with a white neutral
power supply and a frame connected copper wire. The
frame is grounded by connection of grounding lead to
neutral lead at the termination of the conduit, if used in
USA, in a new branch circuit installation (1996 NEC),
mobile home, recreational vehicles, where local code
do not permit grounding trough the neutral (white) wire
or in Canada, disconnect the white and green lead
from each other and use ground lead to ground unit in
accordance with local codes, connect neutral lead to
branch circuit-neutral conductor in usual manner see
Figure 4. If your appliance is to be connected to a 3
ZLUHJURXQGHGMXQFWLRQER[86RQO\ZKHUHORFDOFRGH
permit connecting the appliance-grounding conductor
to the neutral (white) see Figure 3.
NOTE TO ELECTRICIAN: The armored cable leads
VXSSOLHGZLWKWKHDSSOLDQFHDUH8/UHFRJQL]HGIRU
connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring.
The current carrying capacity of the conductor is
governed by the temperature rating of the insulation
around the wire, rather than the wire gauge alone.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire (US
2QO\VHH¿JXUH
1. Disconnect the power supply.
,QWKHMXQFWLRQER[
connect appliance and power supply cable wires as
shown in Figure 3.
(OHFWULFD]DUG
• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
'LVFRQQHFWSRZHUWRWKHMXQFWLRQER[EHIRUH
making the electrical connection.
• This appliance must be connected to a grounded,
metallic, permanent wiring system, or a grounding
connector should be connected to the grounding
terminal or wire lead on the appliance.
• Do not use a gas supply line for grounding the
appliance.
)DLOXUHWRGRDQ\RIWKHDERYHFRXOGUHVXOWLQD¿UH
SHUVRQDOLQMXU\RUHOHFWULFDOVKRFN
Figure 3
3-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Black
Wires
Junction
Box
Cable from appliance
Ground Wire
(Bare or Green Wire)
White Wire
(Neutral)
U.L.-Listed Conduit
Connector (or CSA listed)
Red
Wires
White Wire
(Neutral)