Electric Cooktop Installation  

Over 30"/27" Electric Single Wall Oven

Combination Frigidaire Electric Cooktop/

27" & 30" Electric Wall Oven Under-Counter Installation

FRIGIDAIRE

USA

 

 

Electrolux Major Appliances, North America

 

 250 Bobby Jones Expressway 

 Martinez, GA 30907 

 1-8

00

-FRIGIDAIRE 

 

frigidaire.com

 

CANADA

 

 

Electrolux Canada Corporation

 

 5855 Terry Fox Way 

 Mississauga, ON L5V 3E4 

 1-800-265-8352 

 

frigidaire.ca

EC_EW INST FR 04/09 

© 2009 Electrolux Home Products, Inc. 

Printed in the U.S.A.

Specifications  

subject to change.

30"/ 27" Electric Single Wall Oven  

Under-Counter Installation Specifications

 Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz 

AC only electrical supply with ground required on separate circuit 

fused on both sides of line.

 For detailed electrical requirements, refer to model-specific product 

page and installation guide on web.

 Always consult local and national electric codes. 

 Minimum 21" clearance for oven door depth when open.

 Minimum 23-1/2" deep cutout dimension is critical for proper 

installation, to ensure that oven’s faceplate will fit flush against 

cabinet front.

 Full oven base of solid plywood or similar material required,  

capable of supporting 200 Lbs. Install over two runners and flush 

with toe plate.

 Base must be level and cabinet front must be square.

 Allow 5" maximum height from oven base to floor, if NO cooktop is 

installed directly over wall oven.

Electric Cooktop Installation Over  

30"/ 27" Electric Single Wall Oven Specifications

All Frigidaire® Electric Single Wall Ovens are approved to be used 

beneath any approved Frigidaire® Electric Cooktop.
For detailed Electric Cooktop installation, refer to model-specific 

product page and installation guide on web.

 Side filler panels necessary to isolate oven from adjoining cabinets. 

Panel height may need to be modified to accommodate the depth  

of approved electric cooktop models.

 To route armored cable to junction box, cut minimum 4" x 4" opening 

in right cabinet side panel.

 Allow 4-1/2" maximum height from oven base to floor, if cooktop is 

installed directly over wall oven.

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.