1
30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY
A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
G.
Minimum cutout depth is increased to 24" (61 cm) with backguard.
30" Min.
(76.2 cm) Min.
18" Min.
(45.7 cm) Min.
30" Min.
**
(76.2 cm) Min.
**
24" Min.
(61 cm) Min.
Approx. 1 7/8"
(4.8 cm)
G
H
F
Grounded Junction Box or Wall
Outlet Should Be Located 8" to
17" (20.3 - 43.2 cm) From Right
Cabinet and 2" to 4" (5.1-10.2
cm) From Floor
Shave Raised Edge
To Clear 30" (76.2
cm) Wide Cooktop
Rim.
1 ½" Max.
(3.8 cm Max.)
1 1/8"
(45.7 cm)
22 7/8"
(58.1 cm)
FRONT
OF
CABINET
P/N 318201600 (0201) Rev. C
English – pages 1-9
Español – páginas 10-18
Français – pages 19-27
Locate Cabinet Doors 1"
(2.5 cm) Min. From Cutout
Opening
* Note
: 29" (73.7 cm)
Wide Opening For
Overlapping Cooktop and
Built-In Look.
If Installing Models With
Optional Side Panels,
Cutout Area Including
Countertop Must Be At
Least 30" (76.2 cm) Wide.
30"
(76.2 cm)
Exact
C
B
A
23 ½"
(59.7 cm)
•
Door Open
(see note)
Do not pinch the power supply
cord between the range and
the wall.
Do not seal the range to the
side cabinets.
** NOTE:
24" (61 cm)
minimum clearance
between the cooktop and
the bottom of the cabinet
when the bottom of wood
or metal cabinet is
protected by not less than
1/4" (0.64 cm) flame
retardant millboard covered
with not less than No. 28
MSG sheet metal, 0.015"
(0.4 mm) stainless steel,
0.024" (0.6 mm)
aluminum, or 0.020" (0.5
mm) copper.
30" (76.2 cm) minimum
clearance when the cabinet
is unprotected.
•
NOTE:
Allow at least
19 ¼" (48.9 cm) clearance
for door depth when it is
open.
1 ½"
(3.8 cm)
G
Ref.
13"
(33 cm)
A.
HEIGHT
B.
WIDTH
C.
DEPTH TO
FRONT OF
RANGE
F.
MINIMUM
CUTOUT
WIDTH
G.
CUTOUT
DEPTH
H.
HEIGHT
OF
COUNTERTOP
35 3/8" (90 cm) - 36 3/8" (92 cm)
30" (76.2 cm)
26 1/4" (66.7 cm)
29" (73.7 cm)
21 3/4" (55.2 cm)
36" (91.4 cm) standard
35 3/8" (90 cm) min.