Although vertical orientation of the exhaust system is
acceptable, certain extenuating circumstances could affect the perfor-
mance of the dryer:

Only the rigid metal duct work should be used.

Venting vertical through a roof may expose the exhaust
system to down drafts causing an increase in vent
restriction.

Running the exhaust system through an uninsulated
area may cause condensation and faster accumulation
of lint.

Compression or crimping of the exhaust system will
cause an increase in vent restriction.

The exhaust system should be inspected and cleaned a minimum of 

every

18 months 

with normal usage.  The more the dryer is used, the more

often you should check the exhaust system and vent hood for proper
operation.

EXHAUST DIRECTION

All dryers shipped from the factory are set up for rear exhausting.
However, on electric dryers, exhausting can be to the right or left side of
the cabinet or the bottom of the dryer. On gas dryers, exhausting can be
to the right side of the cabinet or the bottom of the dryer. Directional
exhausting can be accomplished by installing Exhaust Kit, P/N 131456800,
available through your parts distributor. Follow the instructions supplied
with the kit.

EXHAUST DUCT LOCATING DIMENSIONS

GAS SUPPLY REQUIREMENTS

Replace copper connecting pipe that is not plastic-

coated. Stainless steel or plastic-coated brass MUST be used.

1. Installation 

MUST

 conform with local codes, or in the absence of

local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest
edition).

2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect your

dryer to the gas supply line. The tubing 

MUST

 be constructed of

stainless steel or plastic-coated brass.

4. The gas supply line 

MUST 

have an individual shutoff valve.

5. A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for test gauge

connection, 

MUST

 be installed immediately upstream of the gas

supply connection to the dryer.

6. The dryer 

MUST

 be disconnected from the gas supply piping system

during any pressure testing of the gas supply piping system at test
pressures in excess of 1/2 psig (3.45 kPa).

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

4 3/8"

4 3/8"

4 3/8"

4 3/8"

4 3/8"

5 7/8"

5 7/8"

5 7/8"

5 7/8"

5 7/8"

13 1/2"

13 1/2"

13 1/2"

13 1/2"

13 1/2"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

7. The dryer 

MUST

 be isolated from the gas supply piping system during

any pressure testing of the gas supply piping system at test pressures
equal to or less than
1/2 psig (3.45 kPa).

                    LOCATION OF YOUR DRYER

DO NOT INSTALL YOUR DRYER:

1. In an area exposed to dripping water or outside weather conditions.
2. In an area where it will come in contact with curtains, drapes, or

anything that will obstruct the flow of combustion and ventilation air.

3. On carpet. Floor 

MUST

 be solid with a maximum slope of 1 inch (2.54

cm).

INSTALLATION IN RECESS OR CLOSET

1. A dryer installed in a bedroom, bathroom, recess or closet, 

MUST

 be

exhausted outdoors.

2. No other fuel burning appliance shall be installed in the same closet as

the Gas dryer.

3. Your dryer needs the space around it for proper ventilation.

DO NOT install your dryer in a closet with a solid door.

4. A minimum of 120 square inches (774.2 square cm) of opening, equally

divided at the top and bottom of the door, is required. Air openings
are required to be unobstructed when a door is installed. A louvered
door with equivalent air openings for the full length of the door is
acceptable.

MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES     REAR

      TOP

  FRONT

Alcove

0 (0 cm)   0 (0 cm)  15 (38.1 cm)

Closet

0 (0 cm)    0 (0 cm)   15 (38.1 cm)  1 (2.54 cm)

Closet door ventilation required:  2 louvered openings each 60 square
inches (387 square centimeters) — 3 inches (7.6 cm) from bottom and top
of door.

NOTE:

Under counter and stack models - 0 inches (0 cm)
for sides, rear, and top.

This dryer MUST be exhausted outdoors.

5. The following illustrations show minimum clearance dimensions for

proper operation in a recess or closet installation.

In installations where the exhaust system is not described in the charts, the
following method must be used to
determine if the exhaust system is acceptable:
1.

Connect an inclined or digital manometer between the
dryer and the point the exhaust connects to the dryer.

2.

Set the dryer timer and temperature to air fluff (cool
down) and start the dryer.

3.

Read the measurement on the manometer.

4.

The system back pressure 

MUST NOT

 be higher than

0.75 inches of water column.  If the system back
pressure is less than 0.75 inches of water column, the
system is acceptable.  If the manometer reading is
higher than 0.75 inches of water column, the system is
too restrictive and the installation is unacceptable.

INSTALL MALE FITTINGS IN CORRECT DIRECTION

CORRECT

INCORRECT

CLOSET DOOR

60 sq. inches
(387.1 sq. cm)

60 sq. inches
(387.1 sq. cm)

1" (2.54 cm)

0" (0  cm)

0" (0 cm)

0" (0 cm)

0" (0  cm)

1" (2.54 cm)

15" (38.1 cm)

0" (0 cm)

Summary of Contents for FEQ1442ES - 27" Electric Dryer

Page 1: ...nstallation Requirements 2 Electrical Requirements 2 Exhaust System Requirements 2 3 Gas Supply Requirements 3 Location of Your Dryer 3 Rough In Dimensions 4 Mobile Home Installation 5 Unpacking 5 Reversing Door Swing 5 6 Electrical Installation 7 Grounding Requirements 7 Electrical Connections 3 wire 7 Electrical Connections 4 wire 7 Gas Connection 8 General Installation 8 Replacement Parts 8 Req...

Page 2: ...yer MUST employ a 4 conductor power supply cord NEMA 14 30 type SRDT or ST as required rated at 240 volt AC minimum 30 amp with 4 open end spade lug connectors with upturned ends or closed loop connectors and marked for use with clothes dryers See ELECTRICAL CONNECTIONS for additional instructions OUTLET RECEPTACLE NEMA 10 30R 3 wire receptacle or NEMA 14 30R 4 wire receptacle to be located so the...

Page 3: ...3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 3 3 4 7 The dryer MUST be isolated from the gas supply piping system during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa LOCATION OF YOUR DRYER DO NOT INSTALL YOUR DRYER 1 In an area exposed to dripping water or outside weather conditions 2 In an area where it will come in contact with curtains dr...

Page 4: ...t 13 5 27 25 to front of cabinet 27 75 to clear knobs 28 5 to clear door handle 5 875 To base exhaust 5 0 4 375 To side exhausts To rear base exhausts 2 25 2 375 Gas supply pipe on rear of unit Electrical supply on rear of unit 123 19cm 72 39cm 12 7cm 11 12cm 14 93cm 69 22cm 70 49cm 72 39cm 5 72cm 6 03cm 68 58cm 34 29cm 36 91 44cm Dryer Installation Dimensions Free Standing Under Counter Stacked D...

Page 5: ... 2 and 3 for other important venting requirements 6 Installation MUST conform to current Manufactured Home Construction Safety Standard which is a Federal Regulation Title 24 CFR Part 32 80 or when such standard is not applicable with American National Standard for Mobile Homes The dryer is designed under ANSI Z 21 5 1 or ANSI UL2158 CAN CSA C22 2 latest editions for HOME USE only FOAM SHIPPING PA...

Page 6: ...remove the plugs Be careful to avoid scratching the paint 5 Remove the two handle screws and remove the handle by pulling straight out from door 6 Install the plugs from Step 3 into the holes left by removing the handle screws in Step 4 7 Lay the door on a flat surface and support the edges of the door to keep it from turning Apply moderate downward pressure on the lens with both hands and rotate ...

Page 7: ... connection of the equipment grounding conductor can result in a risk of electrical shock Check with a licensed electrician if you are in doubt as to whether the appliance is properly grounded For a grounded cord connected dryer 1 The dryer MUST be grounded In the event of a malfunction or breakdown grounding will reduce the risk of electrical shock by a path of least resistance for electrical cur...

Page 8: ... instructions in this manual and all other literature included with this dryer are not meant to cover every possible condition and situation that may occur Good safe practice and caution MUST be applied when installing operating and maintaining any appliance VALVE OPEN GAS FLOW POSITION GAS CONNECTION 1 Remove the shipping cap from gas pipe at the rear of the dryer NOTE DO NOT connect the dryer to...

Page 9: ...stros que giren hacia afuera que se abren cuando la secadora se encuentra en funcionamiento Cuando la secadora se detiene los registros se cierran automáticamente para evitar las corrientes de aire y la entrada de insectos y roedores Para evitar obstruir la salida mantenga una altura libre mínima de 12 30 5 cm entre la caperuza de salida y el piso o entre cualquier otra obstrucción Lossiguientesre...

Page 10: ...a de exhaustación y de la tapa del orificio de ventilación UBICACIÓN DEL ESCAPE Todas las secadoras vienen de fábrica equipadas con escape trasero Sin embargo en las secadoras eléctricas el escape puede hacerse al lado derecho o izquierdo del gabinete o en la parte inferior de la secadora En las secadoras a gas el escape del aire puede estar en el lado derecho del gabinete o en la parte inferior d...

Page 11: ...ulgada 0 cm para los lados parte trasera y en la parte superior El tubo del escape de la secadora debe ser instalado hacia el exterior 5 Las siguientes ilustraciónes muestran las dimensiónes mínimas de espacio libre que debe existir para el buen funcionamiento de la secadora cuando se instala en un nicho o en un armario 7 La secadora DEBE aislarse del sistema de tuberías de alimentación de gas dur...

Page 12: ...a parte posterior de la unidad Pipe de la fuente de gas en la parte posterior de la unidad Línea altura de centro para el respiradero posterior derecho izquierdo Para basar los extractores A los extractores de la parte posterior y de la base Al frente del gabinete 69 22cm A las perillas claras 70 49cm A la manija clara de la puerta 72 39cm Dimensiones Apiladas De la Instalación Del Secadora Al fre...

Page 13: ...bstrucciones Es preferible usar ducto de metal que sea rígido 2 Si el tubo de escape de la secadora corre a través del piso y el área debajo de la casa móvil es cerrada el ducto de escape DEBE terminar fuera del recinto con el extremo final asegurado en contra de la estructura de la casa móvil 3 Al instalar una secadora de gas en una casa móvil hay que instalar una provisión de aire fresco supleme...

Page 14: ...tar un cuchillo plástico ayudar a quitar los tapóns Tenga cuidado de evitar de rasguñar el pintura 5 Remove los dos tornillos de la manija y quitar la manija tirando recto hacia fuera de door 6 Install los tapóns del paso 3 en los agujeros a la izquierda quitando la manija atornillan en el paso 4 7 Lay la puerta en una superficie plana y apoyan los bordes de la puerta para guardarla de dar vuelta ...

Page 15: ...uministro de energía de 240 voltios INSTALACIÓN ELÉCTRICA SecadorasELÉCTRICAS Los siguientes requerimientos son específicos para el funcionamiento correcto y seguro de su secadora El incumplimiento de estas instrucciones puede causar prolongación excesiva del tiempo de secado y riesgos de incendio La conexión indebida del conductor de puesta a tierra del equipo puede ocasionar un riesgo de choque ...

Page 16: ...ficados por el fabricante podía dar lugar a daños corporales a daños materiales o a daño a la lavadora Si necesita obtener piezas de recambio para su secadora póngase en contacto con el distribuidor donde compró su secadora llame 1 800 944 9044 o visitan nuestros website www frigidaire com para la Distribuidor Autorizada Company de las Piezas de Frigidaire más cercana usted Cuando se reparan los c...

Reviews: