1
30" ELECTRIC DROP-IN RANGE INSTALLATION INSTRUCTIONS
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
P/N 318201613 (0510) Rev. C
English - pages 1-6
Español - páginas 7-12
Printed in United States
A. Cutout Width
B. Cutout Depth
C. Height of
(Countertop and
(According to front
Cutout
cabinet)
of cabinet)
30 ±
1/16
"
(76,2 ± 0,15 cm)
29" (73,7 cm)
21 3/4" (55,2 cm) min
22 1/8" (56,2 cm) max
IMPORTANT:
Cabinet and countertop width
should match the cutout width.
E
E
A
A
A
C
B
1/2” min.
1/2” min.
1/4” min.
Grounded Junction Box in
adjoining Cabinet
24" Min.
(61 cm Min.)
18" Min.
(45,7 cm Min.)
30" Min.
(76,2 cm Min.)
See Note 3
30"
(76.2 cm)
Locate Cabinet Doors
1" (2,5 cm) Min.
from Cutout Opening
Shave Raised Edge to
Clear Space for a
31½" (81 cm) Wide
Cooktop Rim.
1½" Max.
(3,8 cm) Max
.
31½"
(81 cm)
Exact
App. 1-7/8"
(4,8 cm)
These surfaces should be flat &
leveled (hatched area).
Smoothtop Models
NOTE:
Two sets of holes are provided
under anti-tip bracket. Bracket is
attached in the upper hole position at
the factory. Refer also to page 5, item 9
for additional details.
48" (122 cm)
Armored Cable
ANTI-TIP BRACKET
AT REAR OF RANGE
For existing 29" (73,7 cm) cutout wide opening, you
must call the Service Center for optional thinner side
panels. Also you must prepare the countertop edge as