6
Bucket
The bucket is mounted to the front of the chassis and is
located beneath the cooling coil to catch the condensate.
A float mounted on the bucket is used to activate a switch
to shut off the unit when the bucket is full of water.
If the unit is to be installed near a floor drain, a permanent
drain hose may be attached to the threaded hose
connection on the bucket. If you want water to flow directly
into the drain, place the hose connection of the bucket
directly over the drain. When using either method of
draining, a plastic membrane in the hose connection of
the bucket must be cut out in order to permit the water to
flow into the hose or drain. To return to bucket collection,
the hose connection may be closed with a standard
threaded cap.
To Remove Bucket
1. Disconnect dehumidifier from electrical supply.
2. Pull bucket toward you, releasing actuator from
float assembly. (See Figures 6a and 6b.)
3. Reverse procedure to complete repairs.
To Remove Front Grille
1. Disconnect dehumidifier from electrical supply.
2. Remove two screws at lower front of grille. (See
Figure 6b.)
Note:
Bucket must be removed to gain
access to these screws.
3. Remove two screws in upper holes in rear of
cabinet flange. (See Figure 6d.)
4. Pull grille toward you so the two pins on each side
of grille will pull free of holes in cabinet. (See
Figure 6c and 6d.)
5. Pull grille down to release from top cover.
6. Reverse procedure to reassemble.
To Remove Top Cover
1. Disconnect dehumidifier from electrical supply.
2
.
Remove front grille.
3. Remove two screws on rear of dehumidifier
holding top cover to cabinet. (See Figure 6d.)
4. Slide cover to rear to release tabs from flange.
NOTE
: The Control Assembly is attached to the top
cover. This must be removed before the top cover
can be lifted up and off of the unit.
5. To release the Control Assembly from the top cover,
press in on the four tabs, on the underside of the
top cover. (See Figure 6g.) Electrical wires are still
connected to assembly, so be careful.
6. Lift cover up and off.
6. Reverse procedure to reassemble.
OPERATION & REPAIR INSTRUCTIONS
Figure 6a
Figure 6b
Figure 6c
Figure 6d
To Remove Wrapper
1. Disconnect dehumidifier from electrical supply.
2. Remove front grille and top cover.
3. Remove 14 screws from wrapper as shown in
Figures 6e and 6f.
Figure 6e
Figure 6f
4. Grasp wrapper on its left and right sides, pulling
outward, then pull toward you and lift free of
dehumidifier.
5. Reverse procedure to reassemble.
Figure 6g
Tabs