Pre Operation Leak Testing

GENERAL INFORMATION

Although all gas connections on the grill are leak tested prior to shipment, a complete gas tightness check must be
performed at the installation site due to possible shifting during shipment, installation or excessive pressure
unknowingly being applied to the unit. Periodically check the whole system for leaks and immediately check the
system if the smell of gas is detected.

BEFORE TESTING

Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame.

Mix a solution of equal parts mild detergent or liquid soap and water.

TESTING

1.

Turn off the burner control knobs.

2.

Turn the top knob of the fuel supply cylinder counterclockwise (right to left) two (2) rotations to open.

3.

Apply the soap solution to connections of the fuel supply assembly. If no soap bubbles appear, there is no gas
leak. If bubbles form at the connections, a leak is detected. If a leak is detected, immediately turn off the gas
supply, tighten any leaking fittings, turn gas on, and repeat steps 1-3.

4.

Turn off the knob on the fuel supply cylinder.

5.

Turn on the burner control knobs for a moment to release the pressure in the hose, then turn the control knobs
back off.

6.

Wash off soapy solution with cold water and towel dry.

Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the regulator.
Have a qualified service technician leak test the grill any time a part of the gas system is replaced.

Also it is recommended to perform a leak test at least once a year whether or not the L.P. gas supply cylinder has
been disconnected.

NOTE: When leak testing this appliance, make sure to test and tighten all loose connections, including the
side burner. A slight leak in the system can result in a low flame, or a hazardous condition. Most L.P. gas
tanks now come equipped with a leak detector mechanism internal to the tank; when gas is allowed to
escape rapidly, it shuts off the gas supply. A leak may significantly reduce the gas flow making the grill
difficult to light or causing low flames.

NOTE: If you cannot stop a gas leak, turn off the gas supply and call your local gas company or dealer you
purchased the appliance from. If necessary, replace the faulty part with the manufacturer’s recommended
replacement part. A slight leak could cause a fire.

Summary of Contents for FD26

Page 1: ...nic Ignition Welcome Product Registration 2 General Safety Instructions 3 Grill Features and Components 4 10 Grill Assembly 11 Gas Requirements Leak Testing 12 16 Lighting the Grill 17 18 Using the Grill 19 Care Maintenance 20 TroubleshootingYour Grill 21 22 Warranty 23 Visit the Frigidaire Web Site at http www frigidaire com ...

Page 2: ...pecific operating instructions for your model Use your grill only as instructed in this manual These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing operating and maintaining any appliance Please record your model and serial numbers below for future reference This information is found on the serial...

Page 3: ...ace and body as far away from the grill as possible when lighting to reduce the risk of burn Extinguish all flames and do not smoke while engaging gas and igniting the grill FOR OUTDOOR USE ONLY This appliance is not intended to be installed in or on recreational vehicles or boats CALIFORNIA PROPOSITION 65 WARNING The burning of gas cooking fuels generates some byproducts which are on the list of ...

Page 4: ...4 Grill Features FD26 1 Hood handle 2 Roll top grill hood 3 Warming shelf 4 Left side shelf 5 Electronic igniter 6 Control knob main burner 7 Right side shelf 8 Cart 9 Cart base FD26LKEC FD26NKEC ...

Page 5: ...5 Grill Components FD26 FD26LKEC ...

Page 6: ...11 DL4 LF26EC Left Side Shelf 1 12 DL4 OSFDEC Oblate Complex Slot Screw 1 4 20 12 8 13 DL4 VM26LK Gas Valve LP Main Burner 2 14 DL4 MTFDEC Manifold Retainer Bracket 2 15 DL4 MD26EC Manifold 1 16 DL4 GH26EC Gas Hose 1 17 DL4 LRFDEC Lighting Rod 1 18 DL4 OSFDEC Oblate Complex Slot Screw 5 32 32 12 5 19 DL4 RRFDLK Regulator LP 1 20 DL4 GT26EC Grease Tray 1 21 DL4 LDFDEC Lead 800mm 1 22 DL4 LDFDEC Lea...

Page 7: ...om Panel 1 30 DL4 CRFDEC 3 Castor 2 31 DL4 CBFDEC 3 Castor With Brake 2 32 DL4 DN26LK Dishing Nut 1 33 DL4 CT26EC Cart 1 34 DL4 RF26EC Right Side Shelf 1 35 DL4 RB26EC Rear Baffle 1 36 DL4 MB26EC Main Burner 2 37 DL4 FT26EC Flame Tamer 2 38 DL4 CG26EC Cooking Grid 2 39 DL4 WR26EC Warming Rack 1 ...

Page 8: ...8 FD26NKEC Grill Components FD26 ...

Page 9: ...F26EC Left Side Shelf 1 12 DL4 OSFDEC Oblate Complex Slot Screw 1 4 20 12 8 13 DL4 GVFDNK Gas Valve NG Main Burner 2 14 DL4 MTFDEC Manifold Retainer Bracket 2 15 DL4 MD26EC Manifold 1 16 DL4 GH26EC Gas Hose 1 17 DL4 LRFDEC Lighting Rod 1 18 DL4 OSFDEC Oblate Complex Slot Screw 5 32 32 12 5 19 DL4 GR26NK Gas Hose Connect Regulator 1 20 DL4 RRFDNK Regulator NG 1 21 DL4 LDFDEC Lead 800mm 1 22 DL4 LDF...

Page 10: ...ase Tray 1 30 DL4 BP26NK Bottom Panel 1 31 DL4 CRFDEC 3 Castor 2 32 DL4 CBFDEC 3 Castor With Brake 2 33 DL4 CT26EC Cart 1 34 DL4 RF26EC Right Side Shelf 1 35 DL4 RB26EC Rear Baffle 1 36 DL4 MB26EC Main Burner 2 37 DL4 FT26EC Flame Tamer 2 38 DL4 CG26EC Cooking Grid 2 39 DL4 WR26EC Warming Rack 1 ...

Page 11: ...he grill 4 Repeat the above steps to install the right side burner on right side panel Please note for the left side shelf insert the top two screws from the inside of the grill and the bottom two from the outside For the right side burner the four screws are all secured from the outside BATTERY ASSEMBLY 1 In order to install the battery remove the ignition button housing Please keep the positive ...

Page 12: ... 2 PSIG 3 5 kPa This grill must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 5 kPa The installation of this grill must conform with local codes or in the absence of local codes with National Fuel Code ANSI Z223 1a Installation in Canada must...

Page 13: ...ALLATION OF NATURAL GAS REGULATOR 1 The Natural Gas regulator has been attached to the manifold Attach the gas hose to the regulator See Fig 3 2 Link a quick connect fitting to the hose by hand Quick connect fitting not included See Fig 4 ...

Page 14: ...garage or any other enclosed area The L P cylinder must have an overfill protection device OPD on it The L P gas supply cylinder must be constructed and marked in accordance with the specifications for L P gas cylinders of the U S Department of Transportation DOT Cylinders Spheres and Tubes for the Transportation of Dangerous Goods L P TANK USE When turning the L P tank on make sure to open the va...

Page 15: ...15 Fig 5 Frigidaire ...

Page 16: ...on the fuel supply cylinder 5 Turn on the burner control knobs for a moment to release the pressure in the hose then turn the control knobs back off 6 Wash off soapy solution with cold water and towel dry Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the regulator Have a qualified service technician leak test the grill any time a part of the ga...

Page 17: ... flow 3 Always open the hood before attempting to light 4 Push and turn one of the control knobs counterclockwise to the HIGH position and immediately press the electronic igniter button You will hear a snapping sound It may be necessary to hold the electronic igniter button for about 4 seconds See Fig 6 NOTE If the burner does not light in 4 seconds turn the knob to the OFF position and wait 5 mi...

Page 18: ...dissipate Keep your face and hands as far away from the grill as possible Insert a lit extended match or lighter through the cooking grids to the burner Press the control knob and rotate left to the HIGH setting and continue to press the knob until the burner ignites Burner should light immediately quickly remove your hand to avoid getting burned If the burner does not light in 4 seconds turn the ...

Page 19: ...arance from the back of the grill to non combustible construction is required for the lid to fully open Storage of an outdoor gas cooking appliance indoor is permissible only if the cylinder is disconnected and removed from the appliance GENERAL RULES Do not leave the grill unattended while cooking 1 Make sure the grill has been leak tested and is properly located 2 Light the grill burners using t...

Page 20: ... of the metal Specks of grease can gather on the surface of the stainless steel and bake on to the surface and give a worn appearance For removal use a non abrasive oven cleaner in conjunction with a stainless cleaner NOTE Always scrub in the direction of the grain IGNITER ACCESS UNDER MAIN BURNER To remove igniter unscrew igniter push button and locking nut from front panel of the main burner and...

Page 21: ...ders insects and webs at least once a year to reduce this risk BEFORE CALLING CUSTOMER SERVICE If the grill does not function properly use the following checklist PROBLEM Grill will not light when the igniter button is pushed SOLUTION Is your gas supply turned on If this is an L P grill is there gas in your tank Check your gas level Is one of your burners turned on Allow up to four seconds of gas ...

Page 22: ...rner ports if clogged or dirty Check for leaks Note Pre Heating time can take from 5 to 10 minutes Check gas connection Look for kinked hose Make sure gas supply valve is fully open Gas level may be low Grill may be in need of cleaning Check flavor grids and cooking grates for excess food or grease build up Ensure grill is not placed directly in the path of wind Be sure drip tray is clean do not u...

Page 23: ...bill of sale delivery slip or some other appropriate payment record The date on the bill establishes the warranty period should service be required If service is performed it is in your best interest to obtain and keep all receipts This written warranty gives you specific legal rights You may also have other rights that vary from state to state Service under this warranty must be obtained by conta...

Reviews: