background image

Summary of Contents for FAZ12ES2A

Page 1: ... ft I 22 cm of where the power cord exits the air conditioner NOTE Do not use an extension cord Free movement of air in room to be cooled A large enough opening for the air conditioner Adequate wallsupportforweightof air conditioner Air conditioner weighs between 70 and 851bs 32 to 40 kg NOTE Cabinet louvers must not be obstructed Air must be able to pass freely through the cabinet louvers Parts S...

Page 2: ...3 1cm minimum Through the Wall Installation The wall opening measurements should be Width 22s 8 57 5 cm plus twice thickness of wood used to build frame Height 16 40 6 cm plus twice thickness of wood used to bui d frame Depth 2_ 2 6 4 cm minimum to 6V2 16 5cm maximum _ii_ii C t C A 16 40 6 cm B 225 _ 57 5 cm C Wood thickness D 21 2 6 4 minimum to 61 2 16 5cm maximum 2 ...

Page 3: ...e adhesive with your fingers Wipe with warm water and dry Do not use sharp instruments rubbing alcohol flammable fluids or abrasive cleaners to remove tape or glue These products can damage the surface of your air conditioner Handle the air conditioner gently 1 Remove the air conditionerfrom the carton and place iton cardboard A A Handle NOTE Do not lilt push pull or remove any expanded polystyren...

Page 4: ...the top channel on top of the air conditioner cabinet lining up the 3 holes in the top channel with the 3 holes on top of the air conditioner cabinet 3 Using 3 10 x pan head Phillips thread cutting screws attach the top channel to the air conditioner cabinet _ _ A Bottom view A Curtain housing B Curtain top channel on air conditioner A Curtain housing B Curtain bottom channel on air conditioner A ...

Page 5: ... Use a 3 16 drill bitto drill 3 starter holes 3 8 deep through the 3 holes in the cabinet and into the windowsill Attach cabinet to windowsill with 3 10 x 1 2 pan head Phillips screws A A A 6 1 A 10x pan head Phillips screws B Windowsill Check that air conditioner cabinet is tilted to the outside so that water will run to the outside Attach Side Curtains to Window Frame 1 Pull the left hand curtai...

Page 6: ... Do not block the louvers on the outside of the air conditioner It is the customer s responsibility and obligation to have this product installed by a qualified technician familiar with through the wall room air conditioner installations Option 1 Wood metal or plastic molding When using a wood metal or plastic molding the wood frame should line up with the inside wall as shown ABC I i A Molding B ...

Page 7: ...lf a bubble towards the rear 4 Reuse the insulation to seal opening between cabinetand frame 5 Use existing holes in sides and top of cabinetand 7 10 x 1 wood screws not provided to attach cabinet to frame NOTE Do not overtighten screws or the cabinet will distort and provide a poor air seal between cabinetand air conditioner 6 Caulk all outside wall openings around cabinet Excessive Weight Hazard...

Reviews: