4. CHECK FOR ANYTHING THAT COULD  BLOCK

AIRFLOW - check area outside of window for things

such as shrubs, trees, or awnings. Inside, be sure

furniture, drapes, or blinds will not stop  proper airflow.

5.

Check the available electrical service

 - power supply must

be the same as that shown on the unit serial nameplate.

(See Owner’s Guide for serial plate location.) Power cord

is 48''long. Be sure you have an  outlet near.

All models have a 3-prong service plug to provide proper

service and safe positive grouding. Do not change plug in

any way.  Do not use an adapter plug. If your present wall

outlet does not match your plug, call a qualified electrician

to make the needed change.

6.

Carefully unpack air conditioner 

- remove all packing

material. Protect floor or carpet from damage. Two

people should be used to move and install unit.

Avoid fire hazard or

electric shock. Do not use an extension
cord or an adapter plug. Do not remove
any prong from the power cord.

!

WARNING

Grounding type
wall receptacle

Do not under any
circumstances cut,
remove, or bypass the
grounding prong from
this plug.

power supply cord
with 3-prong
grounding plug.

Tools Required

a large flat blade screwdriver

tape measure

adjustable wrench or pliers

pencil

Level

Socket wrenches

Phillips screwdriver

Hardware (in plastic bag)

Qty.

2

3

1

4 ea.

2 ea.

2

10

Washer Head
Locking Screw
For window panels

3/4'' Long Hex-
Head Screw

Safety Lock

1/2'' Long Screw
and Locknut

3/4'' Long Flat
Head Bolt and
Locknut

Sill Angle Bracket

Long hex-head
locking screw for
top angle, side
retainer 5/16''
Long

Summary of Contents for FAS296N2A

Page 1: ...of 31 711 mm minimum to 42 1067 mm maximum width Open sash to a minimum of 19 483 mm FIG 1 2 Check condition of window all wood parts of window must be in good shape and able to firmly hold the needed screws If not make repairs before installing unit 3 Check your storm windows if your storm window frame does not allow the clearance required correct by adding a piece of wood as shown in FIG 2 or by...

Page 2: ... Carefully unpack air conditioner remove all packing material Protect floor or carpet from damage Two people should be used to move and install unit Avoid fire hazard or electric shock Do not use an extension cord or an adapter plug Do not remove any prong from the power cord WARNING Grounding type wall receptacle Do not under any circumstances cut remove or bypass the grounding prong from this pl...

Page 3: ... gasket to top angle above holes as shown in FIG 1 2 Install top angle and side retainers to cabinet as shown in FIG 1 1 2 Assemble Window Filler Panels 1 Place cabinet on floor a bench or a table 2 Slide I section of window filler panel into side retainer on the side of the cabinet see Figures 2 3 Do both sides 3 Insert top and bottom legs of window filler panel frame into channel in the top angl...

Page 4: ... window stool 4 5 Bottom Rail Seal 3 4 LONG HEX HEAD SCREW STOOL STOOL ANGLE Install Support Bracket 1 Hold each support bracket flush against outside of sill and tight to bottom of cabinet as shown below Mark brackets at top level of sill and remove 2 Assemlle sill angle bracket to support brackets at the marked position as shown Hand tighten but allow for any changes later 3 Install support brac...

Page 5: ...ow Filler Panels 1 Carefully raise window to expose filler panel locking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top 3 Close window behind top angle Install Window Lock and Sash Seal 1 Trim sash seal to fit window width Insert into space between upper and lower sashes 2 Attach right angle safety lock as shown 7 ...

Page 6: ... must never be blocked NOTE All parts neede for Thru The Wall Installation are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows and under truss bearing points etc 2 does not have plumbing or wiring inside 3 is near existing electrical outlets or where anothe...

Page 7: ...hannel resting on frame See FIG 2 following 3 1 LONG WOOD SCREW FIG 2 OPTIONAL Support brackets may be used Installation brakcets are recommended for walls under 5 thick Refer to Step 4 of Window Mounting for assembly of support brackets A wooden strip nailed to the outside wall should be used in conjunction with sill support angle brackets 5 Screw or nail cabinet wooden frame using shims if frame...

Page 8: ...is to build an in between frame of 2x4 s as shown in the Step 2 Prepare Wall illustrations but make it double framed on either side and install between masonry wall opening and cabinet Frame must be securely anchored to masonry wall opening This way gives very good louver clearance on either side of cabinet 3 Install a lintel to support masonry wall above cabinet Existing holes in cabinet can be u...

Reviews: