background image

2

FIG. 1B

FIG. 1C

FIG. 1D

FIG. 1E

6" ROUND DUCT

3-1/4" x 10"
TO 6"
ROUND
DUCT
TRANSITION

WALL CAP

WALL CAP

3-1/4" x 10" DUCT

ROOF CAP

3-1/4" x 10" DUCT

ADJUSTABLE ELBOW

WALL CAP

3-1/4" x 10" TO
6" ROUND
DUCT
TRANSITION

ROOF CAP

6" ROUND
DUCT

TOOLS AND
MATERIALS REQUIRED

TOOLS

Drill, electric or ratchet drive

1-1/4" Spade bit

Common head and phillips head screwdriver

Pliers

Tape measure or ruler and pencil

  For Ducted Installations ONLY:

  ❏

 

Saber saw or drywall saw

  ❏

 

Metal snips

MATERIALS

Electrical wiring and supplies of type to comply with local
codes

For Ducted Installations Only:

  ❏

 

Roof or wall cap

  ❏

 

Roof cement or caulk

  ❏

 

Duct and duct tape

For Installation on Kitchen Cabinets with Recessed Bottoms
Only:

Two 1" x 2" x 12" (approximate length) wood strips (pur-
chase locally)

Four 1-1/4"  long flat head wood screws (purchase locally)
to fasten strips to cabinet bottom

PLANNING DUCTWORK
INSTALLATION

Begin planning ductwork by deciding where the duct will run
between the range hood and the outside. For best performance,
use the shortest possible duct run and a minimum number of
elbows. There are several choices shown -  FIGS. 1A - 1E.

In more complex ducting situations, a 3-1/4" rectangular ducting
range hood can be converted to a round duct by means of a
transition.

FIG. 1A.

 Ducting directly through the wall (for range hoods

mounted on an exterior wall). Shown are two ways to duct through
an outside wall. If a wall cap is used directly off the back of the
hood, special care must be taken to make sure that the damper
in the damper/duct connector on the hood and damper in the
wall cap do not interfere with each other when the hood is oper-
ating. This could result in either inadequate air delivery or back
drafts. If this condition does exist, remove the hood damper flap.
Sometimes when using a wall cap it is easier to duct vertically
and then use an elbow as shown in 

FIG. 1B.

FIG. 1C.

 Ducting straight up through the roof using

3-1/4" x 10" rectangular duct. (For single story installations.)

FIG. 1D.

 Ducting between the ceiling joists (for multi-story instal-

lations) or through the soffit space above the cabinets (where
the soffit connects to an outside wall).

FIG. 1E.

 Straight up through the roof using 3-1/4” x 10” to 6”

round duct transition and 6" round duct (for single-story installa-
tions).

FIG. 1F.

 Straight up through the roof using 7" round duct (for

single-story installations). Requires optional damper Model 

Damp

Kit

 available from your local dealer.

FIG. 1A

7" ROUND DUCT

DAMPER

MODEL

“DAMPKIT”

ROOF CAP

FIG. 1F

Summary of Contents for F30WC Series

Page 1: ...ed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element IMPORTANT For Non ducted Ductfree Installation a Purchase non ducted filter separately b Remove and discard damper duct connector and louver cover See Step 4 in Prepare the Hood Page 2 c Follow all steps except steps inside dotted lines For Ducted Installation Follow all step...

Page 2: ...ations a 3 1 4 rectangular ducting range hood can be converted to a round duct by means of a transition FIG 1A Ducting directly through the wall for range hoods mounted on an exterior wall Shown are two ways to duct through an outside wall If a wall cap is used directly off the back of the hood special care must be taken to make sure that the damper in the damper duct connector on the hood and dam...

Page 3: ...above hood Seal joint between damper duct connector and hood with duct tape 8 7 round ducted discharge only Re install 7 round duct plate removed in Step 2 under PREPARING THE RANGE HOOD section For best performance line up the 7 round duct plate with the 7 round opening on hood Mount duct plate to hood with 2 screws from duct plate and 2 screws from 3 x 10 damper Install a 7 round damper purchase...

Page 4: ...om so that the duct will overlap the damper duct connector by 3 4 when the hood is installed ROOF CAPS Cut hole in roof slightly larger than duct so duct will line up easily with hood Trim shingles around hole so that they will fit snugly around hood of cap when cap is installed Assemble the duct work and tape all joints Run the duct work down to hood Trim duct parallel to roof pitch leaving 3 4 o...

Page 5: ...place wiring box cover and screw Make sure that all wir ing is safely contained inside NOTE For Ductfree Installations Only Install both filters Make sure that ductfree filter purchase separately is next to fan assembly with blue side next to blade Aluminum filter should be facing out FILTER REMOVAL Filters are removed by turning filter clip to the side and lifting filter or filters out In ducted ...

Page 6: ...rately 11 Filter Retainer 12 8B x 1 4 Hex Head Sheet Metal Screws 2 Req 13 Damper Flap 14 Damper Bushing 15 Damper Assembly Includes Key Nos 13 and 14 16 Nameplate Black Nameplate White Nameplate Biscuit 17 2 Speed Motor Switch Black 2 Speed Motor Switch White 2 Speed Motor Switch Biscuit 18 Light Switch Black Light Switch White Light Switch Biscuit 19 Motor Receptacle with Wires 20 Louver Cover B...

Page 7: ...7 ...

Page 8: ...RCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW BUT NOT LESS THAN ONE YEAR ELECTROLUX SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIM...

Reviews: