Section 3 Troubleshooting and Testing
3-14
Procedure
Letter
Q
Component Test
NOISE FILTER TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor. (See Warnings and Instructions on page 3-1)
4. Disconnect the leads to the primary of the power transformer.
5. Using an ohmmeter, check between the terminals as described in the following table.
If incorrect readings are obtained, replace the noise filter.
6. Reconnect all leads removed from components during testing.
7. Reinstall the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
MEASURING POINT
INDICATION OF OHMMETER
Between N and H
Between terminal N and LOAD
Short circuit.
Between terminal L and LOAD
Short circuit.
MONITOR
FUSE
NOISE FILTER
NOISE SUPPRESSION COIL
LINE CROSS CAPACITOR
LINE BYPASS
CAPACITOR
0.0033μF / 250V
LINE BYPASS
CAPACITOR
0.0033μF / 250V
H
LOAD
LOAD
N
RESISTOR
Open circuit.
Summary of Contents for CFMV152KW