background image

Summary of Contents for CFGF368GBA

Page 1: ...INSTRUCTIONS Note For appfiances installed in the State of Massachusetts see page 2 OVERALL DIMENSIONS 253 4 _ 29 7 8 _ 47 3 4 Maximum 36 _ 1 8 l T 36 44 5 8 _ Door Open 29 7 8 I _ l FRONT VIEW Minimum to 30 Side Wall Minimum _ Minimum to on Either 5 _ _ 1 8_ Cabinets on Side of Either Side Range 5 _ _L __ of Range SlIE 1 13 1 Maximum Depth _ for Cabinets Above Range Top Jl_r JL _l L Jl_rJL _l L I...

Page 2: ... operation This range requires fresh air for proper burner combustion Never leave children alone or unattended in the area where an appliance is in use As children grow teach them the proper safe use of all appliances Never leave the oven door open when the range is unattended Stepping leaning or sitting on the doors or drawers of this range can result in serious injuries and can also cause damage...

Page 3: ... wall make sure that screws completely penetrate dry wall and are secured inwood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing A a Locate the Bracket Using the Template Bracket may be located on either the left or right side of the range Use the information below to locate the bracket if template is not available Mark the floor or w...

Page 4: ...struct the flow of combustion and ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1inch greater than regulator manifold pressure Examples If regulator is set for natural gas 4 inch manifold pressure inlet pressure must be at least 5 inches if regulator has...

Page 5: ...p burners burning Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjusted for Natural Gas the manifold pressure is 4 For LP Propane Gas the manifold pressure is 10 5 Read electrical connection details below and connect electricity to range Before servicing disconnect elect...

Page 6: ... proper ignition and gas flame size Note The Burner Electrodes must be located properly in slot of each Burner Head See Fig 2 REMEMBER DO NOT ALLOW SPILLS FOOD CLEANING AGENTS OR ANY OTHER MATERIAL TO ENTER THE GAS ORIFICE HOLDER OPENING Always keep the Burner Caps and Burner Heads in place whenever the surface burners are in use 7 Electric Ignition Surface Burners Operation of electric igniters s...

Page 7: ...t the oven burner There is a time lapse from 30 to 60 seconds after the thermostat is turned ON before the flame appears at the oven burner When the oven reaches the dial setting the glowing igniter will go off The burner flame will go out in 20 to 30 seconds after the igniter goes OFF To maintain anygiven oven temperature this cycle will continue as long as the dial or display is set to operate A...

Page 8: ...nd serial numbers and a lot number or letter from the identification plate on your range Your identification plate also tells you the rating of the burners the type of fuel and the pressure the range was adjusted for when it left the factory Care Cleaning and Maintenance Refer to the Use Care Guide for cleaning instructions If removing the range is necessary for cleaning or maintenance shut off ga...

Reviews: