Page 41
Dishwasher Will Not Drain
Run the diagnostic test for drain.
Does the drain pump run?
Yes
Check for restricted
drain hose, pinched
crossover hose, or
plugged pump.
No
Remove the door panel and kick plate.
Remove electrical power and disconnect
the two wires from the drain pump.
Apply electrical power, run the
diagnostic test for drain and measure
the voltage drop between the two wires.
Defective control
board or broken
wire.
0 Volts
Remove electrical power.
Remove the stator winding
from the drain pump motor and
check it with an ohmmeter.
120 VAC
Open
Defective
stator
winding
Blocked pump.
Around 30
ohms