background image

4. The dehumidif ier must be installed on a level f loor that w ill support it 
    w ith a f ull bucket of  w ater.
5. There should be a minimum of  12 inches clearance around the dehumi-
    dif ier.

4. The dehumidif ier must be installed on a level f loor that w ill support it 
    w ith a f ull bucket of  w ater.
5. There should be a minimum of  12 inches clearance around the dehumi-
    dif ier.

Read a

all iinstructions b

bef ore u

using tthis d

dehumidif ier.  To reduce the risk of fire,

electric shock, or injury to persons when using your dehumidifier, follow basic
precautions, including the following:

For Your Saf ety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance. Read product labels for flammability and other warnings.

Child Saf ety Precautions

Destroy the carton, plastic bags, and any packing materials immediately after the
dehumidifier is unpacked. Children should never use these items for play.

Do not leave children unattended in an area where the appliance is operating.

Do not allow them to sit or stand on the appliance.

Electrical Inf ormation

For your safety and protection, this dehumidifier is equipped with a three-prong
grounding plug on the power cord. Do n

not, u

under a

any ccircumstances, ccut o

or

remove  tthe  rround  g

ground  p

prong  ff rom  tthe  p

plug.

Your  dehumidifier  must  be  plugged  directly  into  a  properly  grounded  and
polarized three-prong receptacle. If the wall receptacle you intend to use will not
accept a three-prong plug, or if you are not sure the outlet is adequately
grounded or protected by a time delay fuse or circuit breaker, have a qualified
electrician install the proper outlet according to the National Electrical Code and
applicable local codes and ordinances. Do  n

not  u

use  a

an  e

ex tension  ccord  o

or  a

an

adapter  p

plug.

Never unplug the dehumidifier by pulling on the power cord. Always grip the
plug firmly and pull straight out from the receptacle.

Do not pinch, bend, or knot the power cord.

Location

Selecting  a

a  L

Location

IM PORTA NT:
1. Dehumidif ier m

must b

be o

operated iin a

an e

enclosed a

area tto b

be m

most e

ef f ective.

Close  a

all  d

doors,  w

w indow s,  a

and  o

other  o

outside  o

openings  tto  tthe  rroom.  T

The

ef f ectiveness  o

of   tthe  d

dehumidif ier  d

depends  o

on  tthe  rrate  a

at  w

w hich  n

new

moisture-lladen  a

air  e

ent

the

ers

  rroom.

2. Place d

dehumidif ier iin a

a llocation tthat d

does n

not rrestrict a

airf low  tthrough tthe

f ront  o

of   tthe  u

unit  o

or  o

out  o

of   tthe  llouvers  o

on  tthe  llef t  sside  o

of   ccabinet.

3. A   d

dehumidif ier  o

operating  iin  a

a  b

basement  w

w ill  h

have  llittle  o

or  n

no  e

ef f ect  iin

drying  a

an  a

adjacent  e

enclosed  sstorage  a

area,  ssuch  a

as  a

a  ccloset,  u

unless  tthere

is  a

adequate  ccirculation  o

of   a

air  iin  a

and  o

out  o

of   tthe  a

area.  IIt  m

may  b

be  n

necessary

to  iinstall  a

a  ssecond  d

dehumidif ier  iin  tthe  e

enclosed  a

area  ff or  ssatisf actory

drying.

How  It W orks

W hen the unit is started, the fan begins to pull moisture-laden air across the
dehumidifying coils. The coils condense or draw moisture from the air, and air flows
through the side louvers into the room as dry, warm air. Moisture removed from air
is collected in a bucket on the fr
The unit is designed to operate between 41 F (5 C), and 96 F (35 C).
If the unit is switched off and needs to be switched on again, wait three minutes 
before doing so.
Make sure the tank is fitted correctly otherwise unit will not turn on.

ont of the dehumidifier.

Avoid fire hazard or

electric shock. Do not use an extension
cord or an adaptor plug. Do not remove
grounding prong from power cord.

Grounding  ttype
w all  rreceptacle

Pow er  ssupply
cord  w

w ith  3

3-p

prong

grounding  p

plug

Do  n

not,  u

under

any  ccircumstances,
cut,  rremove,
or  b

bypass  tthe

grounding  p

prong

f rom  tthis  p

plug.

Important Saf ety 
Instructions

3

Summary of Contents for 66129900901

Page 1: ...rformed it is in your best interest to obtain and keep all receipts Register Your Product The self addressed PRODUCT REGISTRATION CARD should be filled in completely signed and returned to the Frigidaire Company Contents 2 Warranty 3 Important Safety Instructions 3 Location 3 How It Works 4 OPERATION 6 CARE AND CLEANING 5 REMOVING COLLECTED WATER Operate dehumidifier only as instructed in this Own...

Page 2: ...ion to a grounded power supply of sufficient voltage replacement of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluoresc...

Page 3: ... the dehumidifier by pulling on the power cord Always grip the plug firmly and pull straight out from the receptacle Do not pinch bend or knot the power cord Location Selecting a a L Location IMPORTANT 1 Dehumidifier m must b be o operated i in a an e enclosed a area t to b be m most e effective Close a all d doors w w indow s a and o other o outside o openings t to t the r room T The effectivenes...

Page 4: ... knob until it points to the CONTINUOUS setting It is recommended you leave the unit running in the CONTINUOUS setting for the first three or four days until the sweating and dampness odors have stopped 4 3 After a few days when the Relative Humidity has declined rotate the HUMIDITY knob to a desired point on the dial so the room is kept at a comfortable concentration The unit will cycle on and of...

Page 5: ...e photographs below and empty the bucket e Replace the empty bucket back into the unit and once seated correctly the unit will start up again f You should hear a click when the bucket is in the correct position 4 To shut the unit down rotate the HUMIDITY knob to the OFF position Note the power indicator will still be lit when the unit is turned off Only removing the plug will extinguish these ligh...

Page 6: ...ter 2 Cabinet a Dust cabinet with an oil free cloth or using a damp cloth b Vacuum grill using brush attachment 3 Water Bucket a Clean bucket with warm water and detergent 6 2 Continuous Drainage a For constant drainage operation you will need a garden hose and a drain nearby to discharge the water into b Remove the bucket from the unit and set aside c Lift up the side flap located on the left sid...

Page 7: ... is adequate Air movement through dehumidifier is blocked Grill may be dirty Use brush attachment of vacuum cleaner to clean grill See Care and Cleaning Dehumidifier must be placed in a space that does not restrict air flowing into the rear coil or out of the front grill Dehumidifier has been installed or restarted recently The higher the moistuire in the room the longer the dehumidifier will oper...

Reviews: