background image

9

Air Conditioner Feature s

(continued)

DO THIS:

PRESS

YOU WILL SEE TIME CHOSEN:

STEP 8 — TO INCREASE

DELAYED START TIME:

Note: Tap or hold the UP arrow(

^

)  to increase delayed start time by .5 hours (up to 10 hours), then in 1 hour increments up

to 24 hours. The control will count down the time remaining until start (8, 7.5, 7, etc.).       

The unit will then come on in Cool and HI fan mode. The temperature maintained will be the same as you previously set. If you
want to change it,  Press ‘Cool” then Up or Down arrows until the desired temperature is indicated on the display. Press Timer
pad again to show remaining time.

Switching unit on at any time  will nullify this setting.

DO THIS:

PRESS

(if unit is not

running)

PRESS

YOU WILL SEE:

STEP 9 — TO SET FOR

DELAYED STOP:

Note: The unit must be running to make this setting.

Proceed as in step 8 to change the desired number of hours. The display will then continue to show hours and continue to maintain last
temperature setting until the control will time out and turn the unit off.

DO THIS:

PRESS ON/OFF

PAD

YOU WILL SEE:

STEP 10 — TO TURN UNIT OFF:

Note: The control will always maintain the last setting when it is restarted next time.

Summary of Contents for 309000834

Page 1: ...OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER ELECTRONIC CONTROL P N 309000834 10 99 ...

Page 2: ... to a grounded power supply of sufficient voltage replacement of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent...

Page 3: ...ioner Features 11 Care and Cleaning 12 Avoid Service Checklist 1996 White Consolidated Industries Inc All rights reserved NOTE This Owner s Guide provides specific operating instructions for your model Use the room air conditioner only as instructed in this Owner s Guide These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be...

Page 4: ...against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with outside protective cover in place This could result in mechanical damage within the air condi...

Page 5: ...ditioner included in a decorative kit To assemble follow these steps Before installation remove the tilt panel from the frame Grasping the panel from both sides gently pull to release then lift panel from pivot points at bottom of frame STEP 1 INSTALL DECORATIVE FRONT TO CABINET Decorative Front Loosen the screw to the left of the Electronic Control by 1 2 turn to easily install the decorative fro...

Page 6: ...ze yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the touch pad alone or with the remote Slip battery cover off and pull the piece of plastic from between the battery end and the connector For some applications the batteries supplied will first need to be installed Note Remember that ...

Page 7: ...eds will readjust back to LO as the room returns to the original set temperature 7 Note Tap or hold either up or down v button until the desired temperature is seen on the screen This temperature will be automatically maintained anywhere between 60F 15C and 90F 32C If you want the display to read the actual room temperature see step 5 Air Conditioner Features continued DO THIS PRESS TO RAISE PRESS...

Page 8: ...t running PRESS FAN ONLY CHOOSE ONE DO THIS PRESS ENERGY SAVER YOU WILL SEE STEP 6 TO USE THE ENERGY SAVER FEATURE Note In this mode when the compressor shuts off the fan will continue to run for another 3 minutes then shut off until cooling is needed as sensed by the room temperature control During this time it may come on for 3 minutes to sense whether cooling is needed then it will go off for 1...

Page 9: ... Up or Down arrows until the desired temperature is indicated on the display Press Timer pad again to show remaining time Switching unit on at any time will nullify this setting DO THIS PRESS if unit is not running PRESS YOU WILL SEE STEP 9 TO SET FOR DELAYED STOP Note The unit must be running to make this setting Proceed as in step 8 to change the desired number of hours The display will then con...

Page 10: ...ture within 2 3 degrees Fahrenheit between 60F and 90F degrees Fresh Air Vent Control The Fresh Air Vent allows the air conditioner to recirculate inside air OFF draw air into the room FRESH AIR or exhaust stale air to the outside VENT See Figures 1 2 3 for this operation The OFF position is used when MAXIMUM cooling is desired It may also be for room air re circulation without cooling when the se...

Page 11: ...olish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner The cabinet front can be removed for more thorough cleaning Refer to Front Installation in this manual Clean the front in a sink using liquid dishwashing detergent and warm water Rinse thoroughly and dry Replace cab...

Page 12: ...Temperature set too cold for night time cooling To defrost the coil set selector to a FAN position Then set temperature warmer Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too high Set temperature lower Vent set at OPEN position Set vent at C...

Reviews: