background image

3

Record Your Model and Serial Numbers

Record in the space provided below the model and serial numbers. On all models, the serial

plate is located on the outside of the cabinet.

Model No. 

Serial No. 

Register Your Product

The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed

and returned to the Frigidaire Company.

2

Warranty

3

Product Registration

3

Normal Sounds

4

Important Safety Instructions

4

Operation of Current Device

5

Using Air Conditioner

5-9

Air Conditioner Features

10

Care and Cleaning

10

Energy Saving Ideas

11

Avoid Service Checklist

Vibration

Unit  may  vibrate  and  make  noise

because  of  poor  wall  or  window

construction or incorrect installation.

High Pitched Chatter

Today’s high efficiency compressors

may  have  a  high  pitched  chatter

during the cooling cycle.

Sound of Rushing Air

At the front of the unit, you may

hear the sound of rushing air

being moved by the fan.

Gurgle/Hiss

 “Gurgling or hissing” noise may be heard

due  to  refrigerant  passing  through

evaporator during normal operation.

Pinging or Swishing

Droplets  of  water  hitting

condenser  during  normal

operation may cause “pinging

or swishing” sounds.

Product Registration

Contents

Normal Sounds

NOTE:

  This  USE & CARE MANUAL 

provides specific  operating  instructions 

for  your model.  Use  the  room  air 

conditioner  only as instructed in this USE 

& CARE MANUAL  instructions are not 

meant to cover every possible  condition 

and  situation  that  may occur. Common 

sense and caution must be practiced  when 

installing,  operating,  and maintaining any 

appliance.

SZ000728(En)-Yaokong

09/20/2005, 5:30 PM

3

Summary of Contents for 220218A007

Page 1: ...USE CARE MANUAL READ AND SAVE THESE INSTRUCTIONS P N 220218A007 SZ000728 En Yaokong 09 20 2005 5 30 PM 1 MULTI STEP SPEED ELECTRONIC CONTROLS ...

Page 2: ... not in ordinary household use The consumer shall pay for such service calls 3 Damages caused by services performed by persons other than authorized Frigidaire servicers use of parts other than Frigidaire Genuine Renewal Parts obtained from persons other than such servicers or external causes such as abuse misuse inadequate power supply or acts of God 4 Products with original serial numbers that h...

Page 3: ... High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting condenser d...

Page 4: ...er cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner with outside protective cover...

Page 5: ...URN UNIT ON NOTE The following instructions represent the Unit Controls the same instructions can be used for the Remote Control SZ000728 En Yaokong 09 20 2005 5 30 PM 5 DISPLAYS TEMPERATURE TIME FAN SPEED ACTIVATES TIMER CHECK FILTER RESET BUTTON SETS MODE TURNS UNIT ON OR OFF AUTO TEMP FEATURE SLEEP MODE SETS FAN SPEEDS DO THIS PRESS ON OFF BUTTON YOU WILL SEE YOU WILL SEE Note Tap or hold eithe...

Page 6: ...room temperature dictates For example if the room doesn t get too warm it will stay at the slowest speed If the room temperature rises quickly such as a door being opened it will automatically go to the highest speed The fan speeds will re adjust back to the slowest speed as the room returns to the original set temperature DO THIS PRESS AUTO TEMP BUTTON LIGHT ON TO OPERATE ON FAN ONLY YOU WILL SEE...

Page 7: ...TTON THEN DO THIS PRESS TEMP TIMER SET BUTTON Then to adjust timer setting tap or hold the UP arrow or the DOWN arrow to change delay timer at 5 hour increments up to 10 hours then by 1 hour increments up to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Delay Start mode automatically selects cooling with maximum Fan Speed The temperature maintained will be the...

Page 8: ...L SEE Note In this MODE the set temperature will increase by 2 degrees F 30 minutes after the mode is selected The temperature will then increase by another 2 degrees F after an additional 30 minutes This new temperature will be maintained for 7 hours before it returns to the or iginally selected temperature This ends the Sleep MODE and the unit will continue to operate as originally programmed Th...

Page 9: ...t the air flow Up or Down and Left or Right throughout the room as needed Rotate the Auger Wheel Up or Down until the desired direction is obtained The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time The control will main...

Page 10: ... controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Note To prevent rust or electrical connections from being damaged store air co nditioner in an upright and a dry pl...

Page 11: ...he coil set FAN ONLY Mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lowe...

Reviews: