Air conditioner will not operate.

Air from unit does not feel cold
enough.

Air conditioner cooling, but room is
too warm - ice forming on cooling
coil behind decorative front.

Air conditioner cooling, but room is
too warm - NO ice forming on
cooling coil behind decorative front.

Air conditioner turns on and off
rapidly.

Noise when unit is cooling.

Water dripping INSIDE when unit is
cooling.

Water dripping OUTSIDE when unit
is cooling.

Remote Sensing Deactivating
Prematurely (Some Models).

Room Too Cold.

Avoid Service Checklist

Before calling for service, review this list. It may save you time and expense. This list
includes common occurrences that are not the result of defective workman-ship or
materials in this appliance.

OCCURRENCE

SOLUTION

Wall plug disconnected. Push plug firmly into wall outlet.

Plug Current Device Tripped. Press the RESET button.

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

Control is OFF. Turn Control ON and set to desired setting.

Room temperature below 6

2

°F (1

7

°C). Cooling may not occur until room temperature rises above 6

2

°F (1

7

°C).

Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.

Reset to a Lower temperature.

Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart
when set in the COOL mode.

Outdoor temperature below 6

2

°F (1

7

°C). To defrost the coil, set FAN ONLY Mode.

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY Mode.

Temperature is set too Low for night-time cooling. To defrost the coil, set to FAN ONLY Mode. Then, set Tem-
perature to a Higher setting.

Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.

Temperature is set too High. Set temperature to a Lower setting.

Air directional louvers positioned improperly. Position louvers for better air distribution.

Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.

Doors, windows, registers, etc. open - cold air escapes. Close doors, windows, registers, etc.

Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor and
furniture.

Dirty air filter - air restricted. Clean air filter.

Outside temperature extremely hot. Set FAN speed to a faster setting to bring air past cooling coils more
frequently.

Air movement sound. This is normal. If too loud, set to a slower FAN setting.

Window vibration - poor installation. Refer to installation instructions or check with installer.

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation
instructions - check with installer.

Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.

• Remote control not located within range. Place remote control within 20 feet & 180°, radius of the front of the

unit.

• Remote control signal obstructed. Remove obstruction.

• Set temperature too low. Increase set temperature.

• Remote Sensing activated (on some models) and remote control located in Hot Spot - Relocate remote

control or deactivate remote sensing.

If These Solutions Fail, Call 1-800-444-4944 For Frigidaire Service.

Summary of Contents for 220211A243

Page 1: ...USE CARE MANUAL ELECTRONIC CONTROL AIR CONDITIONER READ AND SAVE THESE INSTRUCTIONS P N 220211A243 ...

Page 2: ...tions or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not cover the following 1 CONSEQUENTIAL OR ...

Page 3: ...lation High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting conde...

Page 4: ...rds proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air ...

Page 5: ...uctions can be used for the Remote Control DO THIS PRESS ON OFF BUTTON ON OFF SET TEMP FAN SPEED Mode Energy Saver Sleep Light Clock Cancel Timer Fan Reset Lock F Fig A ACTIVATE TIMERS REMOTE CONTROL TURNS UNIT ON OR OFF ADJUSTS TEMP TIMES SETS MODES SET FAN SPEEDS ENERGY SAVER MODE ON OFF SET TEMP FAN SPEED Mode Energy Saver Sleep Light Clock Cancel Timer Fan Reset Lock F Clean Air Follow Me Fig ...

Page 6: ...ure See To Operate on Fan Only sec tion on Page 7 TO USE AUTO TEMP FEATURE YOU WILL SEE DO THIS PRESS FAN BUTTON SELECT AUTO TEMP Note Fan starts at High Speed and adjusts to a slower speed as the room temperature dictates For example if the room doesn t get too warm it will stay at the slowest speed If the room temperature rises quickly such as a door being opened it will automatically go to the ...

Page 7: ...er setting has been originally selected When the compressor switches back to the cooling mode then the fan speed will return to the original setting DO THIS PRESS MODE BUTTON CHOOSE FAN LIGHT On LIGHT On 62 72 TO OPERATE ON FAN ONLY Note Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air Remember to open the vent during this function but kee...

Page 8: ... maintained will be the same as previously set To change the set temperature press COOL then Up or Down arrows until the desired temperature is indicated on the display After 5 seconds the control will automatically change the display back to the hours re maining until the unit will start stop Turning the unit ON or OFF at any time will cancel the Delay Start Stop function The Delay Start Stop Fea...

Page 9: ... ON NOTE Remote display is actual temperature at remote control only ON OFF SET TEMP FAN SPEED Mode Energy Saver Sleep Light Clock Cancel Timer Fan Reset Lock F Clean Air Follow Me Note This feature can be activated from the remote control ONLY the unit must be in a cooling mode To activate the remote sensing feature point the remote control towards the unit and press the remote sensing button Nex...

Page 10: ...TON FAULT CODES WARNING CODES If the display reads AS or ED a sensor has failed Contact your Authorized Frigidaire Service Center In the fan mode if LO or HI is displayed this means the room temperature is outside the unit set points of 99o F 37o C HI or 32o F 0o C LO YOU WILL SEE ...

Page 11: ...degrees Fahrenheit or degrees Celsius To convert from one to the other and back press and hold the TEMP TIMER Up and Down buttons together for 3 seconds The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time 8 WAY Air Direct...

Page 12: ...ping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Care and Cleaning Energy Saving Ideas Do not block air flow i...

Page 13: ...defrost set to FAN ONLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lower setting Air directional louvers positioned improperly Position louvers for better air distribution ...

Reviews: