background image

11

Clean your air conditioner occasionally to keep it looking new. 

Be sure to unplug the

unit before cleaning to prevent shock or fire hazards.

Air Filter Cleaning

The air filter should be checked at least once a month to see if cleaning is necessary.
Trapped particles in the filter can build up and cause an accumulation of frost on the
cooling coils.
• Push the vent handle to the Vent Closed position (where applicable).
• Open the front panel.
• Grasp the filter by the center and pull up and out.
• Wash the filter using liquid dishwashing detergent and warm water. Rinse filter

thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry
before replacing.

• Or, instead of washing you may vacuum the filter clean.

Cabinet Cleaning

• Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and

front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution
of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.

• Never use harsh cleaners, wax or polish on the cabinet front.
• Be sure to wring excess water from the cloth before wiping around the controls. Excess

water in or around the controls may cause damage to the air conditioner.

• Plug in air conditioner.

Winter Storage

If you plan to store the air conditioner during the winter, remove it carefully from the
window according to the installation instructions. Cover it with plastic or return it to the
original carton.

Air Conditioner Features

(continued)

(8-WAY)

AUGER WHEELS

Air Directional Louvers

Air directional louvers control air flow direction. Your air conditioner has the louver type
described below.

Auger Type

The louvers will allow you to direct the air flow Up or Down and Left or Right throughout
the room as needed. Rotate the Auger Wheels until the desired Left/Right direction is
obtained. Pivot horizontal louvers until the desired Up/Down direction is obtained.

Care and Cleaning

SZ000302(En)-YaoKong(1018)

10/25/2004, 2:33 PM

11

Summary of Contents for 220201d011

Page 1: ......

Page 2: ... of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation 6 Replacement of light bulbs and or fluorescent tubes on models with these features This warranty does not c...

Page 3: ...tter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water hitting condenser during normal oper...

Page 4: ... shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper recept...

Page 5: ...CONTROL OPERATING INSTRUCTIONS Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the touch pad alone or with the remote The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the follo...

Page 6: ...is pressed the motor speed will slow down at multiple intervals 90 distinct settings to a minimum setting of 10 To speed the motor up press the FASTER button The speed will increase at multiple intervals to a maximum setting of 99 After 5 seconds the control will automatically change back to displaying the set temperature Note Tap or hold either up or down button until the desired temperature is s...

Page 7: ...7 ...

Page 8: ...8 ...

Page 9: ...9 ...

Page 10: ...e more features in your control that you should become familiar with The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time The control will maintain the set temperature within 2 degrees Fahrenheit between 60F and 90F degree...

Page 11: ... a cloth dampened in a solution of warm water and mild liquid dishwashing detergent Rinse thoroughly and wipe dry Never use harsh cleaners wax or polish on the cabinet front Be sure to wring excess water from the cloth before wiping around the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air ...

Page 12: ...ection To defrost set to FAN ONLY Mode Temperature is set too Low for night time cooling To defrost the coil set to FAN ONLY Mode Then set Tem perature to a Higher setting Dirty air filter air restricted Clean air filter Refer to Care and Cleaning section Temperature is set too High Set temperature to a Lower setting Air directional louvers positioned improperly Position louvers for better air dis...

Reviews: