background image

Owner’s & Installation manual

 

2

 

 

Temperature

 

 

Mode

 

Outdoor 

temperature

 

Room 

temperature

 

Water inlet 

temperature

 

 

Cooling operation

 

0°C

43°C

 

 

-15°C

24°C

 

 

17°C

32°C

 

 

0°C

30°C

 

 

3°C

20°C

 

 

30°C

80°C

 

Heating operating

 

(cooling only type without)

 

 

 

CAUTION

 

 

 

Ground the air conditioner.

 

Do  not  connect  the  ground  wire  to  gas  or  water  pipes, 
lightning  rod  or  a  telephone  ground  wire.  Incomplete 
grounding may result in electric shocks.

 

 

Be sure to install an earth leakage breaker.

 

Failure  to  install  an  earth  leakage  breaker  may  result  in 
electric shocks.

 

 

Connect  the  outdoor  unit  wires,  then  connect  the  indoor 
unit wires.

 

You  are not allowed to  connect the  air  conditioner  with  the 
power  source  until  wiring  and  piping  the  air  conditioner  is 
done.

 

 

While  following  the  instructions  in  this  installation 
manual,  install  drain  piping  in  order  to  ensure  proper 
drainage  and  insulate  piping  in  order  to  prevent 
condensation.

 

Improper  drain  piping  may  result  in  water  leakage  and 
property damage.

 

 

Install the indoor and outdoor units, power supply wiring 
and  connecting  wires  at  least  1  meter  away  from 
televisions  or  radios  to  prevent  image  interference  or 
noise.

 

Depending on the radio waves, 1 meter may not be sufficient 
enough to eliminate the noise.

 

 

This  appliance  can  be  children  aged  from  8  years  and 
above  and  persons  with  reduced  physical,  sensory  or 
mental  capabilities  or  lack  of  experience  and  knowledge 
if  they  have  been  given  supervision  or  instruction 
concerning  use  of  the  appliance  in  a  safe  way  and 
understand  the  hazards  involved. Children  shall  not  play

 

2. INSTALLATION INFORMATION

 

 

To  install  properly,  please  read  this  "Owner’s  &  Installation 
manual" at first.

 

 

The air conditioner must be installed by qualified persons.

 

 

When  installing  the  indoor  unit  or  its  tubing,  please  follow  this 
manual as strictly as possible.

 

 

If the air conditioner is installed on a metal part of the building, it 
must  be  electrically  insulated  according  to  the  relevant 
standards to electrical appliances.

 

 

When  all  the  installation  work  is  finished,  please  turn  on  the 
power only after a thorough check.

 

 

Regret  for  no  further  announcement  if  there  is  any  change  of 
this manual caused by product improvement.

 

 

3. FUNCTIONS & FEATURES

 

 

Nested in the ceiling, space-saving and noble.

 

 

High capacity of cooling / heating performance, high 
efficiency and energy-saving.

 

 

Adjust the indoor temperature rapidly and averagely. 

Low noise design.

 

The air outlet is laid out in the way you desire.

 

 

 

4. ACCESSORIES

 

Table 4-1

 

with the appliance. Cheaning and user maintenance shall 
not be made by children without supervision.

 

Accessory Name 

Qty. 

Sharp

 

Purpose

 

 

DISPOSAL

Do not dispose this product as unsor- 

ted municipal waste. Collection of such waste sepa- 
rately for  special treatment is necessary.

 

Do not dispose of electrical appliances as unsorted 
municipal waste, use separate collection facilities.

 

Contact  your  local  government  for  information  regarding 
the collection systems available.

 

If  electrical  appliances  are  disposed  of  in  landfills  or  dumps,

 

Owner’s & installation manual 

1

 

 

Accessional plastic  water tray 

1

 

(

no air return box type without

 

 

 

5. OPERATION RANGE

 

This manual

 

hazardous substances can leak into the groundwater and get

 

Use the system in the following temperature for safe and

 

into the food chain, damaging your health and well-being.

 

effective operation.

 

Table 5-1

 

 

Disconnect the power  supply before  cleaning  and 
maintenance. Use dry cloth to clean the unit.

 

 

Don't install the air conditioner in the following locations:

 

 

There is petrolatum existing.

 

 

There is salty air surrounding (near the coast).

 

 

There is caustic gas (the sulfide, for example) existing 

in the air (near a hot spring).

 

 

The Volt vibrates violently (in the factories). 

In buses or cabinets.

 

In kitchen where it is full of oil gas.

 

 

There is strong electromagnetic wave existing. 

There are inflammable materials or gas.

 

There is acid or alkaline liquid evaporating. 

Other special conditions.

 

 

 

 

 

 

 

                                     

NOTE

 

 

1  If  air  conditioner  is  used  outside  the  above  conditions,  it 

may cause the unit to function abnormally.

 

 

2  The  phenomenon  is  normal  that  the  surface  of  air 

conditioning  may  condense  water  when  the  relative  larger 

humidity in room, please close the door and window.

 

 

3  Optimum  performance  will  be  achieved  within  these 

operating temperature range.

 

 

4  Water system operating  pressure:   Max:   1.6MPa,  Min:

 

0.15MPa.

 

Summary of Contents for KFC-PD-2T-1000D

Page 1: ...V800 KFC PD 2T 800D MKT3 V1000 KFC PD 2T 1000D MKT3 V1200 KFC PD 2T 1200D MKT3 V200F KFC PD 4T 200D MKT3 V300F KFC PD 4T 300D MKT3 V500F KFC PD 4T 500D MKT3 V600F KFC PD 4T 600D MKT3 V800F KFC PD 4T 8...

Page 2: ...des right and left whit these references MKT3 V200 KFC PD 2T 200D RIGHT MKT3 V400 KFC PD 2T 400D RIGHT MKT3 V200F KFC PD 4T 200D RIGHT MKT3 V300F KFC PD 4T 300D RIGHT MKT3 V500F KFC PD 4T 500D RIGHT M...

Page 3: ...ries parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not...

Page 4: ...horough check Regret for no further announcement if there is any change of this manual caused by product improvement 3 FUNCTIONS FEATURES Nested in the ceiling space saving and noble High capacity of...

Page 5: ...unit where connotative heat is emitted from a heat source directly CAUTION Scope of dismantling the ceiling Please keep the ceiling horizontal Reinforce the beams and girders of the ceiling lest vibra...

Page 6: ...ally Lack of horizontality may cause water leak Connect the duct The duct length is determined according to the external static pressure Install the wire control switch For installation of the wire co...

Page 7: ...585 685 905 841 941 1161 683 783 1003 1233 1338 1205 1310 1461 1566 1303 1408 1628 1600 1856 1698 1794 1766 2022 1864 NOTE The above figures is an instance models which would be different from the on...

Page 8: ...es are smooth and the adapters are sealed Newly built rooms should undergo the drain test before the ceiling is laid NOTE Be sure to perform heat insulation for the drainpipe of the indoor unit Otherw...

Page 9: ...n fixed wiring The appliance shall be installed in accordance with national wiring regulations Be sure to locate the power wiring and the signal wring well to avoid cross disturbance Do not turn on th...

Page 10: ...UE YELLOW RED HI SPEED MI SPEED LO SPEED 10 1 Wiring Diagram ON ON S8S 7 S6 OF F S5 S4 OF F LED 4 SW1 SW2 CN3 MAIN BOAD ALARM EARTH CN1 CN2 CN5 CN8 MOTOR1 MOTOR2 L N HI MID LOW N POWER IN YELLOW GREEN...

Page 11: ...300CFM 51WA single m otor 400CFM 68WA single m otor 500CFM 85WA single m otor 600CFM 102WA single m otor 800CFM 136WA double m otor 1000CFM 170WA double m otor 1200CFM 204WA double m otor Not set mode...

Page 12: ......

Reviews: