Explanation of symbols displayed on the indoor unit or outdoor unit 
(For the unit adopts R-32 Refrigerant only):

 

 

 

 

 

WARNING

 

This symbol shows that this appliance used a flammable refrigerant. If the 
refrigerant is leaked and exposed to an external ignition source, there is

 

a risk of fire.

 

 

 

CAUTION

 

This symbol shows that the operation manual should be read carefully.

 

 

 

CAUTION

 

 

This  symbol  shows  that  a  service  personnel  should  be  handling  this 
equipment with reference to the installation manual.

 

 

 

CAUTION

 

 

 

 

 

CAUTION

 

This  symbol  shows  that  information  is  available  such  as  the  operating 
manual or installation manual.

 

 

ELECTRICAL WARNINGS

 

 

Only use the specified power cord. If the power cord is damaged, it must be replaced by the 

manufacturer or certified service agent.

 

 

Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty 

plugs can cause fire or electric shock.

 

 

Do not 

pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling 

directly on the cord can damage it, which can lead to fire or electric shock.

 

 

Do not 

use an extension cord, manually extend the power cord, or connect other appliances to 

the same outlet as the air conditioner. Poor electrical connections, poor insulation, and insufficient 

voltage can cause fire.

 

 

Turn off the device and pull the plug before cleaning. Failure to do so can cause electrical shock.

 

 

Do not 

clean the air conditioner with excessive amounts of water.

 

 

Do not 

clean the air conditioner with combustible cleaning agents. Combustible cleaning agents 

can cause fire or deformation.

 

 

If the air conditioner is used together with burners or other heating devices, thoroughly ventilate 
the room to avoid oxygen deficiency.

 

 

Turn off the air conditioner and unplug the unit if you are not going to use it for a long time.

 

 

Turn off and unplug the unit during storms.

 

 

Make sure that water condensation can drain unhindered from the unit.

 

 

Do not 

operate the air conditioner with wet hands. This may cause electric shock.

 

 

Do not 

use device for any other purpose than its intended use.

 

 

Do not 

climb onto or place objects on top of the outdoor unit.

 

 

Do not 

allow the air conditioner to operate for long periods of time with doors or windows 

open, or if the humidity is very high.

 

CLEANING AND MAINTENANCE WARNINGS

 

CAUTION

 

Saf
et

P

recau

tio

n

s

 

Summary of Contents for Kaysun Casual CF Series

Page 1: ...KAY CF 35 DN7 KAY CF 52 DN7 KAY CF 71 DN7 KAY CF 26 DR8 KAY CF 35 DR8 KAY CF 52 DR8 KAY CF 71 DR8 IMPORTANT NOTE Readthismanualcarefullybeforeinstalling or operating your new air conditioning unit Mak...

Page 2: ...Table of Contents Owner s Manual Safety Precautions 04 Unit Specificationsand Features 06 SAFETY FIRST 2 Manual Operation Without Remote 11 0 1...

Page 3: ...med as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of theperson competent in the use...

Page 4: ...be rotating at high speeds Do not use flammable sprays such as hair spray lacquer or paint near the unit This may cause fire or combustion Donotoperatetheairconditionerinplacesnearoraroundcombustibleg...

Page 5: ...ndamageit whichcanleadtofireorelectricshock Donotuseanextensioncord manuallyextendthepowercord orconnectotherappliancesto the same outlet as the air conditioner Poor electrical connections poor insula...

Page 6: ...temperature in one second interval In other modes the unit will display your temperaturesetting Display Code Meanings In Fan and Dry mode the unit will display the room temperature When error occurs...

Page 7: ...7 the infrared remote is not included in this literature package...

Page 8: ...used outside of these ranges certain safety protectionfeatureswillactivateandcausetheunittoperformlessthanoptimally Inverter Split Type COOL mode HEAT mode DRY mode RoomTemperature 17 C 32 C 63 F 90...

Page 9: ...conditioner using your mobile phoneandaWirelessconnection For the USB device access replacement maintenance operations must be carried out by professional staff Louver Angle Memory some units When tur...

Page 10: ...he SWING DIRECT button for 3 seconds Press it again to stop the automatic function Setting horizontal angle of air flow The horizontal angle of the airflow must be set manually Gripthedeflectorrod See...

Page 11: ...sleep When in COOL mode the unit will increase the temperature by 1 C 2 F after 1 hour and will increase an additional 1 C 2 F after another hour When in HEATmode the unit willdecreasethetemperatureby...

Page 12: ...activateFORCEDAUTOmode 4 Press the MANUAL CONTROL buttonagain to activate FORCED COOLING mode 5 Press the MANUAL CONTROL button athird time to turn the unit off 6 Close the frontpanel Manual control b...

Page 13: ...leanthisair freshening filter with a hand held vacuum 5 Clean the large air filter with warm soapy water Besuretouseamilddetergent Remove air freshening filter from back of larger filter some units Ca...

Page 14: ...nder the CL indicatorwillflash again when you restart the unit Air Filter Replacement Reminder After2 880hoursofuse thedisplaywindowon theindoorunitwillflash nF Thisisareminder to replaceyourfilter Af...

Page 15: ...r long periods of non use or before periods of frequent use do the following Check fordamaged wires Clean all filters Checkforleaks Replace batteries Make sure nothing is blocking all air inlets and o...

Page 16: ...mpressor The unit will continue operating when the temperature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between the room sairand theconditioned...

Page 17: ...Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use whichwillbeemittedwhentheunitisturnedon This can be mitigated by covering the un...

Page 18: ...runitisblocked Turn the unit off remove the obstructionandturnitbackon Doors and windows are open Make sure that all doors and windows are closed while operating theunit Excessive heat is generated by...

Page 19: ...voltage Poor heating performance The outdoor temperature is extremely low Useauxiliaryheating device Cold air is entering through doors and windows Make sure that all doors and windows areclosed durin...

Page 20: ...s Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge The manufacturer will t...

Page 21: ...e design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CS78421 548 754 CS372U AF 16122000002735 201710...

Page 22: ......

Reviews: