3. Mounting and requirements for the surrounding area  

 

3.1. Requirements for the surrounding area 

 
Your friendlyway d-sign 12" was specially developed for use in enclosed areas and has specific requirements 
for the surrounding area: 
• Permissible ambient temperature:  15 - 30°C 
• No sources of warmth or heat (direct sunlight, heater) in the immediate vicinity, no direct effects of heat. 
• No high relative humidity 

 

 

The machine must only be operated under the environmental conditions listed above.  
Please take this into consideration when selecting a place to set up the device. 

 
 

3.2. Mounting 

 

The d-sign 12’’ in its basic model is mounted in a wall. For mounting a corresponding wall break should be 
prepared (312x248 mm). 
 

Instructions on mounting into the wall: 

1. Remove the front panel by using a slotted screwdriver as a lever. 
2. Place the device in the wall and tighten the 4 hitches with a Phillips screwdriver until the housing is fixed. 
3. Set the front panel in the housing and press on the front panel with a flat hand until the panel is caught.

 

 

Instructions on disassembling from the wall: 

1. Remove the front panel by using a slotted screwdriver as a lever. 
2. Loose the hitches with a Phillips screwdriver until they swivel into the housing. 
3. Remove the housing from the wall. 
 
Optionally, the d-sign 12" can be also mounted on a stand. 

 

 

7

Summary of Contents for D-Sing 12

Page 1: ......

Page 2: ......

Page 3: ...tion 6 3 Mounting and requirements for the surrounding area 7 3 1 Requirements for the surrounding area 7 3 2 Mounting 7 4 Connecting the unit and placing it in service 8 4 1 Connecting terminal to th...

Page 4: ...o special facilities of separate device variants or other accessories please refer to respective documentation This document describes how to set up and start up your terminal what settings are availa...

Page 5: ...per IEC 950 EN60950 is only ensured if the housing is fully assembled and the rear side covers for installation locations are in place electric shock cooling fire protection radio interference Before...

Page 6: ...ly with a damp cloth and gentle cleaning agents Do not directly spray cleanser onto the unit Screen Clean with standard window cleansers To prevent exposure to moisture do not directly spray cleanser...

Page 7: ...ice 3 2 Mounting The d sign 12 in its basic model is mounted in a wall For mounting a corresponding wall break should be prepared 312x248 mm Instructions on mounting into the wall 1 Remove the front p...

Page 8: ...ice from a grounded alternating current socket for a 220 240 V 50 Hz power supply Connection Connect the device to the power supply with the power connection cord The device is ready for operation 4 2...

Page 9: ...nd no later terminal upgrade can be performed as a rule If you have questions regarding the operation and maintenance of optional devices as well as special accessories please refer to the respective...

Page 10: ...nt temperature permissible in the range 15 C 30 C Standard equipment 12 LCD display PC Pentium M 1 1 GHz 512 MB RAM Windows XP Professional REAR VIEW SIDE VIEW FRONT VIEW Subject to technical modifica...

Page 11: ...ppy to assist you with any questions and problems You can reach us on our hotline at 1 800 374 36 35 only in Germany or at 49 0 89 95 97 91 500 or by e mail at support friendlyway com We offer telepho...

Page 12: ...12 NOTES...

Page 13: ...as well as 93 97 EEC and the low voltage regulation 73 23 EEC as modified by 93 68 EEC This declaration is submitted by friendlyway AG Feringastr 9 85774 M nchen Unterf hring The relevant tests were...

Page 14: ......

Reviews: