8
How to assemble Dispensing Sets for all milk containers:
standard ½ gallon plastic, refillable plastic container or
cardboard container
T
o ensure maximum sanitary conditions, please wear rubber gloves when
handling the disposable tubes.
Also, please prevent contact with the lower
section of the tube
.
Insert the long flexible or stainless steel tube into the extension of the plug.
Insert the plug with the tube into the spout of the container with the long
tube reaching down to the bottom of the milk container. The plug needs to
be positioned with the smaller hole at 12 o’clock and the raised hole at 6
o’clock.
How To Insert Dispensing Set into
the Refillable Plastic Container:
1. Unscrew lid from container.
2. Fill container with dairy product up to
the MAX Fill Line.
3. Screw on lid.
4.
Insert dispensing set for plastic
container with attached long tube into
opening in lid.
Insert the plug
assembly by positioning the smaller
hole at 12 o’clock and the raised hole
at 6 o’clock.
5.
The MILKchiller™ II can now be
loaded with Refillable Plastic
Container filled with dairy product.
How To Insert Disposable Dispensing
Set into
Standard Paper Half Gallon
Container:
1. Unscrew the cap.
2.
Insert plug for plastic container with
attached long tube into the pour spout.
Insert the plug assembly by positioning
the smaller hole at 12 o’clock and the
raised hole at 6 o’clock.
3.
The MILKchiller™ II can now be loaded
with a ½ gallon paper carton of dairy
product.